When choosing a motor for a peristaltic pump, the deciding value is not flow or pressure but the torque the rotor needs to squeeze the hose. The rotor turns slowly, so a gearbox almost always sits in between; the required motor torque is found with Tmotor = Trotor / (i × ηgearbox), and this load has a constant torque character that does not fall as speed drops.
Where does torque come from in a peristaltic pump?
Most of the torque comes from squeezing the hose. The rollers or shoes on the rotor press the hose against the housing track and close it completely; this is called occlusion. Bending the hose wall on every turn, pushing the trapped volume to the outlet and overcoming the spring-back of the compressed elastomer all take work.
Discharge pressure also takes a share, but in most dosing and transfer duties it comes second to the squeezing work. The third item is friction: roller bearings in roller pumps, the shoe sliding over the hose in shoe pumps. Shoe-type housings are filled with lubricant, and the friction share is clearly larger than in roller types.
This picture has an important consequence for the motor. In a centrifugal pump torque falls with the square of speed; here it does not. At half speed the rotor still squeezes the hose with the same force.
What makes hose squeezing torque larger?
Five factors make the biggest difference on site.
- Hose material and wall thickness. A hard, thick-walled hose needs more squeezing work than a soft one.
- Occlusion setting. If too many shims go under the shoe or roller, the hose is squeezed more than needed; torque rises and hose life shortens.
- Temperature. Cold elastomer is stiff. At the first start on a winter morning the current reads noticeably high.
- Sticking after standstill. During a long stop the squeezed section takes a set and sticks to the track; breakaway torque rises above running torque.
- The fluid itself. Dense sludge, lime milk or solids-laden liquid raise both pressure and friction.
As the hose wears, the wall gets thinner and torque drops somewhat; when a new hose is fitted, it rises during the first hours. The first start after a change is therefore a checkpoint.
How do you get from rotor speed to motor torque?
First the power needed at the rotor is found, then it is carried to the motor shaft through the gearbox ratio and efficiency. The sequence is:
- Rotor torque Trotor and maximum rotor speed nrotor are taken from the pump manufacturer's data.
- Rotor power: Protor = Trotor × nrotor / 9550 (kW, Nm, rpm).
- The ratio is motor speed divided by rotor speed: i ≈ nmotor ÷ nrotor.
- Motor torque: Tmotor = Trotor / (i × ηgearbox).
- This value is compared with the motor's nominal torque; for breakaway, the motor's starting torque ratio is checked separately in the catalogue.
Let us set up a hypothetical example. The rotor will turn at most 40 rpm, the pump manufacturer gives a rotor torque of 400 Nm, and the helical gearbox efficiency is 0.90.
| Item (hypothetical) | 4-pole option | 6-pole option |
|---|---|---|
| Motor speed | 1450 rpm | 955 rpm |
| Gearbox ratio | 1450 / 40 ≈ 36 | 955 / 40 ≈ 24 |
| Required motor torque | 400 / (36 × 0.90) ≈ 12.3 Nm | 400 / (24 × 0.90) ≈ 18.5 Nm |
| Example model | 2.2 kW 100L1-4 (14.5 Nm) | 2.2 kW 112M-6 (22 Nm) |
| Torque loading | ≈ 85% | ≈ 84% |
Rotor power comes to 400 × 40 / 9550 ≈ 1.68 kW. With gearbox losses, about 1.87 kW is needed at the motor shaft. The 2.2 kW step is enough. But once cold starts and a stiff hose are taken into account, the 3 kW class is a more comfortable margin. The figures are hypothetical; take the rotor torque from your own pump's data (general information; confirm with the pump manufacturer's instructions).

How does lowering speed for flow control affect the motor?
In a peristaltic pump, flow is directly proportional to rotor speed: Q = Vrev × nrotor. That is why dosing accuracy is mostly achieved by adjusting speed with a frequency inverter.
Here is the catch. Because the load is constant torque, the motor still draws close to rated current at low frequency, but the shaft-mounted fan slows down and cooling air drops. When the rotor in the example is turned down to 10 rpm, the motor runs at roughly 12–13 Hz and still delivers about 12 Nm. On a dosing line that stays at that speed for hours, the motor frame heats up.
Our three-phase series are suitable for speed control with a frequency inverter; for long periods at low speed with full torque a separately driven fan may be needed; if the drive-to-motor cable is long, a dv/dt or sine filter is considered; these conditions are stated with the order.
An alternative is to choose the gearbox ratio to suit the flow range. If the most frequently used flow keeps the motor in the 35–50 Hz band, the cooling problem largely disappears. If a very wide adjustment range is needed, fitting a PTC in the winding ties heating to measurement rather than guesswork.