On a scrap metal separation belt the electric motor is chosen by the shaft power the belt load requires and by the type of magnet unit; a magnetic head pulley adds load to the belt's own drive, while an overband magnet has its own motor that is sized separately from the main belt motor. Placing the motor away from the magnetic field and protecting it from iron dust are also part of the selection.
Which magnet units on a separation line affect the motor?
Three types of unit are common in scrap and recycling plants. Each gives the motor a different job.
- Magnetic head pulley. The pulley at the drive end of the belt is permanently magnetised. Ferrous pieces stick to the pulley and drop under the belt. The motor turning the pulley is the belt's main drive motor.
- Overband magnet. A separate unit above the belt, crosswise or in line with it. It throws captured iron to the side with its own short belt; that short belt has its own drive group.
- Eddy current separator. Separates non-ferrous metals such as aluminium and copper. It has a fast-spinning magnetic rotor; rotor and belt are usually driven by two separate motors, often on frequency converters.
Order a motor without this distinction and the wrong frame arrives.
How is motor power found on a belt with a magnetic pulley?
In a belt drive, shaft power comes from the peripheral pull force at the pulley multiplied by belt speed; gearbox and bearing losses are added:
Pshaft ≈ Fperiph × v / ηgearbox
Fperiph is made up of the friction of load and belt on the carrying idlers, the force needed to lift the load on an inclined belt and the resistance of scrapers. Detailed calculation of these items for belt conveyors is given in sources such as DIN 22101 (general information; confirm with the machine manufacturer).
A magnetic pulley adds two things to this calculation. The first is weight; a permanent magnet pulley is clearly heavier than a steel pulley of the same diameter, and a larger inertia must be accelerated at start. The second is the extra resistance created when ferrous pieces stuck to the pulley are scraped off under the belt.
Hypothetical example: on a horizontal separation belt running at 0.8 m/s, peripheral force is calculated as 5 kN. Shaft power is 5000 × 0.8 = 4 kW; with a gearbox efficiency of 0.9, about 4.4 kW is needed at the motor shaft. In this case the 5.5 kW step leaves a margin for starting the heavy pulley and restarting with a loaded belt. The current and torque difference between steps can be compared on the electric motor sales page.
Why is the overband magnet's motor chosen separately from the main belt?
The overband unit's belt is short and light; the only load it carries is the captured iron. Motor power is therefore small, but the operating condition is harsher than the main belt's: the motor sits right next to the magnet, where iron dust is dense.
This unit's motor is usually a geared drive chosen by the magnet manufacturer. On replacement, plate power, speed and flange size should be kept; if the gearbox output speed changes, the speed of the discharge belt and therefore the point where iron is released also change.
If the overband magnet is an electromagnet it has a separate DC supply. This supply is independent of the motor circuit and outside the scope of this article; only where both circuits share a panel is the control sequence (belt motors first, then the magnet) checked.
How do the magnetic field and iron dust affect the motor?
A strong permanent magnet attracts nearby steel parts; motor frame, fan cover and shaft are among them. Moving the motor outside the influence zone of the magnetic pulley or overband magnet is the first measure that can be applied on site. Magnet manufacturers usually give this distance or a stainless/non-magnetic zone boundary in their documents (general information; confirm with the machine manufacturer).
The second problem is iron dust. Fine iron particles stick to the grille and between the fins. As they build up the air path narrows; the winding runs a few degrees hotter even at unchanged load.
Check this every week.
Two checks are enough on site. With an infrared thermometer, motor frame temperature is compared with a clean and a dirty fan cover. If the difference is clear, the cleaning interval is shortened or the motor is relocated out of the dust flow.
An IP55 frame protects the inside. The layer building up outside is removed only by regular cleaning; because compressed air spreads iron dust around, a brush and an industrial vacuum are preferred.