In dairy plants, the energy cost of electric motors is reduced by first measuring the ice water and cooling circuit and the homogeniser, which account for most of the consumption, then cutting the hours these drives run needlessly, adding speed control to pumps and fans whose flow varies, and replacing motors that are due for renewal with the right power and efficiency class. Every step from milk reception to the filling machine needs cooling, heating and pumping; that is why savings in a dairy come not from one large investment but from smartly adjusting the operating pattern of many drives. Below we take the electric motors of a milk processing plant in process order.
Which drives stand out on a dairy's electricity bill?
On the journey that starts at the raw milk reception tank, milk is first cooled, then heated and cooled again in the pasteuriser, separated from its cream in the separator, passed through the homogeniser and, depending on the product, sent to yoghurt incubation, the cheese vat or the filling machine. After each product the lines are cleaned by CIP. In this flow, the drives that draw the most electricity are usually the ice water compressors and pumps, the homogeniser, the condenser and cooling tower fans, the separator and the CIP pumps.
The power of an electric motor alone does not show the bill; what matters is power multiplied by annual running hours. A 7.5 kW ice water pump turning all night can log more kilowatt-hours than a 30 kW butter churn running two hours a day. So the first task is to rank the motor list not by power but by estimated annual consumption.
| Dairy drive | Typical operating pattern | Energy opportunity |
|---|---|---|
| Ice water compressor and circulation pump | Long hours, also running at night | Ice bank, night tariff, pump speed control |
| Homogeniser | High load throughout production | Pressure by recipe, cutting idle running |
| Separator | Long start, continuous rotation | Avoiding needless rotation between runs |
| CIP supply and return pump | At every product change | Step-based flow, speed control |
| Cooling tower and condenser fan | Varies with season | Fan speed linked to water temperature |
Where is energy wasted in the ice water circuit?
The losses come from a compressor running at daytime peak hours, from excess ice and from a pump circulating for nothing. In dairy plants, ice water at around 1–2 °C is sent to the plate cooler and the tanks. In many dairies this need is met by an ice bank: the compressor runs at night on the cheaper tariff, ice builds up on the coils, and during the day this ice is melted to provide cooling during milk reception and pasteurisation. In plants without an ice bank, the compressor has to run at full load during daytime peak hours.
Correct setting of the ice thickness sensor prevents ice from being built thicker than necessary; excess ice keeps the compressor running for long periods at low suction pressure, in an inefficient zone. The circulation pump also often keeps turning at full speed while consumers are closed. If a frequency converter is fitted to this pump and speed is linked to line pressure, the amount of water pumped for nothing overnight and at weekends falls noticeably; since pump power drops quickly with speed, even a small speed reduction shows on the bill (general information; confirm with the pump manufacturer).
How can the homogeniser's energy use be reduced?
By using the minimum pressure each product needs and cutting idle running. The homogeniser is a high-pressure piston pump and carries one of the largest single electric motors in a dairy. The power it draws is directly related to the product of flow and homogenising pressure. Using the same high pressure for every product, for example applying more pressure than needed for cheese milk or certain yoghurt recipes, means the motor spends extra energy with no product benefit.
Setting the minimum pressure required for each product together with the quality team and writing it into the recipe is a step that needs no investment. The second step is to stop the homogeniser running idle while the pasteuriser is circulating water or while the filling machine is waiting; during these periods the pressure head can be opened or the machine stopped. When the production sequence is arranged so that the homogeniser motor makes planned stops instead of frequent stop-starts, both energy and mechanical life benefit. Writing pressure into the recipe costs nothing.
Which hours are overlooked on separator and pasteuriser pumps?
The idle hours between production runs and while the line circulates water are the ones overlooked. The bowl of a cream separator rotates at high speed and takes minutes to reach full speed. Because of this long start, operators do not want to switch the separator off between runs, and the bowl spins idle for hours.
The start time requires the motor and its protection to be chosen for this heavy start; selection should be based on the start time and inertia data given by the separator manufacturer. If the production plan runs the separator in grouped batches, idle rotation hours become shorter.
The hot water circuit pump and the milk feed pump in the pasteuriser likewise turn at full speed while the line circulates water. Fouling of the regeneration section reduces heat recovery; steam and ice water demand rises, indirectly increasing the load on compressor and pump motors. Regular CIP of the plates and periodic opening and inspection are therefore an electrical matter as well. You can see power ranges for milk and utility fluid pumps on the pump electric motors page.

Why should pump speed be adjusted across CIP steps?
Because each CIP step needs a different flow. In a dairy plant, CIP is a cycle that runs many times a day and each time goes through pre-rinse, caustic, intermediate rinse, acid and final rinse steps. In tank cleaning the spray balls require a certain flow, while in pipe cleaning the flow velocity is decisive. If all steps run at the same pump speed, too much water and chemical are pumped in the steps needing low flow, and the heating load rises too.
If the CIP supply pump motor is driven by a converter and a separate speed is defined for each step, electricity as well as water and chemical consumption fall. HEM Motor's three-phase series are suitable for speed control with a frequency converter. If the motor will remain at low speed and full torque for a long time, an external fan may be needed; if the cable between the panel and the pump is long, a dv/dt or sine filter is considered. It is enough to state these conditions in your order.
In a wet, foamy cleaning environment standard IP55 protection is the basis; at points washed directly with a hose, IP56 can be considered as a special order option.