The Share of Mechanical Transmission Losses in Electric Motor Savings Calculations

The Share of Mechanical Transmission Losses in Electric Motor Savings Calculations

In an electric motor savings calculation, mechanical transmission losses enter the result multiplied by the motor efficiency, and in geared drives they can take a larger share than a change of motor class. If belt, gearbox, coupling and bearing losses are left out, the kilowatt-hour difference expected from switching to an efficient motor comes out higher or lower on paper than it really is.

Why do mechanical transmission losses change the savings calculation?

The power drawn from the grid is found by dividing the power the machine needs for its work by the efficiencies of the motor and the transmission elements. The larger part of the loss often hides not in the motor but in the gearbox placed between motor and machine, or in a slack belt. A maintenance technician standing at a baling press or a belt conveyor looks at the motor nameplate, sees its class and ends the calculation there. Yet part of the power leaving the motor shaft turns into heat in the gears, slip in the belt and friction in the bearings. Renewing the motor while leaving the worm gearbox in place may not show the expected change on the meter.

To build the calculation correctly, the work itself is defined first: the power at the drum shaft, at the pump impeller or at the press ram. The motor is the first element of this chain, not the last.

How are the efficiencies in the chain multiplied?

The efficiencies of elements connected in series are multiplied to give the total efficiency: ηtotal = ηmotor × ηgearbox × ηbelt × ηcoupling. The power drawn from the grid is then Pgrid = Pwork / ηtotal.

The practical consequence of the product rule is this: a single element with low efficiency overshadows improvements in the others. Efficiency values should be taken from the gearbox and belt manufacturers' catalogues according to load and speed; the same gearbox gives a different efficiency at a different ratio (general information; confirm with the machine and transmission element manufacturer).

The motor side needs the same care. Part-load efficiency is not the same as rated efficiency and must be read at the motor's real operating point. The shop page can be used to compare power and speed steps.

Hypothetical example: does the gearbox or the motor class weigh more?

All values below are hypothetical; they were chosen to show the method and do not belong to any specific product. The work power needed at the conveyor drum is taken as 6 kW.

ScenarioMotor efficiencyGearbox efficiencyTotal efficiencyPower drawn from grid
Present state: worm gearbox0.900.700.6306 / 0.630 ≈ 9.52 kW
Only the motor changed0.930.700.6516 / 0.651 ≈ 9.22 kW
Only the gearbox became helical0.900.950.8556 / 0.855 ≈ 7.02 kW
Both changed0.930.950.8846 / 0.884 ≈ 6.79 kW

In this hypothetical table, changing the motor alone brings a difference of about 0.30 kW per hour, while changing the gearbox brings about 2.50 kW. The annual energy difference is found by multiplying these values by the running hours; its monetary value is the kWh difference × the site's own unit price.

The result is not the same for every drive.

In a pump drive with a helical gearbox and a properly tensioned belt, the transmission loss is already small and the motor class takes a more visible share. What matters is building the calculation for the drive in question.

Your own machine's figures, not a generic table.

How is loss in belts, couplings and bearings recognised on site?

Transmission loss shows up as heat; when the gearbox housing, belt surface and bearing covers are measured with a non-contact thermometer, the element running too hot gives itself away. The measurement is taken after the machine reaches thermal balance and from the same point each time.

A slack V-belt can be heard squealing at start-up, and glazing on the pulley flanks and dust along the belt edges can be seen. Slip can also be found numerically by measuring motor speed and driven shaft speed with a tachometer and comparing them with the pulley ratio. An over-tensioned belt prevents slip but puts unnecessary radial load on the motor bearing and shaft end.

Shaft misalignment at the coupling is recognised by dust from the rubber element and heating around the coupling. Misalignment increases friction both in the coupling and in the bearings on either side. A dial indicator or a laser device is used to measure alignment.

Oil counts too. A wrong oil level or viscosity in the gearbox increases loss. Too much oil causes churning loss, too little causes friction on the tooth flanks; both appear in the housing temperature.

Electric motor connected to a parallel shaft gearbox
The type and ratio of the gearbox affect the total efficiency of the drive chain as much as the motor does (representative image).

Prices and technical data are on the product pages; choose a model and order online.

How is transmission loss separated by measurement?

The most reliable way is to measure the power the motor draws from the grid with a three-phase power analyser and, at the same time, derive the power on the work side from process data. The difference between the two is the sum of motor and transmission losses.

Motor loss is separated approximately using the part-load efficiency in the catalogue. The remainder belongs to the transmission elements. If the measurement is repeated before and after adjusting belt tension, the effect of that single intervention also becomes visible.

In drives fed by a frequency inverter, the drive's own loss enters the calculation separately. Our three-phase series are suitable for speed control with a frequency inverter; long operation at low speed with full torque may require a separate fan; if the drive-to-motor cable is long, a dv/dt or sine filter is considered; these conditions are stated with the order.

Which mistakes are made in savings calculations?

The most common mistake is taking the motor's nameplate power as the work power. Nameplate power is the limit the motor can deliver; the machine's real need usually stays lower, and the calculation inflates.

The second mistake is forgetting the transmission ratio when the motor changes. If the new motor's speed differs by a few rpm and the pulley ratio stays the same, the machine turns slightly faster, does extra work and takes extra power from the grid. The change on the meter therefore looks smaller than expected.

The third is assuming gearbox efficiency is a single value. The efficiency of worm gearboxes changes noticeably as the ratio rises and during the running-in period after first start-up; the relevant catalogue line must be read.

How are the motor and the transmission selected together?

Selection works backwards from work power and work speed: first the machine's need, then the transmission type and ratio, and last the motor power and speed are determined. This keeps the motor from being far too large or right at the limit.

Three steps from the 4-pole aluminium frame series often used in geared conveyor and press drives: 132S-4 (5.5 kW; rated torque 36 Nm; rated current 10.7 A at 400 V), 132M-4 (7.5 kW; 49.1 Nm; 14.3 A) and 160M-4 (11 kW; 71.7 Nm; 20.4 A). These models are 400/690 V, IP55 with class F insulation. HEM Motor offers IE3, IE4 and IE5 classes; the class per model is confirmed with the order. For the class pages see the IE3 and IE4 groups.

All frames of the family can be found on the asynchronous electric motors page. For fitting to a gearbox flange, mounting arrangements such as B5 and B14 are offered according to frame; the flange size is confirmed with the order.

If you send your drive's motor nameplate, gearbox or pulley details and the grid power you measured through our contact page, we will work out the share of each link in the chain together and look at where the change should start. Current prices can be seen in the HEM Motor product list.

Frequently Asked Questions

Where can gearbox efficiency be found?

It is given in the gearbox manufacturer's catalogue by type, ratio and speed. If the catalogue cannot be found, the type and ratio are read from the gearbox nameplate and the manufacturer is asked.

Does adjusting belt tension affect energy consumption?

A slipping belt turns energy into heat and lowers the speed of the driven shaft; correct tension reduces this loss. Excessive tension increases bearing friction, so the value recommended by the manufacturer is used.

Should the gearbox also change when switching to an efficient motor?

It is not mandatory, but if the gearbox is the least efficient element in the chain, assessing it first may make more sense. The decision is made by calculating the kWh difference of each option separately.

Does transmission loss also heat the motor?

Because transmission loss raises the power the machine demands, the motor runs more heavily loaded and gets hotter. In addition, coupling misalignment or excessive belt tension loads the motor bearing directly.

HEM Motor Models Related to This Article

The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.

5.5 kW 1500 rpm Aluminium Frame Electric Motor 132S-4

132S-4

5.5 kW · 1500 rpm

  • Aluminium frame · IEC 132S
  • 1460 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$320.18 (€293.04)

View product
7.5 kW 1500 rpm Aluminium Frame Electric Motor 132M-4

132M-4

7.5 kW · 1500 rpm

  • Aluminium frame · IEC 132M
  • 1460 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order