Electric Motor for a Peristaltic Pump: Hose Squeezing Torque and Speed

Electric Motor for a Peristaltic Pump: Hose Squeezing Torque and Speed

When choosing a motor for a peristaltic pump, the deciding value is not flow or pressure but the torque the rotor needs to squeeze the hose. The rotor turns slowly, so a gearbox almost always sits in between; the required motor torque is found with Tmotor = Trotor / (i × ηgearbox), and this load has a constant torque character that does not fall as speed drops.

Where does torque come from in a peristaltic pump?

Most of the torque comes from squeezing the hose. The rollers or shoes on the rotor press the hose against the housing track and close it completely; this is called occlusion. Bending the hose wall on every turn, pushing the trapped volume to the outlet and overcoming the spring-back of the compressed elastomer all take work.

Discharge pressure also takes a share, but in most dosing and transfer duties it comes second to the squeezing work. The third item is friction: roller bearings in roller pumps, the shoe sliding over the hose in shoe pumps. Shoe-type housings are filled with lubricant, and the friction share is clearly larger than in roller types.

This picture has an important consequence for the motor. In a centrifugal pump torque falls with the square of speed; here it does not. At half speed the rotor still squeezes the hose with the same force.

What makes hose squeezing torque larger?

Five factors make the biggest difference on site.

  • Hose material and wall thickness. A hard, thick-walled hose needs more squeezing work than a soft one.
  • Occlusion setting. If too many shims go under the shoe or roller, the hose is squeezed more than needed; torque rises and hose life shortens.
  • Temperature. Cold elastomer is stiff. At the first start on a winter morning the current reads noticeably high.
  • Sticking after standstill. During a long stop the squeezed section takes a set and sticks to the track; breakaway torque rises above running torque.
  • The fluid itself. Dense sludge, lime milk or solids-laden liquid raise both pressure and friction.

As the hose wears, the wall gets thinner and torque drops somewhat; when a new hose is fitted, it rises during the first hours. The first start after a change is therefore a checkpoint.

How do you get from rotor speed to motor torque?

First the power needed at the rotor is found, then it is carried to the motor shaft through the gearbox ratio and efficiency. The sequence is:

  1. Rotor torque Trotor and maximum rotor speed nrotor are taken from the pump manufacturer's data.
  2. Rotor power: Protor = Trotor × nrotor / 9550 (kW, Nm, rpm).
  3. The ratio is motor speed divided by rotor speed: i ≈ nmotor ÷ nrotor.
  4. Motor torque: Tmotor = Trotor / (i × ηgearbox).
  5. This value is compared with the motor's nominal torque; for breakaway, the motor's starting torque ratio is checked separately in the catalogue.

Let us set up a hypothetical example. The rotor will turn at most 40 rpm, the pump manufacturer gives a rotor torque of 400 Nm, and the helical gearbox efficiency is 0.90.

Item (hypothetical)4-pole option6-pole option
Motor speed1450 rpm955 rpm
Gearbox ratio1450 / 40 ≈ 36955 / 40 ≈ 24
Required motor torque400 / (36 × 0.90) ≈ 12.3 Nm400 / (24 × 0.90) ≈ 18.5 Nm
Example model2.2 kW 100L1-4 (14.5 Nm)2.2 kW 112M-6 (22 Nm)
Torque loading≈ 85%≈ 84%

Rotor power comes to 400 × 40 / 9550 ≈ 1.68 kW. With gearbox losses, about 1.87 kW is needed at the motor shaft. The 2.2 kW step is enough. But once cold starts and a stiff hose are taken into account, the 3 kW class is a more comfortable margin. The figures are hypothetical; take the rotor torque from your own pump's data (general information; confirm with the pump manufacturer's instructions).

Electric motor driving a chemical process pump
In dosing and process pumps, motor torque is calculated from the rotor's need through the gearbox ratio and efficiency (representative image).

How does lowering speed for flow control affect the motor?

In a peristaltic pump, flow is directly proportional to rotor speed: Q = Vrev × nrotor. That is why dosing accuracy is mostly achieved by adjusting speed with a frequency inverter.

Here is the catch. Because the load is constant torque, the motor still draws close to rated current at low frequency, but the shaft-mounted fan slows down and cooling air drops. When the rotor in the example is turned down to 10 rpm, the motor runs at roughly 12–13 Hz and still delivers about 12 Nm. On a dosing line that stays at that speed for hours, the motor frame heats up.

Our three-phase series are suitable for speed control with a frequency inverter; for long periods at low speed with full torque a separately driven fan may be needed; if the drive-to-motor cable is long, a dv/dt or sine filter is considered; these conditions are stated with the order.

An alternative is to choose the gearbox ratio to suit the flow range. If the most frequently used flow keeps the motor in the 35–50 Hz band, the cooling problem largely disappears. If a very wide adjustment range is needed, fitting a PTC in the winding ties heating to measurement rather than guesswork.

Prices and technical data are on the product pages; choose a model and order online.

How does pulsating load strain the motor and gearbox?

As each roller enters and leaves the hose, torque rises and falls. On pumps with few rollers this ripple is pronounced; shaft, coupling and gear teeth see the same load swing on every turn.

Couplings with elastic elements soften these shocks. On the gearbox side, the margin the manufacturer recommends for the shock load class is added by checking the catalogue. On the motor side, the real point to watch is how close the peak current, not the average, comes to the nameplate value. A clamp meter usually shows the average; a logging instrument is needed for the peak.

The rhythm of the noise is also a sign. A regular knock matching the roller passes is normal; an irregular knock can point to a loose coupling or a worn gear tooth.

Which site measurements confirm the motor choice?

Current and frame temperature should be logged at the two most used speeds and under two different conditions.

  • First start current with a new hose in a cold environment.
  • Running current with the hose at working temperature.
  • Frame temperature after an hour at the lowest set speed.
  • The change in current after the occlusion setting is altered.

If current climbs over the months under the same conditions, a degraded shoe lubricant, a strained roller bearing or drifting occlusion is suspected. The records also help plan the hose change interval.

Which HEM Motor models fit this calculation?

For the need in the example, the cast iron 100L1-4 (2.2 kW, 1450 rpm, 14.5 Nm) fits, the 100L2-4 (3 kW, 1450 rpm, 19.8 Nm) gives a wider margin, and the 112M-6 (2.2 kW, 955 rpm, 22 Nm) suits lines working with a lower-ratio gearbox. All three carry a 230/400 V rating. Other options by power and speed are listed in the electric motor shop.

Pump drives are collected on the pump electric motors page; motors to be coupled to a gearbox are on the electric motors for gearboxes page. Standard frames come with IP55 protection and class F insulation; PTC/PT100 winding sensors and anti-condensation heaters are order options.

Send your pump's rotor torque and speed range, the gearbox nameplate and the hose type you use through our contact page; we will look at the constant torque and low speed condition together and suggest the motor accordingly. You can compare the chosen model by speed and torque in the HEM Motor product list.

Frequently Asked Questions

Is the motor power of a peristaltic pump chosen by flow?

No; flow sets the rotor speed, while motor power is set by rotor torque and maximum speed. Two pumps giving the same flow can need very different torque depending on the hose type.

Does a shoe pump need a different motor than a roller pump?

Often yes. In shoe pumps the shoe slides along the hose; this extra friction raises torque compared with a roller pump of the same size. The rotor torque value should be taken from the manufacturer for the pump type.

What if the motor will not start after a long standstill?

The hose may have stuck to the track at the squeezed section. Occlusion setting and hose condition are checked; if it recurs, a motor with a higher starting torque ratio is chosen or the calculation is repeated with a pessimistic gearbox efficiency.

Can flow be adjusted without an inverter?

If a fixed flow is enough, a single speed is chosen through the gearbox ratio. If flow changes often, an inverter is the practical solution; the cooling condition at low speed should be stated with the order.

HEM Motor Models Related to This Article

The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.

2.2 kW 1500 rpm Cast Iron Frame Electric Motor 100L1-4

100L1-4

2.2 kW · 1500 rpm

  • Cast iron frame · IEC 100L
  • 1450 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$184.70 (€169.04)

View product
3 kW 1500 rpm Cast Iron Frame Electric Motor 100L2-4

100L2-4

3 kW · 1500 rpm

  • Cast iron frame · IEC 100L
  • 1450 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$199.92 (€182.97)

View product
2.2 kW 1000 rpm Cast Iron Frame Electric Motor 112M-6

112M-6

2.2 kW · 1000 rpm

  • Cast iron frame · IEC 112M
  • 955 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$232.73 (€213.00)

View product

Similar Articles