An IE5 electric motor fits an existing base frame only after the IEC frame number, mounting type, foot hole spacing, shaft and flange data have been compared with the old motor; a matching frame number on its own is not enough. Higher-efficiency motors can come with a longer housing at the same power or with a different terminal box position, so the measuring work is done before the order is placed.
A maintenance team replacing an old motor with a more efficient electric motor first takes the right dimensions at the base frame. It then checks the flanged connection and picks a reasonable correction when a difference turns up.
Can a more efficient electric motor bolt onto the old motor's base without changing the bolts?
In most cases yes, but saying so without measuring would be wrong. In the IEC system the transverse and longitudinal distance between the foot holes and the height of the shaft axis depend on the frame number, so the foot holes of two motors carrying the same frame number should land on the same grid.
The mismatch usually comes from somewhere else. The overall length of the motor, the space taken by the fan cover at the rear, whether the terminal box sits on top or on the side, the direction of the cable entry and the distance from the shaft shoulder on the coupling side to the front foot hole decide whether the motor fits the base. On a belt drive the length of the tensioning rail matters, and on a coupled drive so does the gap between the two shaft ends.
What do the number and letter in the frame code tell you about the base frame?
The number in the frame code gives the height of the shaft axis above the foot base, and the letter gives the class of the longitudinal foot hole spacing. S means short, M medium and L long; M and L frames with the same number stand at the same height but have different longitudinal holes.
HEM Motor's cast iron series shows a concrete example: the 11 kW motor coded 160M-4 and the 15 kW motor coded 160L-4 have the same shaft height, yet one comes with M hole spacing and the other with L. The holes no longer line up. A team raising power from 11 kW to 15 kW may have to drill new holes in the base or fit an adapter plate. The general match between frame and power is shown in the frame size table; for numerical dimensions the HEM Motor technical drawings are the reference.
We have collected the general features of motors in this class on our IE5 Ultra Premium Efficiency Electric Motors page; the efficiency class in which a listed model is supplied is confirmed with the order.
Which dimensions should be taken from the existing motor, and in what order?
First the nameplate, then the feet, and last the shaft and flange; this order reduces wrong comparisons. Before removing the motor, record the following steps on a measurement sheet:
- Take a sharp photo of the nameplate: power, speed, voltage, connection and frame code should be legible. If the plate is worn off, look for the embossed lettering on the cast housing.
- Measure the centre-to-centre transverse and longitudinal spacing of the foot holes with a caliper or steel rule rather than a tape measure. Note the hole diameter and the bolt length in the base.
- Measure the height from the base surface to the shaft centre; if there is a shim pack in between, write down its thickness separately.
- Measure the shaft diameter, shaft length and key width. If the coupling hub will not come off the shaft, use the bore data from the coupling manufacturer.
- Take the distance from the shaft shoulder to the nearest foot hole. This is the value that sets the coupling gap.
- On a flanged motor, record the spigot diameter, the pitch circle, the number of holes and whether the holes are clearance or tapped.
- Photograph the free space behind the fan cover and the clearance around the terminal box.
Once the dimensions are taken, compare them line by line with the technical drawing of the new motor. The IEC frame number is the first piece of compatibility information; full compatibility is confirmed by comparing mounting type, shaft diameter and length, foot hole spacing, flange and electrical ratings.

What does the difference between a B5 and a B14 flange change when fitting the new motor?
On a B5 flange the bolt passes through from behind the flange and is tightened with a nut on the other side; on a B14 face flange the bolt screws straight into the thread in the motor flange. That is why a B14 motor cannot be mounted on a B5 gearbox, or the other way round, without an intermediate part.
Even when the type stays the same, the flange definition has to match exactly. Some frames are offered with more than one flange size, so writing only "B14" is not enough information; the spigot diameter and pitch circle should be stated clearly in the order. In pump and gearbox applications the cleanliness of the spigot face also decides misalignment. Old gasket residue or paint can push the motor off axis. B3, B5, B14, B34, B35 and vertical V1/V3/V5/V6/V15 are offered according to frame; flange size is confirmed with the order.