When connecting an electric motor to a gearbox (reducer), compatibility is sought at three points: the diameter, length and keyway of the motor shaft must suit the gearbox input bore; the flange type and spigot diameter of the motor flange must suit the gearbox adapter; and the motor's torque and speed must stay within the gearbox input limits. If any of these three does not match, the connection either does not seat at all or, even if it does, the key gets crushed, the shaft suffers fretting corrosion or the bearings fatigue early. Correct matching starts with the IEC frame number and ends by comparing flange type and shaft dimensions with the technical drawing.
How is the motor carried on a gearbox with an IEC adapter?
Most modern gearboxes come with an IEC adapter for direct motor mounting. One face of the adapter is bolted to the gearbox housing and the other to the motor flange; the motor shaft enters the gearbox's hollow input shaft or a coupling hub. In this arrangement the motor feet are often not used; the motor hangs on the gearbox and the gearbox is fixed to the machine. The motor feet stay idle here. The whole load passes through the flange.
The accuracy of the flange face and spigot therefore takes over the role that foot alignment plays on a foot-mounted motor. If the spigot diameter does not seat exactly in the adapter recess, the motor shaft stays eccentric to the gearbox input; the result is noise, heating and key wear. On large frames, for motors too long and heavy for the flange alone, an additional support foot or a foot-and-flange mounting arrangement is preferred. Centring is decisive here.
What decides the choice between a B5 and a B14 flange?
The gearbox adapter decides the choice. A B5 flange is wider than the motor frame and has through holes; the bolt passes from the back of the adapter and is tightened with a nut. A B14 flange is smaller and its holes are threaded; the bolt screws directly into the motor flange. For the same frame number the two flanges differ in spigot diameter and hole circle, so it must always be checked which flange the gearbox adapter is machined for.
B14 flanges may also come in different small and large sizes; gearbox catalogues state this distinction separately. Combined foot-and-flange arrangements (B34, B35) are used for motors that can be fixed both to the floor and to the gearbox. The catalogue states the distinction.
B3, B5, B14, B34, B35 and vertical V1/V3/V5/V6/V15 are offered depending on the frame; the flange size is confirmed when ordering.
You can compare dimensions on the 2D technical drawings by frame page.

How should the motor shaft seat in the gearbox input?
The shaft must enter the bore with the right tolerance and the key must sit without play. The gearbox input is usually a hollow shaft with a keyway inside. The motor shaft diameter must enter this bore with the right tolerance, the shaft length must not exceed the depth of the bore, and the key must sit without play in the slots of both the motor shaft and the gearbox bore. If the shaft is too long, it bottoms out before the motor flange meets the adapter; if it is too short, the key contact length drops and the key face gets crushed.
The most common mistake in assembly is driving the motor onto the gearbox with a hammer. The impact leaves marks on the bearing balls and soon comes back as noise. The right method is to clean the shaft and bore, apply an assembly paste that prevents fretting corrosion and pull the motor into place evenly with the flange bolts. No hammer is used here.
Checklist before assembly
- Confirm that the IEC frame number in the motor and gearbox catalogues is the same.
- Compare the flange type (B5 or B14) and the spigot diameter with the adapter.
- Match shaft diameter, shaft length and key size against the technical drawing.
- Check that the key length does not exceed the slot length in the gearbox bore.
- Decide the position of the terminal box and condensation drain holes according to the mounting direction.
How are motor torque and speed matched to the gearbox?
Motor torque is multiplied by the ratio and efficiency, and the result is compared with the gearbox limits. Motor shaft torque is found with T = 9550 · P / n, where P is in kilowatts, n is speed per minute and the result is in Nm. At the gearbox output, torque is approximately T_out ≈ T_motor · i · η, where i is the reduction ratio and η the gearbox efficiency. Output speed is calculated as n_out = n_motor / i. These formulas are general knowledge; confirm them with the gearbox manufacturer's selection table.
A hypothetical example: a 5.5 kW, 1460 rpm motor has a torque of about 36 Nm. On a helical gearbox with a ratio of 20 and an assumed efficiency of 0.95, the output torque is about 36 · 20 · 0.95 ≈ 684 Nm and the output speed 1460 / 20 ≈ 73 rpm.
The gearbox's permitted input power and output torque must stay above these values, and for shock loads an extra margin should be left according to the manufacturer's load class. To compare torque values quickly, see our electric motor torque table article.
| Check point | Motor side | Gearbox side | Symptom of a mismatch |
|---|---|---|---|
| Frame number | IEC frame (e.g. 112M) | IEC frame the adapter is machined for | Flange or shaft does not seat at all |
| Flange type | B5 or B14 | Adapter recess | Holes and spigot do not line up |
| Shaft and key | Diameter, length, key size | Input bore and slot | Crushed key, fretting dust |
| Torque | Rated torque | Permitted input torque | Gear wear, breakage |
| Speed | Speed depending on pole number | Permitted input speed | Oil heating, noise |
| Mounting direction | Horizontal or vertical arrangement | Oil level and breather plug | Oil leakage, seal damage |