How Can the Energy Cost of Electric Motors Be Reduced in Dairy Plants?

How Can the Energy Cost of Electric Motors Be Reduced in Dairy Plants?

In dairy plants, the energy cost of electric motors is reduced by first measuring the ice water and cooling circuit and the homogeniser, which account for most of the consumption, then cutting the hours these drives run needlessly, adding speed control to pumps and fans whose flow varies, and replacing motors that are due for renewal with the right power and efficiency class. Every step from milk reception to the filling machine needs cooling, heating and pumping; that is why savings in a dairy come not from one large investment but from smartly adjusting the operating pattern of many drives. Below we take the electric motors of a milk processing plant in process order.

Which drives stand out on a dairy's electricity bill?

On the journey that starts at the raw milk reception tank, milk is first cooled, then heated and cooled again in the pasteuriser, separated from its cream in the separator, passed through the homogeniser and, depending on the product, sent to yoghurt incubation, the cheese vat or the filling machine. After each product the lines are cleaned by CIP. In this flow, the drives that draw the most electricity are usually the ice water compressors and pumps, the homogeniser, the condenser and cooling tower fans, the separator and the CIP pumps.

The power of an electric motor alone does not show the bill; what matters is power multiplied by annual running hours. A 7.5 kW ice water pump turning all night can log more kilowatt-hours than a 30 kW butter churn running two hours a day. So the first task is to rank the motor list not by power but by estimated annual consumption.

Dairy driveTypical operating patternEnergy opportunity
Ice water compressor and circulation pumpLong hours, also running at nightIce bank, night tariff, pump speed control
HomogeniserHigh load throughout productionPressure by recipe, cutting idle running
SeparatorLong start, continuous rotationAvoiding needless rotation between runs
CIP supply and return pumpAt every product changeStep-based flow, speed control
Cooling tower and condenser fanVaries with seasonFan speed linked to water temperature

Where is energy wasted in the ice water circuit?

The losses come from a compressor running at daytime peak hours, from excess ice and from a pump circulating for nothing. In dairy plants, ice water at around 1–2 °C is sent to the plate cooler and the tanks. In many dairies this need is met by an ice bank: the compressor runs at night on the cheaper tariff, ice builds up on the coils, and during the day this ice is melted to provide cooling during milk reception and pasteurisation. In plants without an ice bank, the compressor has to run at full load during daytime peak hours.

Correct setting of the ice thickness sensor prevents ice from being built thicker than necessary; excess ice keeps the compressor running for long periods at low suction pressure, in an inefficient zone. The circulation pump also often keeps turning at full speed while consumers are closed. If a frequency converter is fitted to this pump and speed is linked to line pressure, the amount of water pumped for nothing overnight and at weekends falls noticeably; since pump power drops quickly with speed, even a small speed reduction shows on the bill (general information; confirm with the pump manufacturer).

How can the homogeniser's energy use be reduced?

By using the minimum pressure each product needs and cutting idle running. The homogeniser is a high-pressure piston pump and carries one of the largest single electric motors in a dairy. The power it draws is directly related to the product of flow and homogenising pressure. Using the same high pressure for every product, for example applying more pressure than needed for cheese milk or certain yoghurt recipes, means the motor spends extra energy with no product benefit.

Setting the minimum pressure required for each product together with the quality team and writing it into the recipe is a step that needs no investment. The second step is to stop the homogeniser running idle while the pasteuriser is circulating water or while the filling machine is waiting; during these periods the pressure head can be opened or the machine stopped. When the production sequence is arranged so that the homogeniser motor makes planned stops instead of frequent stop-starts, both energy and mechanical life benefit. Writing pressure into the recipe costs nothing.

Which hours are overlooked on separator and pasteuriser pumps?

The idle hours between production runs and while the line circulates water are the ones overlooked. The bowl of a cream separator rotates at high speed and takes minutes to reach full speed. Because of this long start, operators do not want to switch the separator off between runs, and the bowl spins idle for hours.

The start time requires the motor and its protection to be chosen for this heavy start; selection should be based on the start time and inertia data given by the separator manufacturer. If the production plan runs the separator in grouped batches, idle rotation hours become shorter.

The hot water circuit pump and the milk feed pump in the pasteuriser likewise turn at full speed while the line circulates water. Fouling of the regeneration section reduces heat recovery; steam and ice water demand rises, indirectly increasing the load on compressor and pump motors. Regular CIP of the plates and periodic opening and inspection are therefore an electrical matter as well. You can see power ranges for milk and utility fluid pumps on the pump electric motors page.

Pump electric motor feeding the ice water circuit in a dairy plant
Pump electric motor in an ice water and chiller circuit (representative image).

Why should pump speed be adjusted across CIP steps?

Because each CIP step needs a different flow. In a dairy plant, CIP is a cycle that runs many times a day and each time goes through pre-rinse, caustic, intermediate rinse, acid and final rinse steps. In tank cleaning the spray balls require a certain flow, while in pipe cleaning the flow velocity is decisive. If all steps run at the same pump speed, too much water and chemical are pumped in the steps needing low flow, and the heating load rises too.

If the CIP supply pump motor is driven by a converter and a separate speed is defined for each step, electricity as well as water and chemical consumption fall. HEM Motor's three-phase series are suitable for speed control with a frequency converter. If the motor will remain at low speed and full torque for a long time, an external fan may be needed; if the cable between the panel and the pump is long, a dv/dt or sine filter is considered. It is enough to state these conditions in your order.

In a wet, foamy cleaning environment standard IP55 protection is the basis; at points washed directly with a hose, IP56 can be considered as a special order option.

Prices and technical data are on the product pages; choose a model and order online.

How can consumption at the cooling tower, condenser fan and cold room be reduced?

Tie fan speed to water temperature and close the small losses in the cold room.

The condenser fans and cooling tower fans of an ammonia or freon refrigeration system run at full load in summer and with much less demand in winter. If the fans are only switched on and off by a thermostat, frequent starts both tire the motor and cause fluctuation in water temperature. Linking fan speed to tower outlet water temperature reduces consumption in cooler months, because fan power drops strongly with speed (general information; confirm with the fan manufacturer).

In yoghurt and cheese cold rooms the evaporator fans usually run continuously. The air curtain at the door, the time the door stays open and evaporator icing are small but constant losses that make the compressor and fans run extra. Setting the defrost interval according to actual icing reduces these losses.

Which efficiency class should a motor due for renewal get?

Drives with long running hours should get IE3 or higher. Replacing a motor just because a newer one is more efficient makes sense only on drives that run very long hours. In a dairy, the ice water pump, tower fan and homogeniser are the first candidates in this group. An old motor with a burnt winding or a damaged bearing housing, however, can be replaced with a new model of IE3 or a higher efficiency class instead of being rewound; HEM Motor offers options in IE3, IE4 and IE5 efficiency classes.

At renewal, power should be set from the measured load, not from the nameplate of the existing motor; on a line whose capacity has changed over the years the old motor is often oversized, and at low load both its efficiency and its power factor drop.

For mounting the new motor, foot-mounted B3, flange-mounted B5 and B14, combined B34 and B35 and vertical V1, V3, V5, V6 and V15 options are provided according to frame size, and the flange size is finalised in the order. The IEC frame number is the starting point; compatibility is confirmed by comparing the shaft, foot holes, flange and nameplate values. You can filter candidate models by power and speed among the three-phase electric motors in the shop.

Which electric motors are good examples for a dairy plant?

The models below are given as examples based on powers commonly found in a medium-sized milk processing plant; the exact power should be confirmed with the machine and pump manufacturer's data.

  • For the homogeniser drive, the 37 kW cast iron frame 225S-4; its rated speed is 1485 rpm and its voltage 400/690 V.
  • For a cooling tower or condenser fan, the 11 kW aluminium frame 160M-4; it turns at 1465 rpm.
  • For ice water circulation or a CIP supply pump, the 5.5 kW cast iron frame 132S1-2; its rated speed is 2930 rpm.

For the small drives used on yoghurt cup filling and lidding machines, the packaging machinery electric motors page is also a guide. Cable cross-section and protective devices are determined by the panel engineer on the basis of motor power, line length, starting method and ambient temperature.

How do you plan energy around the seasonal milk curve?

In dairy plants the amount of milk received rises in spring and summer and falls in winter; so the energy plan should also follow the annual milk curve. Before the peak season is the most sensible time to review the ice bank sensors, tower fans and CIP programmes and to identify which motors will be renewed.

You can match the drives on this list by kilowatt and speed on the HEM Motor buying page. For a pump or fan motor whose nameplate has been wiped out by moisture and caustic, reach us through the contact page and share photos of the machine; together we will assess which drive to tackle first, from your ice water circuit to your homogeniser.

Frequently Asked Questions

In a plant with an ice bank, does the compressor also need to run during the day?

If the ice capacity covers the daily cooling demand, the compressor can run mainly at night. In the season when milk reception increases, capacity may not suffice; ice thickness and consumption records should be monitored together.

Does fitting a frequency converter to the homogeniser motor save energy?

On a homogeniser the main energy item is pressure; a converter helps adjust flow but does not lower needlessly high pressure. The pressure recipe per product should be reviewed first, and speed control evaluated together with the machine manufacturer.

Why does the separator motor draw high current for a long time at start-up?

The bowl's inertia is large and reaching full speed takes minutes; during this time the motor draws high current. The motor and its protection should be selected according to the start time given by the separator manufacturer.

Does lowering the CIP pump speed impair cleaning quality?

Not if the minimum flow and velocity required for each step are maintained. Speeds should be defined step by step according to spray ball and pipeline requirements and confirmed with a validation test.

HEM Motor Models Related to This Article

The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.

37 kW 1500 rpm Cast Iron Frame Electric Motor 225S-4

225S-4

37 kW · 1500 rpm

  • Cast iron frame · IEC 225S
  • 1485 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$1,497.78 (€1,370.80)

View product
11 kW 1500 rpm Aluminium Frame Electric Motor 160M-4

160M-4

11 kW · 1500 rpm

  • Aluminium frame · IEC 160M
  • 1465 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$532.46 (€487.32)

View product
5.5 kW 3000 rpm Cast Iron Frame Electric Motor 132S1-2

132S1-2

5.5 kW · 3000 rpm

  • Cast iron frame · IEC 132S
  • 2930 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$332.20 (€304.04)

View product