When choosing an electric motor for a feed dosing screw, the real goal is for every turn of the screw to carry the same amount at low flow; to achieve this, before moving on to motor power, the gearbox ratio, the lowest frequency the motor may run at and the torque required at start are decided together. Because flow is proportional to screw speed, the motor's ability to turn at low speed without slipping or overheating is the basis of feeding stability.

What does flow depend on in a dosing screw?

The volume a screw carries is the amount the space between the flights advances in one turn multiplied by the number of turns per minute. That is why the most direct way to adjust flow is to change screw speed.

Volumetric flow is calculated approximately as Q = (π/4) × (D² − d²) × s × φ × n. Here D is the screw outer diameter, d the shaft diameter, s the pitch, φ the fill factor and n the speed per minute. The fill factor depends on the product's flowability, the screw's inclination and the feed hopper design; the correct value comes from the machine manufacturer or a calibration weighing (general information; confirm with the machine manufacturer).

On site the formula means something simple: if speed halves, flow roughly halves too. If speed is unstable, so is flow.

Hypothetical example: how does the speed range determine flow?

The values below are hypothetical and were chosen to show the method. A screw outer diameter of 100 mm, shaft diameter of 30 mm, pitch of 100 mm, fill factor of 0.4 and feed bulk density of 0.6 t/m³ are assumed.

Screw speedVolumetric flowMass flow
10 rpm≈ 0.17 m³/h≈ 0.10 t/h
20 rpm≈ 0.34 m³/h≈ 0.21 t/h
40 rpm≈ 0.69 m³/h≈ 0.41 t/h

The volume carried per turn is about 0.000286 m³. A range between 10 and 40 rpm changes flow by up to four times. If the recipe contains small additives, the lower end becomes even more important.

The real question is which frequencies this range corresponds to on the motor side. If a six-pole motor running at 935 rpm at mains frequency is connected to a 40 rpm screw speed through a gearbox of about 23.4 ratio, the motor runs at around 12.5 Hz for 10 rpm. The shop page can be used to view power and speed steps side by side.

Why does the motor struggle at low frequency?

A screw is a constant-torque load: even when speed drops, the torque needed to push the feed hardly decreases. The motor, however, is cooled by a fan fitted to its own shaft; as the shaft slows, the cooling air weakens too. The result is that a motor running at full torque at low frequency for long periods heats up. Even if winding temperature does not exceed its limit, insulation life is shortened. This is solved in one of two ways: either the gearbox ratio is increased to raise the motor's lowest operating frequency, or a separate fan running independently of the motor's speed is added. Our three-phase series are suitable for speed control with a frequency inverter; long operation at low speed with full torque may require a separate fan; if the drive-to-motor cable is long, a dv/dt or sine filter is considered; these conditions are stated with the order.

Choosing the ratio is a balance. As the ratio grows, the motor turns faster and cooler, but reaching the upper flow may require going above 50 Hz; in this region the torque the motor can deliver decreases.

Why does feeding fluctuate if speed does not stay constant?

When load rises, the speed of an asynchronous machine drops slightly; this difference is called slip. As the level in the feed hopper changes, the load seen by the screw changes too, motor speed varies by a few percent and flow shifts by the same proportion.

Slip compensation or vector control mode in frequency inverters largely corrects this deviation. If tighter accuracy is required, an encoder is fitted to the motor shaft and closed-loop speed control is set up; encoder mounting is specified at the start of motor selection.

There is also mechanical pulsation.

A single-flight screw drops a heap at the outlet once every turn. At low speed this pulse becomes noticeable. A double-flight screw or a smaller pitch smooths the output. This is a screw design issue, not a motor one, but on site it is often blamed on the motor.

Prices and technical data are on the product pages; choose a model and order online.

Why does the screw jam at start-up?

In a screw standing between shifts, feed packs between the flights; with moist or oily additive recipes this packing turns into caking. The first start demands much higher torque than continuous running. With a frequency inverter the start ramp and starting torque boost are adjusted. On screws connected directly to the mains, the motor's starting torque is compared with the catalogue value. If the overload relay trips often during start-up, bridging at the hopper outlet is checked before motor power.

On dosing lines working in batches, the motor stops and starts many times an hour. The number of starts per hour and the duration of each batch should be stated with the order; frequent starts add directly to the motor's thermal load.

Electric motor driving a screw conveyor
In a screw drive, the geared motor keeps its torque while turning slowly (representative image).

How are mounting and environmental conditions handled?

Dust is everywhere in feed plants. If the fan cover air inlet and housing fins are coated with dust, cooling drops; regular cleaning becomes even more important for motors running at low frequency. A screw motor is often connected to a gearbox flange. B3, B5, B14, B34, B35 and vertical V1/V3/V5/V6/V15 are offered according to frame; the flange size is confirmed with the order. On vertical or inclined screws, the motor position and the direction the terminal box will face are decided at the very start.

Areas classified as explosive dust atmospheres are a separate matter; the certification of a motor used there is chosen according to the plant's zone classification and written clearly in the order.

Which HEM Motor motors can be considered for a feed dosing screw?

Three steps from the six-pole aluminium frame series often used with a gearbox on low-flow dosing screws: 80M2-6 (0.55 kW; 890 rpm; 5.9 Nm; 1.43 A at 400 V), 90S-6 (0.75 kW; 935 rpm; 7.66 Nm; 1.93 A) and 90L-6 (1.1 kW; 945 rpm; 11.1 Nm; 2.69 A). These models are 230/400 V, IP55 with class F insulation.

For a wider power range see the general purpose industrial motors and asynchronous electric motors pages.

If you send the screw diameter, pitch, required lower and upper flow, feed bulk density and number of batches per hour through our contact page, we will set the gearbox ratio and motor power together while respecting the low-frequency limit. For current prices, the HEM Motor product list can be opened.

Frequently Asked Questions

How do you decide between a four-pole and a six-pole motor for a dosing screw?

A six-pole motor reaches the same screw speed with a lower ratio; at the same power its rated torque is also higher than a four-pole motor's. The decision is made by calculating the ratio and the lowest frequency the motor may run at together.

Can the motor run continuously below 10 Hz?

Under constant-torque load, a motor cooled by its own fan may overheat at this frequency. The solution is either to add a separate fan or to increase the ratio and raise the operating frequency.

Why does flow change during the day?

Hopper level, feed moisture and bridging change the screw's fill factor. Even if motor speed stays constant, flow changes when fill changes; that is why weighing feedback is often used.

What can be done if the screw leaves too much feed at the end of a batch?

The stop ramp can be shortened or the need for a brake assessed. A brake requirement is stated with the order.

HEM Motor Models Related to This Article

The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.

0.55 kW 1000 rpm Aluminium Frame Electric Motor 80M2-6

80M2-6

0.55 kW · 1000 rpm

  • Aluminium frame · IEC 80M
  • 890 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$100.15 (€91.66)

View product
0.75 kW 1000 rpm Aluminium Frame Electric Motor 90S-6

90S-6

0.75 kW · 1000 rpm

  • Aluminium frame · IEC 90S
  • 935 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$102.89 (€94.16)

View product
1.1 kW 1000 rpm Aluminium Frame Electric Motor 90L-6

90L-6

1.1 kW · 1000 rpm

  • Aluminium frame · IEC 90L
  • 945 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$128.89 (€117.97)

View product

Similar Articles