When choosing an electric motor for a dosing pump, the adjustment range is the flow band produced jointly by the stroke length setting and the motor speed. Mounting dimensions are verified from the technical drawing against the flange of the pump gearbox; first the speed at the smallest and largest flow, then the flange type and shaft data must be settled.
Which two settings change flow on a dosing pump?
On piston and diaphragm dosing pumps, two things decide flow: the volume pushed per stroke and the number of strokes per minute. The first is changed with the adjusting knob on the pump body or with a servo actuator. The second depends on the motor's rotating speed and the gearbox ratio.
Whether chlorine and coagulant in water treatment, oxygen scavenger in boiler houses, or CIP acid and caustic in dairy and beverage plants are being dosed, the logic is always the same.
Making the stroke very short spoils accuracy.
With short strokes, valve leakage and air bubbles in the suction line grow proportionally within the dose delivered. Most pump manufacturers recommend a lower limit for the stroke setting (general information; confirm with the pump manufacturer's catalogue). If a wide adjustment band is needed, speed carries the load.
How does motor speed widen the adjustment range?
When the motor is slowed with a drive, the number of strokes per minute falls in the same proportion. Stroke length is held at a reasonable point and flow goes down or up with speed.
Treatment lines where raw water volume changes during the day like this method. The flowmeter's 4–20 mA signal is wired to the drive, and the drive speeds the pump motor up or down to match the incoming water.
Two things are watched at slow speed. Cooling comes first, because the motor's own impeller slows down too, and if full torque is wanted at low speed for hours a separately powered fan is considered. Torque ripple comes second: on a piston pump every delivery stroke sends a pulse to the shaft, and at low speed that pulse shows itself more clearly in the coupling and gearbox.
HEM Motor's three-phase series are suitable for speed control with a drive. If the cable between drive and motor is long, a dv/dt or sine filter is discussed and this is written on the order form.
On pumps that will turn at fixed speed without a drive, adjustment is made only with the stroke knob. Motor selection then comes down to power, speed and flange.
Which power and speed steps are seen on dosing pumps?
Most dosing pumps are low-power. Steps from fractional kilowatts up to a few kilowatts are common, and which one is needed depends on the pump's discharge pressure, flow and gearbox efficiency.
The power value is read from the pump manufacturer's table. As discharge pressure and flow rise, the required shaft power increases, and the loss of the worm gearbox is added on top. All the low-power steps are listed in order of power in the HEM Motor store.
In speed, 4 poles dominate. Combined with a worm gearbox the required stroke frequency is reached with a reasonable ratio; on large, slow-stroking piston pumps a six-pole option may also come to mind.
If the old motor's plate is illegible on site, the number of strokes the pump makes per minute is counted with a stopwatch. Multiplying that number by the gearbox ratio gives the motor speed and removes the risk of getting the pole number wrong.
A picture often seen in treatment plants: the motor of a pump that has run for years has burned out, its plate is under paint, but the gearbox label is still readable. If the gearbox ratio is known and the pump catalogue states the maximum stroke frequency, motor speed is worked back from these two figures; the nearest 4- or 6-pole step to that speed is then chosen. If the pump manufacturer's catalogue is not at hand, a stroke count taken with a stopwatch from the standby pump or the same model on a sister line also does the job. This small calculation prevents an ordered motor arriving at the wrong speed and halving or doubling the dose.