At part load, an electric motor built to the IE5 level holds its efficiency and power factor across a wider load range than an IE3 induction motor. In the IE3 motor, once load falls below half, fixed losses take a larger share and the efficiency curve bends noticeably downward. The gap is small at rated load and widest at quarter load. That is why the comparison should be made against the plant's real load profile, not the class on the nameplate.
Why does an IE3 induction motor lose efficiency as load drops?
An IE3 induction motor loses efficiency as load drops because fixed losses take a growing share of the total. Splitting the motor's losses into two groups makes this easier to follow: losses that do not depend on load, and losses that grow with it.
The load-independent group contains iron (core) losses, bearing friction and the power the fan spends pushing air. While the motor is energised and turning, these stay almost the same even if the shaft is running idle. The load-dependent group contains copper losses in the stator and rotor windings plus additional (stray) losses. These rise with the square of the current.
As general engineering knowledge, an induction motor's efficiency peaks where variable losses approach fixed losses. In most motors this point sits somewhat below rated load. When load falls to a quarter, copper losses shrink. Iron and friction losses stay put. Shaft power, however, has dropped to one quarter. The efficiency formula shows it plainly:
η = Pshaft / (Pshaft + Pfixed + Pvariable)
When the numerator shrinks and the fixed term in the denominator stays the same, the ratio falls quickly (general knowledge; confirm the motor's part-load data in the manufacturer's data sheet).
Why does an IE5-level electric motor draw a flatter curve at low load?
Designs that reach the IE5 level also cut fixed losses, so the curve bends less at low load. This level is usually reached in one of two ways. The first is a lower-loss build with better lamination steel, more active material and an improved fan. The second is a synchronous design whose rotor uses permanent magnets or a reluctance structure instead of conducting bars.
In synchronous designs there is no rotor current, so rotor copper loss disappears and magnetisation is not supplied by current drawn from the grid. The result is efficiency that stays closer to its rated value at half load and below. On the other hand, such motors usually run on a frequency drive. The drive's own losses are added to the calculation too.
HEM Motor offers motors in the IE3, IE4 and IE5 efficiency classes. For a given power and frame, which class, which rotor design and whether a drive is required must be confirmed when ordering. Do not finalise the comparison before that information arrives.
We have collected the general features of motors in this class on our IE5 Ultra Premium Efficiency Electric Motors page; the efficiency class in which a listed model is supplied is confirmed with the order.
How does power factor change in the two motors at half load?
At half load, the power factor of an IE3 induction motor drops clearly, while in a magnet-based synchronous design the drop is much more limited. An induction motor builds its magnetic field with reactive current drawn from the grid. Even as load falls, this current hardly changes. As the working current shrinks, the reactive share grows and cosφ falls.
You can see this on site with a clamp meter: an induction motor running close to no load keeps drawing a considerable part of its rated current. A low cosφ does not directly change the motor's own efficiency. Even so, extra current is carried on the cable and transformer side, and the compensation panel works harder. In a drive-fed motor the grid-side power factor is set by the drive's input stage; the cosφ on the motor nameplate does not appear there directly.
Prices and technical data are on the product pages; choose a model and order online.
How is the loss difference between the two motors calculated from the load profile?
The loss difference is calculated by multiplying the difference in loss power between the two motors in each load band by the hours spent in that band, then adding the results. Multiplying a single efficiency figure by annual hours gives the wrong answer on lines that run at part load.
Log the line with a power analyser for at least several days, preferably covering different shifts and seasons.
Divide the records into load bands (for example a quarter, half, three quarters and all of rated power) and work out the annual hours spent in each band.
Ask the manufacturer for the loss power (or part-load efficiency) of both motors at the same load points. For the drive-fed option, add the drive loss as well.
For each band calculate difference = (Ploss,IE3 − Ploss,IE5) × hours, and add them up.
The table below is a purely hypothetical example built only to show the method; the values do not belong to any HEM Motor model.
Load band
Annual hours (hypothetical)
IE3 loss (hypothetical)
IE5 loss (hypothetical)
Loss difference × hours
Full load
1200 h
1.4 kW
1.0 kW
480 kWh
Three-quarter load
2000 h
1.1 kW
0.8 kW
600 kWh
Half load
3000 h
0.9 kW
0.6 kW
900 kWh
Quarter load
1500 h
0.8 kW
0.45 kW
525 kWh
In this scenario the total difference comes to 2505 kWh, and most of it comes from the half-load and quarter-load hours. Had you done the same calculation with the full-load loss only, the result would have been different.
The distribution of hours in your own plant may be entirely different. Do not guess without measuring.
A part-load comparison is made with frame and power held the same (representative image).
How does a speed difference distort the comparison on fans and pumps?
A synchronous design has no slip, so at the same frequency it turns slightly faster than an induction motor, and a fan or centrifugal pump draws more power from this small speed increase. While a 4-pole induction motor runs at a rated speed of around 1465 rpm, for example, the synchronous motor turns at 1500 rpm.
According to the affinity laws, in a centrifugal machine flow changes with speed, head with the square of speed and power roughly with the cube of speed (general knowledge; confirm with the machine manufacturer). Even a small speed increase raises shaft power noticeably. When you measure the old and the new motor, record flow and pressure as well. A kW comparison is meaningless unless both are doing the same job.
In a drive-fed system the fix is simple. Speed is matched with the frequency setting and the comparison is made at the same operating point. In a direct-on-line replacement, the pulley ratio or pump impeller has to be reconsidered.
Example electric motors for lines running at part load
4-pole cast iron motors are common on variable-flow fan and pump lines. If your measurement showed that shaft power mostly stays around half of rated power, first check whether the next size down can handle the peak loads; then decide on the efficiency class. You can compare the power steps side by side in the HEM Motor electric motor shop.
160L-4: 15 kW, 1465 rpm, 27.3 A at 400 V, 97.8 Nm.
180M-4: 18.5 kW, 1470 rpm, 33.5 A at 400 V, 120.2 Nm.
200L-4: 30 kW, 1475 rpm, 53.8 A at 400 V, 194.2 Nm.
The efficiency class in which these models can be supplied is confirmed when ordering. The general features of the induction family are on the asynchronous electric motors page, and technical information including part-load data is in the 2026 technical catalogue.
If you have an analyser log and the nameplate of the existing motor, we can work out together which efficiency class makes sense for your load bands; sharing the nameplate photo through the nameplate submission page is enough. For the list of other power options, see our model page.
Frequently Asked Questions
If my motor always runs at full load, will the IE5 difference still be large?
At full load the loss difference between the two classes is narrower than at part load. For the decision, put your annual operating hours and energy cost into the same calculation method.
Does the nameplate efficiency also apply at part load?
No, the nameplate value reflects the measurement at rated load. Ask for the three-quarter, half and quarter load values from the manufacturer's data sheet.
For a motor running at half load, is it better to downsize or move up a class?
Starting torque and peak loads are checked first. If the smaller size covers them, downsizing is considered; if not, a motor with a flatter efficiency curve is considered; both can also be combined.
Should drive losses be included in the comparison?
Yes, if the synchronous design runs on a drive, the drive loss is added to the motor loss. For a fair comparison, measure the total power drawn from the grid.
HEM Motor Models Related to This Article
The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.
When an IE5 electric motor investment pays for itself depends largely on how many hours a year the motor runs and at what load: the annual energy difference is the loss difference ... More Details
An IE5 electric motor fits an existing base frame only after the IEC frame number, mounting type, foot hole spacing, shaft and flange data have been compared with the old motor; a ... More Details
The maintenance interval of an IE5 efficiency-class electric motor is calculated from operating hours, speed and ambient conditions rather than from the calendar, and the spare par... More Details
Panel planning for an IE5 electric motor starts once it is clear whether the motor will run on a drive or directly from the grid: magnet-based synchronous designs usually depend on... More Details
An IE5 electric motor makes sense on drives that run thousands of hours a year at high load, where energy cost weighs heavily in operating expenses and which are, more often than n... More Details
In an electric motor renewal, production downtime is costed by multiplying the number of hours stopped by that line's hourly downtime cost; the hourly cost in turn is the sum of it... More Details