In electric motor modernisation, motor, pump and pipeline are assessed as a single system: first the flow and head the line really needs are determined, then where the pump works on its curve is measured, and the motor is chosen last. Replacing only the motor with a higher efficiency class while a throttled valve or an oversized pump remains leaves the largest part of the loss where it is.
Why is replacing only the motor not enough?
In a pump system the energy drawn from the grid passes in turn through motor, coupling, pump, valve and pipe to the fluid. A loss occurs at every link, and these multiply together. The motor is usually the most efficient link in the chain.
A common picture on site is this: safety margin has been added on top of safety margin in the design, the pump has been oversized, and the excess pressure has been destroyed by half-closing the outlet valve. The pressure spent across the valve is power the motor produces but that does no useful work. Upgrading the motor class touches only a small share of this loss.
A simple observation often gives a clue. If the valve handle has stood in the same half-closed position for years, if there is a large difference between the gauge at the pump outlet and the pressure at the end of the line, or if a whistling flow noise comes from inside the valve, the system's need and the pump's capacity do not match.
How is the system's real need measured on site?
Three quantities are recorded together: flow, head and the motor's active power. For flow, a clamp-on ultrasonic flowmeter can be used without cutting the pipe; pressure is read from gauges at the pump suction and discharge; active power is measured at the motor input with an energy analyser.
Measurements should not be limited to a single moment. To see how flow changes over a typical day at the plant, recording lasts at least one shift. On an irrigation or process water line the difference between morning and afternoon can be large enough to change the motor selection. Measuring points matter too. A gauge fitted right behind an elbow gives a fluctuating reading; for the ultrasonic sensor, the straight pipe length recommended by the manufacturer must be provided (general information; confirm with the measuring instrument manufacturer's instructions).
How is wire-to-water efficiency calculated?
To see the whole system as a single number, wire-to-water efficiency is used: the ratio of the hydraulic power delivered to the fluid to the active power the motor draws from the grid. For water, hydraulic power is found in practice with Ph (kW) = Q (m³/h) × H (m) / 367.
Hypothetical example: a line runs at a flow of 60 m³/h and the total head measured at the pump outlet is 40 m. Hydraulic power = 60 × 40 / 367 ≈ 6.54 kW. The analyser shows 11.6 kW at the motor input. Wire-to-water efficiency ≈ 6.54 / 11.6 ≈ 0.56.
The real question is how much of the 40 m is actually needed. When the requirement at the end of the line and pipe friction are calculated, 28 m turns out to be enough; the remaining 12 m is spent in the valve. For the required head alone, hydraulic power is 60 × 28 / 367 ≈ 4.58 kW. The roughly 2 kW of hydraulic power in between, divided by motor and pump efficiency, corresponds to an even larger share of the power drawn from the grid.
When you multiply this difference by annual running hours and assess it with your plant's unit energy price, it becomes clear which intervention has priority. The values in the example are hypothetical; put in your own measurements.
In modernisation, motor, pump and line are assessed from the same measurement record (representative image).
Prices and technical data are on the product pages; choose a model and order online.
In what order should the interventions be tackled?
The order matters, because each step changes the size of the next. First the need is reduced, then the pump is matched to the need, and the motor is chosen last. Working in reverse means paying for a motor that will be too large after the next step.
Step
Intervention
Effect on motor selection
1. Line
Unnecessary valve throttling, clogged filter, narrow or scaled pipe, unnecessary bypass are reviewed
Required head falls
2. Pump
Impeller trimming, a smaller impeller or a new pump suited to the duty point
Shaft power demand shrinks
3. Control
Speed control with a frequency converter for variable flow
Motor suitability for the drive and its cooling are checked
4. Motor
Selection of power and efficiency class for the new shaft power
Last step; sized on the results of the others
On variable-flow lines speed control is especially effective. According to the affinity laws for centrifugal pumps, flow changes with speed, head with the square of speed and power roughly with the cube of speed (general information; this relationship weakens in systems with high static head, confirm with the pump manufacturer). That is why reducing speed instead of throttling with a valve often makes the biggest difference.
Which mistakes are made most often in modernisation?
The first is copying the old motor's nameplate power directly for the new motor.
If the old motor was already oversized, the same mistake is repeated once more. The second is downsizing the pump and leaving the motor as it is. The motor then runs at light load and power factor drops. If the pump has changed, the motor's load ratio must be checked again too. The third is not thinking about minimum speed when moving to speed control. Below a speed at which the pump cannot overcome the static head, flow approaches zero while the motor keeps turning. That is why the minimum frequency limit in the drive is set by trial on site.
The fourth is coupling alignment. If the new motor and pump are fitted to the same base and commissioned without checking alignment with a dial gauge or laser alignment tool, bearings and the gland are strained within a short time.
Which example motors suit this system?
Three 2-pole models that can be considered for the line in the hypothetical example, after the valve loss has been removed and the pump resized, are listed below. All have IP55 protection, class F insulation and are suitable for use with a frequency converter. The full power and speed table can be seen in the HEM Motor shop.
132S2-2: 7.5 kW, 2930 rpm, 13.7 A at 400 V, rated torque 24.4 Nm. For systems whose shaft power falls clearly after the line is improved.
160M1-2: 11 kW, 2945 rpm, 19.6 A at 400 V, rated torque 35.7 Nm. For those who, as in the example, want to keep the existing power and change only pump and control.
160L-2: 18.5 kW, 2940 rpm, 32.5 A at 400 V, rated torque 60.1 Nm. Cast iron frame; for humid pump rooms and larger lines.
You can see the efficiency class options on the IE4 high efficiency series page; which class is available for each model is confirmed with the order. The family's general table is on the asynchronous electric motors page.
If you send your flow, pressure and power recording together with a photo of the existing motor's nameplate via our contact page, we can calculate together the motor power needed once the valve loss is removed. Current model information is available on our sales page.
Frequently Asked Questions
How can I estimate pump efficiency on site?
Calculate hydraulic power from the measured flow and head, and find shaft power using motor input power and the catalogue motor efficiency. The ratio of hydraulic power to shaft power gives pump efficiency.
Should the motor also be downsized when the impeller is trimmed?
Not necessarily, but it should be checked. If shaft power has fallen clearly, the motor stays at light load; the decision is made by measuring load ratio and power factor.
Does a frequency converter make a difference on every pump?
No. On lines with constant flow and dominant static head, the contribution of speed control is limited. On variable-flow lines it is usually far more effective than throttling with a valve.
Should pipeline changes be made before ordering the motor?
If possible, yes. A new measurement taken after the line is improved ensures the motor power is selected correctly.
HEM Motor Models Related to This Article
The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.
In an energy audit for an electric motor, the measuring points should be set as the panel outgoing feeder that supplies the motor, the motor terminal box and, where possible, the s... More Details
Yes. The power drawn by the cooling fan mounted on the motor's own shaft is included in the total losses under "friction and windage loss" when efficiency is measured; the catalogu... More Details
A copper rotor has lower electrical resistance than an aluminium rotor, so it reduces rotor losses and can deliver higher efficiency in the same frame; but the efficiency class can... More Details
The test method in an efficiency report should be asked about because the same electric motor can give different efficiency values when measured by different methods, and when two ... More Details
In an electric motor replacement project, the reduction in carbon emissions is calculated by taking the difference in energy that the old and new motors draw from the supply for th... More Details
Excess power margin keeps the electric motor running permanently at part load: the motor does not fail, but at low load its efficiency slips a little, its power factor drops notice... More Details