When choosing an electric motor for the plastics and packaging industry, the first thing to look at is the machine's load profile: an extruder screw needs high, continuous torque at low speed, a granulator or shredder sees impact loads and heavy starts, and the hydraulic pump of an injection moulding machine works with pressure that changes throughout the cycle. Power is set by this load, speed by the gearbox or pump requirement, and frame and protection options by the heat, dust and cooling-water conditions in the hall. Below we take each station of the line, from granules to the finished carton, through these three questions.
Why does every station from granules to cartons need a different electric motor?
Each station has a different load, speed and duty, so a single motor type is not enough.
In a typical plastics processing plant, raw material travels from the silo to the machine via vacuum conveyors and dosing units. The extruder or injection moulding machine shapes the product, flash and rejects are recovered in the granulator, and the moulds and barrel are cooled by chiller pumps. On the packaging side there are film wrapping, filling, bag sewing, carton taping and pallet stretch wrapping machines.
Each of these stations calls for its own selection logic. In the same plant, a 37 kW extruder drive stands next to a 1.5 kW carton taping motor; efficiency and continuous torque matter for one, frequent stop-start and compact mounting for the other. You can see suitable power ranges for the sector together on the plastic and rubber processing motors page.
How are power, speed and gearbox matched for an extruder screw?
In an extruder, the electric motor usually turns the screw through a gearbox; screw speed ranges from a few tens to a few hundred revolutions per minute. The motor is therefore mostly chosen as a four-pole unit with a synchronous speed of 1500 rpm, and the gear ratio is set according to the required screw speed. Melt pressure and material viscosity directly increase the torque demand; on lines processing rigid PVC or filled compounds, a screw of the same diameter draws more power than on a polyolefin line.
Most extruders are driven by a frequency converter, because output is adjusted through screw speed. Our three-phase series are suitable for this kind of drive. If the screw turns for long periods at low speed and high torque, the motor's own shaft-mounted fan becomes weak; in that case a separately powered cooling fan is considered. If the cable between converter and motor is long, a dv/dt or sine filter is evaluated; the operating speed range and cable length should be stated with the order.
When the extruder stops, material cooling in the barrel loads the screw at the next start. Starting before the heater zones reach set temperature strains both motor and gearbox, so start permission should be linked to temperature control.
For motors to be coupled to a gearbox, the electric motors for gearboxes page summarises the connection options.
Why are the granulator and shredder considered heavy-start loads?
In a plastic granulator, the rotating knives are attached to a heavy rotor with high inertia. At start-up the motor has to accelerate not only the knives but this whole mass. Run-up time lengthens. The winding carries high current during it. Starting with parts still in the hopper increases the load further. For this reason, when sizing a granulator motor, the starting condition is discussed as much as the rated power.
A shredder, by contrast, is a low-speed, high-torque machine that reverses frequently. When it detects a jam, it backs off and then drives forward again. This stop-start-reverse cycle causes heat build-up in the motor, and the PTC or PT100 sensor option can be requested with the order to monitor winding temperature. In the granulating and grinding area, airborne plastic dust settles on the fan cover grille; standard IP55 protection guards the interior, while the outer surface must be cleaned regularly.

What does the hydraulic pump of an injection moulding machine expect from the electric motor?
On a conventional hydraulic injection moulding machine, the electric motor turns a hydraulic pump whose pressure changes through the mould closing, injection, holding and cooling phases. The motor runs continuously throughout the cycle. Its load, however, rises from low to high within seconds. The pump's flow rate and maximum pressure are the two basic figures that determine motor power; these values should be taken from the machine manufacturer's hydraulic diagram.
There is usually a coupling and a bell housing between pump and motor, so the mounting is mostly flanged. Foot, flange and vertical options vary with frame size and the flange size is confirmed with the order; shaft and flange values need to be compared with the technical drawings by frame size.
You can find power ratings suited to hydraulic units on the electric motors for hydraulic pumps page.