Electric Motor for a Corrugated Board Line: Line Speed and Auxiliary Drives

Electric Motor for a Corrugated Board Line: Line Speed and Auxiliary Drives

When choosing electric motors for a corrugated board line, two groups are thought about separately: the main drives that carry line speed and the many auxiliary drives around them. For the main drives, the job is converting the line's speed in metres per minute correctly into drum and roll speed, then into gearbox and motor speed, and running all sections in sync with each other. The auxiliary motors are small but numerous; there, frequent stop-start, frequency converters and ambient conditions guide the choice.

Which drives are found on a corrugated board line?

A typical line is a long chain stretching from the reel stands to the stacker. Each section has motors with a different load character. They are not alike.

SectionDrive dutyLoad character
Reel stand and preheaterPaper tension, reel liftingLow power, frequent positioning
Single facer (fluting)Corrugating rolls, pressure rollContinuous, tied to line speed
Bridge and glue unitBridge belts, glue rollVariable speed, light load
Double facer (hot plates)Upper and lower traction beltsThe most heavily loaded continuous drive of the line
Slitter scorerKnife and scoring discs, positioningShort duty, frequent position changes
Cut-off knife and stackerCross cutting, stacking beltsAcceleration and deceleration cycle
AuxiliariesGlue pumps, vacuum fans, extraction, steam condensate pumpsContinuous, fixed speed

Sections needing dynamic positioning, such as slitting and the cut-off knife, often run on servo or specially driven motors. These duties need a special motor; they may fall outside the standard range in HEM Motor's 2026 catalogue, so ask us with the nameplate and application details.

How is line speed converted into motor speed?

The calculation starts from belt or roll diameter. Roll speed = line speed / (π × diameter); the ratio between motor speed and roll speed is provided by the gearbox and pulley arrangement (general information; go by the values the line manufacturer gives).

A hypothetical example: say the double facer traction drum is 0.5 m in diameter and the target line speed is 200 m/min. Drum speed comes to 200 / (3.14 × 0.5) ≈ 127 rpm. A 4-pole motor turning at 1460 rpm reaches that through a gearbox of roughly 11.5. If the line is to go up to 250 m/min, the motor is taken slightly above 50 Hz with the converter, or the gearbox ratio is chosen for it from the start.

Speed does not stay fixed. As paper grammage, glue drying time and board type change, the operator slows the line down or speeds it up. So the motor is chosen to run across a speed range, not at one speed. If full torque is needed at the bottom of the range, cooling must be considered separately. The rated speeds to use when calculating the gearbox ratio are written for every model on our shop page.

Why does synchronisation between sections matter so much?

The paper moves as one web from the single facer to the double facer. A small difference is enough. If one section turns slightly faster than another, the paper tightens and breaks; if it lags, sagging and waving appear on the bridge. The glue line is sensitive to this difference too, and blistering and poor bonding show up in the board.

That is why the main sections are driven through frequency converters from a common speed reference. The converters take the same speed command from the line PLC; small corrections are made from tension and dancer roll signals. On the motor side what is expected is that slip is known and the nameplate data is entered correctly into the drive.

Our three-phase ranges are suitable for speed control with a frequency converter; for long running at low speed with full torque a separate fan may be needed; if the drive-to-motor cable is long, a dv/dt or sine filter is considered; these conditions are stated when ordering. On corrugating lines the distance from panel to motor is often long, so filters come up frequently in these plants.

Electric motor running on a paper and board converting machine
On a corrugated board line the main drives run from a common speed reference, while auxiliaries mostly run at fixed speed (representative image).

Prices and technical data are on the product pages; choose a model and order online.

What should be checked when choosing auxiliary drive motors?

A corrugating line has dozens of small and medium motors. Individually they look cheap. But when one burns out the whole line waits; so spares strategy and standardisation matter as much as efficiency class.

  • In glue pumps, starch glue is viscous and thickens as it cools. Load can rise at the first start in the morning, and the motor is chosen with a margin for that.
  • Vacuum and extraction fans turn all day and draw a load that rises with the square of speed. Lowering frequency when less air is needed shows up straight away on the electricity bill.
  • Condensate and hot water pumps work near the hot plates at high ambient temperature. Frame temperature and insulation class matter here.
  • After the stacker, the belts carrying the sheets stop and start often. The number of starts per hour determines how hot the motor gets.

Standardising motors in the same frame and power makes holding spares easier. The frame number is the first piece of compatibility information; foot, flange and shaft dimensions are compared from the technical drawings.

Which ambient and maintenance conditions are hardest?

In a corrugated board plant, the three things that strain a motor most are paper dust, heat radiating from the hot plates and moisture from the steam line. Paper dust is fine and light; it builds up on the fan grille and fins and reduces cooling.

Our standard range is IP55 with class F insulation. For motors around the double facer, measuring frame temperature regularly when ambient temperature rises and keeping the fins clean is the simplest way to protect winding life. Where there are steam leaks, the tightness of the terminal box cover also goes on the checklist.

Vibration measurement should be in the maintenance plan too. On long traction belts, belt tension and drum bearings put extra load on the motor; a slow rise in bearing temperature usually comes from belt alignment.

Which HEM models suit a corrugated board line?

Examples from steps often seen from auxiliary drives up to the main sections:

  • 90L-4: cast iron, 1.5 kW, 1445 rpm, 3.30 A at 400 V, 9.91 Nm. For glue mixers, small transfer belts and condensate pumps.
  • 132M-4: cast iron, 7.5 kW, 1460 rpm, 14.3 A at 400 V, 49.1 Nm. For vacuum fans and bridge drives.
  • 180M-4: cast iron, 18.5 kW, 1470 rpm, 33.5 A at 400 V, 120.2 Nm. For single facer and double facer traction drives.

The real power comes from the figure the line manufacturer gives for speed and board width. Notes for the packaging sector are on the packaging machine motors page and the standard range on our industrial motor page. All power steps and prices are on our shop page.

If you send the list of motors on your line and nameplate photos via our nameplate replacement finder page, we will work out suitable steps for standardisation and spares together. Other models are on the HEM Motor sales page.

Frequently Asked Questions

Which pole count is common for the main drives?

On most lines, 4-pole. The 1500 rpm class comes down to drum speed through a medium-sized gearbox and runs across a wide speed range with a converter.

Does raising line speed require changing the motor?

Not always. The motor can be taken slightly above 50 Hz with a converter; but torque then falls, and the available power margin must be checked by calculation.

Does efficiency class matter for auxiliary motors?

For fans and pumps that turn all day, yes. For belts that stop and start often, correct sizing and number of starts are more decisive.

How risky is paper dust for the motor?

The main risk is reduced cooling. If the fins are cleaned regularly, an IP55 motor runs comfortably in a normal dusty environment.

HEM Motor Models Related to This Article

The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.

1.5 kW 1500 rpm Cast Iron Frame Electric Motor 90L-4

90L-4

1.5 kW · 1500 rpm

  • Cast iron frame · IEC 90L
  • 1445 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$141.37 (€129.38)

View product
7.5 kW 1500 rpm Cast Iron Frame Electric Motor 132M-4

132M-4

7.5 kW · 1500 rpm

  • Cast iron frame · IEC 132M
  • 1460 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$387.29 (€354.46)

View product
18.5 kW 1500 rpm Cast Iron Frame Electric Motor 180M-4

180M-4

18.5 kW · 1500 rpm

  • Cast iron frame · IEC 180M
  • 1470 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$856.68 (€784.05)

View product

Similar Articles