How to Compare Dimensions When Ordering a B5 or B14 Flange Electric Motor

How to Compare Dimensions When Ordering a B5 or B14 Flange Electric Motor

The conversation that wastes the most time in flange motor orders goes like this: someone says "we need a B5" or "we need a B14", the motor arrives, and the flange does not fit the mating part. The problem is rarely the name of the mounting arrangement; it is the dimensions behind that name. This article walks through which dimensions you should ask for, which ones you should measure on site and what you should compare them with before ordering a B5 or B14 flange motor. We do not give figures; the dimensions for each frame are in the catalogue and the technical drawings, and the aim here is to ask the right questions in the right order.

Three-phase electric motor on a grey pedestal
Flange dimensions are taken from the mounting face on the motor's front end shield (representative image).

Where do B5 and B14 differ dimensionally?

In both arrangements the motor is attached to a gearbox, a pump or a machine housing through a mounting face on the front end shield. The difference is determined by where the bolt passes through:

  • B5 (large flange with through holes): The outer edge of the flange usually extends beyond the frame and carries holes that go right through. The bolt passes through the flange from the motor side and is fastened into a thread or nut on the mating part. In IEC designation this type is marked "FF".
  • B14 (face flange with tapped holes): The mounting face is smaller and stays within the outline of the frame. The holes are tapped blind holes; the bolt comes through the mating part and screws into the motor's front end shield. In IEC designation it is marked "FT".

This structural difference also changes how you measure. On a B5 the hole size is a clearance hole; on a B14 the hole size is a thread size and is read together with the thread pitch. In addition, more than one B14 size can be found on the market for the same frame; the distinction between a "standard" and a "large" B14 is one of the reasons why orders placed with the mounting name alone fail.

Dimensions that need to be compared

In catalogues and technical drawings, flange dimensions are given with letter codes. The list below sets out the items that should be confirmed from the old motor or the mating part before ordering:

Dimension (code on the drawing)What it describesWhat happens if it does not match
Flange outer diameter (P)The overall size of the mounting faceThe flange does not fit its seat or hits surrounding parts
Spigot diameter (N)The diameter of the register that centres the motor on the mating partThe shaft axis stays offset; bearings and gears are strained
Pitch circle diameter (M)The diameter of the circle through the centres of the bolt holesThe holes do not line up with the holes in the mating part
Number of holes and hole diameter / thread size (S)How many bolts are used and how thick they areThe bolt does not pass through or does not engage the thread
Spigot height (T)How far the spigot projects from the flange faceThe motor does not sit flat against the face, causing angular error
Shaft diameter (D) and shaft length (E)The thickness and length of the shaft end that transmits powerThe coupling, pulley or gearbox bush does not fit on the shaft or does not grip enough of it
Key width and key height (F, GA)The size of the keyway on the shaft and of the keyThe key does not seat in the keyway; torque transmission becomes unsafe

If even one of these seven items is different, the motor "almost fits"; on site this means an adapter plate, a bush or a machining job. Comparing all of them in one table before ordering is much cheaper than adapting afterwards.

Points to watch when measuring on site

If the old motor's nameplate is unreadable, or the motor has been replaced before and the original is unknown, you will have to take the measurements yourself. A few practical points help:

  • The pitch circle diameter is hard to measure directly. On a four-hole flange you can measure the distance between the edges of two opposite holes and add or subtract one hole diameter to arrive at the centre-to-centre distance. If the number of holes is different, evaluate the measurement together with the drawing.
  • On the spigot, the motor is male and the mating part is female. Measure the motor's register from the outside and the recess on the gearbox or pump side from the inside. The two values should be very close; a difference that looks small here still creates axis misalignment.
  • Verify the thread size of B14 holes with the bolt. Remove the old bolt and note its diameter and pitch. The depth of the blind hole also matters; a bolt that is too long can bottom out and fail to clamp the flange.
  • Clean the shaft end before measuring. Rust, paint or coupling residue makes the diameter look larger than it is. Take the shaft length from the flange face to the end of the shaft; remove the key and measure the keyway width separately.
  • Take photos. A clear photo of the flange from the front, of the shaft from the side and of the nameplate if there is one often reveals a typing error in the measurement table.

Prices and technical data are on the product pages; choose a model and order online.

How to match against the catalogue and drawings

Once you have collected the dimensions, make the comparison according to the motor's IEC frame code. The frame code (e.g. 112M) defines the shaft height and the frame length; the flange and shaft dimensions for that frame are in the HEM Motor technical and product catalogue and in the 2D technical drawings prepared per frame. For the general relationship between frame codes and power ranges you can also look at the IEC frame–power table.

At HEM Motor, the mounting arrangement is not listed per model on the product card. B3, B5, B14, B34, B35 and vertical V1/V3/V5/V6/V15 options are offered according to the frame; the flange size is confirmed with the order. So instead of writing only "B14" in the order note, add the flange outer diameter, spigot diameter, pitch circle diameter and hole details you measured. The available mounting arrangements are summarised in the mounting arrangements question.

Example: renewing a B14 flange pump motor (hypothetical)

The sequence below is a hypothetical example for illustration; it is not a real customer application. Suppose the 4 kW, 1,500 rpm motor on a circulation pump has failed and its nameplate is worn. The maintenance team knows only "4 kW B14".

  • Find the frame: For 4 kW and 4 poles, the HEM Motor range includes the 112M-4 model in a 112M frame. The first job is to roughly confirm, from the shaft height or the frame length, that the old motor was also in a 112 frame.
  • Measure the flange: Take the inner diameter of the recess on the pump side (spigot), the pitch circle diameter of the bolt holes, the number of holes and the bolt thread size. These values are compared with the 112 frame B14 dimensions in the catalogue.
  • Check the shaft: Measure the hub bore and keyway of the pump impeller or coupling and match them with the motor shaft dimensions.
  • Report the difference: If one of the dimensions does not agree with the catalogue, state this clearly before ordering; whether a suitable flange can be supplied is clarified with the technical team.

Models used in the examples

The three models below were chosen from the small and medium power range frequently found in flange applications. Flange dimensions are not written on this page; each must be read from the catalogue and the drawing according to its frame code.

  • 90L-4 aluminium frame: 1.5 kW (2 HP), 4 poles, 1,445 rpm, IEC 90L, 230/400 V (Δ/Y), 50 Hz, IP55, insulation class F.
  • 112M-4 aluminium frame: 4 kW (5.5 HP), 4 poles, 1,450 rpm, IEC 112M, 400/690 V (Δ/Y), 50 Hz, IP55, insulation class F.
  • 132S-4 aluminium frame: 5.5 kW (7.5 HP), 4 poles, 1,460 rpm, IEC 132S, 400/690 V (Δ/Y), 50 Hz, IP55, insulation class F.

Note the voltage line: the 90L-4 is rated 230/400 V, the other two 400/690 V. Even if the flange size matches, the connection (star or delta) on a 400 V supply is therefore different. Current prices are on the product pages.

Information to send with a flange motor order

To get the flange match right the first time, it is enough to send the following information in a single message:

  • Power (kW or HP) and speed (1,000, 1,500 or 3,000 rpm)
  • Mounting arrangement (B5, B14, B34, B35 or vertical) and the flange outer diameter, spigot diameter, pitch circle diameter, number of holes and hole/thread size you measured
  • Shaft diameter, shaft length and key size
  • Supply voltage and starting method
  • The equipment the motor will be connected to (pump, gearbox, fan) and the operating environment
  • A photo of the old motor's nameplate and photos of the flange and shaft

Review suitable models and current prices on the buy electric motors page. If you send the dimensions and the nameplate photo through the motor nameplate submission page or our contact page, we can check the flange match together.

HEM Motor Models Related to This Article

The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.

1.5 kW 1500 rpm Aluminium Frame Electric Motor 90L-4

90L-4

1.5 kW · 1500 rpm

  • Aluminium frame · IEC 90L
  • 1445 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame — confirmed with the order

US$136.71 (€122.01)

View product
4 kW 1500 rpm Aluminium Frame Electric Motor 112M-4

112M-4

4 kW · 1500 rpm

  • Aluminium frame · IEC 112M
  • 1450 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame — confirmed with the order

US$241.27 (€215.32)

View product
5.5 kW 1500 rpm Aluminium Frame Electric Motor 132S-4

132S-4

5.5 kW · 1500 rpm

  • Aluminium frame · IEC 132S
  • 1460 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame — confirmed with the order

US$324.39 (€289.49)