Switching to IE3 and IE4 Electric Motors in Greenhouses

Switching to IE3 and IE4 Electric Motors in Greenhouses

In greenhouse growing, the move to IE3 and IE4 electric motors should begin with the heating circulation pumps that run day and night all winter, followed by the exhaust fans that run for long hours in summer. Irrigation and fertigation pumps, together with short-duty drives such as screens and vents, go to the bottom of the list, because the difference between efficiency classes is only felt when a motor runs for many hours a year. Below, a greenhouse motor inventory is ranked according to its operating calendar, and the points to check during the changeover are covered one by one.

Why does efficiency class depend on the season in a greenhouse?

A motor in a factory runs at the same pace for most of the year. In a greenhouse, every motor has its own season. The circulation pump in the boiler room hardly ever stops from October to April. The exhaust and pad cooling side runs at full load around midday between May and September. The drip irrigation pump switches on in several short cycles every day, while the roof vent motor moves for a few minutes a day.

The difference between IE3 and IE4 is a reduction in the motor's own losses; during the hours the motor stands still, that difference is worth nothing. So the changeover decision in a greenhouse starts with a single question: how many operating hours does this motor have per year, and what is its load during those hours?

How is the greenhouse motor inventory ranked by operating hours?

DriveWhen does it run?Changeover priority
Heating system circulation pumpsContinuously throughout the heating seasonHigh; first replacement candidate
Exhaust and ventilation fansLong daytime hours in summer, partly in the shoulder seasonsHigh; assessed as a batch when there are many fans
Pad cooling and fogging pumpsAfternoons on hot daysMedium
Irrigation and fertigation pumpsSeveral short cycles every dayMedium to low; replaced when a fault or rewind is due
Screen, roof vent and bench drivesA few minutes a dayLow; efficiency class is not decisive

When drawing up the table for your own greenhouse, write each motor's nameplate rating, approximate daily running time and number of operating months on a single page. In modern soilless greenhouses that crop all year round, the hours are markedly higher than in conventional greenhouses.

Why are boiler room pumps the first candidates for replacement?

In greenhouses with hot-water heating, the pumps circulating water between the boiler or heat pump and the pipe rails run continuously throughout the heating season. If a pump stops on a cold night, the pipe temperature drops quickly and there is a risk of frost damage or crop loss. The motors of these pumps are usually 2-pole and rated at a few kilowatts; since they run several thousand hours a year, the effect of efficiency class shows up most clearly here.

Do not leave the motor replacement on the heating pump until the season starts. In September or early October, before the boiler is commissioned, the old motor's winding resistance and bearing noise are checked; a motor that looks weak is replaced with a more efficient model at this stage. Models suitable for pump drives are also listed in the agricultural machinery motors group prepared for farm applications.

How is the annual difference calculated for exhaust fans?

Assume a medium-sized greenhouse has 40 exhaust fans on its side wall, each with a 1.1 kW motor. Let the fans run about 2,000 hours in total over the summer months. If the motor runs close to full load, a motor with, for example, 84 percent efficiency draws about 1.31 kW from the grid, while a motor with 86.5 percent efficiency draws about 1.27 kW.

The difference of roughly 0.04 kW amounts to around 75 kWh per fan over 2,000 hours, and about 3,000 kWh a year across 40 fans. The efficiency values here are purely illustrative; in your own calculation use the efficiency from the motor nameplate or catalogue and the fans' actual running hours.

The figure looks small for a single fan, but the case for a batch changeover grows as the number of fans in the greenhouse increases.

Electric motor driving an exhaust fan on a greenhouse side wall
Greenhouse ventilation fan electric motor (representative image).

Why can a more efficient motor change the fan's airflow?

Motors in higher efficiency classes usually have less slip, which means the speed can be slightly higher for the same number of poles. As fan speed rises, airflow rises too, but the power drawn by the fan climbs much faster with speed. This is a general engineering principle; please confirm with the fan manufacturer.

In short, after the motor is changed the fan moves a little more air and asks for a little more power. If the old motor was already running at its limit, the new motor's current should be measured on the first hot day. On belt-driven fans the speed can be brought back to its old value through the pulley ratio; on direct-coupled fans the decision is made on the basis of the measurement.

Fan drives used in agricultural buildings such as greenhouses and barns are collected under ventilation motors.

Prices and technical data are on the product pages; choose a model and order online.

What should be checked for humidity, fertiliser vapour and rural grids during the changeover?

Greenhouse air is warm and humid. Condensation can form on the motor frame in the morning hours. There is corrosive vapour around the fertigation unit. The basic equipment of the series is IP55 with class F insulation. For pump points that are hosed down or splashed, IP56 protection can be ordered, and for long idle periods between seasons, an anti-condensation heater against moisture building up in the frame.

Voltage fluctuations and long cables are common on rural lines. Choose the new motor's connection according to the grid: on smaller ratings the nameplate may read 230/400 V, on larger ratings 400/690 V. If you want to drive fans and pumps with a frequency converter, our three-phase series are suitable for this kind of speed control; a fan motor that will turn slowly but at full load for long periods during the night may need a separately powered fan, and if the panel is at the far end of the greenhouse, a dv/dt or sine filter is considered because of the cable length. Simply write these details into the order.

Submersible pumps that go down into a borehole are a task that requires a special motor; as this may fall outside the standard range in HEM Motor's 2026 catalogue, send us the borehole motor's nameplate and the well details.

How is the new motor fitted in place of the old one?

The first thing checked when matching is the IEC frame number, because when the efficiency class goes up the frame length can change on some ratings. Then whether it is foot- or flange-mounted, the shaft diameter and length, the spacing of the foot holes, the flange type and the electrical values on the nameplate are placed side by side with the old motor. Foot-mounted B3, flange-mounted B5 and B14, combined B34 and B35 and vertical V1, V3, V5, V6, V15 options depend on frame size; the flange dimension is finalised at the ordering stage.

For numerical dimensions, refer to the catalogue and technical drawings. When mounting on a pump base at the edge of the greenhouse, coupling alignment is also checked again.

Which IE-class electric motors can serve as examples for greenhouse drives?

The models below are a starting point for typical greenhouse tasks; the actual power should be matched with data from the fan or pump manufacturer. You can review other power and pole options by efficiency class in our product shop.

  • For side-wall exhaust fans, the 1.1 kW, 4-pole aluminium-frame 90S-4 can be considered; its rated speed is 1445 rpm and its voltage 230/400 V.
  • For a drip irrigation or fertigation pump, the 1.5 kW, 2-pole aluminium 90S-2 is worth considering; it runs at 2895 rpm.
  • For a heating circuit circulation pump, the 4 kW, 2-pole aluminium 112M-2 is a suitable candidate; its rated speed is 2905 rpm and its voltage 400/690 V.

When is the best period for the changeover in greenhouses?

For greenhouses the most sensible changeover window is the period from late summer to the start of the heating season: pumps are replaced in this window, while fans are renewed one after another over the winter months and are ready before the spring heat arrives. To pin down which motor to renew, you can send nameplate photos of your current fan and pump motors via the find-an-equivalent-from-nameplate page; our team will work out the suitable IE class and frame for each one. While completing your greenhouse list, you can filter the other fan and pump ratings you need by number of poles in the HEM Motor shop.

Frequently Asked Questions

Should I replace the fans or the heating pumps first in a greenhouse?

The circulation pumps that run continuously through the heating season are usually the first candidates. If there are many fans, they are assessed as a batch in the second stage.

Does it make sense to move to IE4 on roof vent and screen motors?

These drives run for a few minutes a day, so the difference between efficiency classes is hardly noticeable in practice. They do not need replacing unless they fail.

After fitting a new motor, the fan draws more current; is that normal?

A motor with less slip can speed the fan up slightly. Measure the current; if it is close to the nameplate value, the pulley ratio can be corrected on belt-driven fans.

Does greenhouse humidity harm IE-class motors?

Efficiency class does not change moisture resistance. Look at the protection class, condensate drainage and, if necessary, the anti-condensation heater option.

HEM Motor Models Related to This Article

The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.

1.1 kW 1500 rpm Aluminium Frame Electric Motor 90S-4

90S-4

1.1 kW · 1500 rpm

  • Aluminium frame · IEC 90S
  • 1445 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$116.16 (€106.32)

View product
1.5 kW 3000 rpm Aluminium Frame Electric Motor 90S-2

90S-2

1.5 kW · 3000 rpm

  • Aluminium frame · IEC 90S
  • 2895 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$111.78 (€102.31)

View product
4 kW 3000 rpm Aluminium Frame Electric Motor 112M-2

112M-2

4 kW · 3000 rpm

  • Aluminium frame · IEC 112M
  • 2905 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$211.25 (€193.34)