Drive and Control Panel Planning for an IE5 Electric Motor

Drive and Control Panel Planning for an IE5 Electric Motor

Panel planning for an IE5 electric motor starts once it is clear whether the motor will run on a drive or directly from the grid: magnet-based synchronous designs usually depend on a frequency drive, and the panel is built around that drive's input protection, harmonic measures, cooling and motor cable. If a drive-free design has been chosen, the classic starting arrangement applies. Making this decision before ordering the motor saves drawing the panel twice.

Can an IE5 electric motor run without a drive?

Most IE5-level electric motors with a permanent magnet or reluctance rotor cannot run without a drive; a frequency drive is needed to reach synchronous speed and keep control. Designs that reach the IE5 level with a lower-loss induction build, however, can be connected directly to the grid.

This distinction changes the entire panel project. In a drive-fed arrangement, the contactor, thermal relay and star-delta group give way to the drive, its input protection and filters. In a drive-free arrangement, starting current, starting method and the motor protection relay are the main topics.

HEM Motor offers motors in the IE3, IE4 and IE5 efficiency classes.

For a given power and frame, which rotor design delivers the IE5 level and whether a drive is mandatory must be confirmed when ordering; start the panel drawing after that confirmation.

Which nameplate data are used when selecting a drive?

The drive is selected by the motor's rated current, rated voltage, motor type (induction or synchronous) and load character; looking only at the kW value is not enough. Two motors with the same kW can draw different currents, and a drive is limited by current.

  • Rated current and connection (400 V delta or 690 V star): the drive's continuous output current must be above this.
  • Motor type: for a permanent magnet synchronous motor, the drive must support that motor type and the motor parameters (such as inductance and back-EMF constant) must be entered.
  • Load character: variable torque is selected for fans and pumps, constant torque for conveyors and mixers; for heavy starts, the drive's short-time overload capacity is checked.
  • Speed range: if the motor will run for long periods at low speed with full torque, motor cooling is assessed separately.

With magnet motors, the drive runs a motor identification step at first commissioning. Because some drives can only partly perform this step with the load coupled, adding a time window in the commissioning plan when the motor can be turned unloaded makes the job easier (general knowledge; confirm with the drive manufacturer's instructions).

We have collected the general features of motors in this class on our IE5 Ultra Premium Efficiency Electric Motors page; the efficiency class in which a listed model is supplied is confirmed with the order.

Which protection and filter elements are planned on the panel's input side?

On the input side, a main switch or load-break switch, short-circuit protection and, where needed, an input reactor and EMC filter are planned to protect the drive and the grid. The ratings of these elements are set from the table in the drive manufacturer's manual. Figures for fuse or breaker ratings, cable cross-section and residual current device type are not given here; the project engineer calculates them from the drive input current, short-circuit power, cable length, installation method and ambient temperature. Knowing which information the calculation needs helps you collect the right data on site:

  1. Transformer rating and short-circuit current at the supply point (from the utility or the existing project).
  2. The drive's input current and the protection type recommended by the manufacturer.
  3. Cable route and length from the panel to the motor.
  4. Other drives fed from the same busbar and the state of the compensation panel.

Harmonics are a separate topic. In plants where several drives are fed from the same transformer, current harmonics can stress compensation capacitors; that is why an input reactor, a DC link choke or an active filter is assessed at the project stage. Check whether the compensation panel has harmonic-filtered (detuned) steps.

How should the motor cable and earthing be planned?

The cable from drive to motor is chosen as a shielded, symmetrical type, the shield is earthed at both ends with a 360-degree clamp, and the cable route is kept apart from control cables. These three measures reduce both bearing currents and the noise that spreads to nearby measurement lines. As the cable gets longer, voltage peaks at the motor terminals grow. Our three-phase series are suitable for speed control with a frequency converter; for long periods at low speed with full torque an external fan may be needed; if the drive–motor cable is long, a dv/dt or sine filter is considered; these conditions are stated when ordering.

An equipotential bond between the motor frame and the driven machine lowers the chance that drive-induced shaft voltages discharge through the bearing. If an insulated bearing or shaft grounding brush is required, state it in the order and get confirmation.

Three-phase electric motor and terminal box
In a drive-fed system, the shield clamp and earthing in the terminal box matter as much as the panel (representative image).

Prices and technical data are on the product pages; choose a model and order online.

Which signals and protection functions belong on the control side?

On the control side there should at least be emergency stop, run enable, speed reference, fault feedback and winding temperature monitoring signals. The drive's own software protections do not replace these signals; they complement them.

FunctionWhere it comes fromPlanning note
Emergency stop and safe torque offEmergency stop button, safety relay, the drive's STO inputThe category is set by the machine safety assessment
Winding temperaturePTC or PT100 sensor in the motorThe sensor is an order option; it connects to a drive input or a separate relay
Speed referencePLC analogue output or fieldbusDefine how the drive behaves if the fieldbus link is lost
Fault and ready statusDrive relay outputsReading the fault code into SCADA speeds up diagnosis
Anti-condensation heaterSeparate supply from the panelInterlocked to switch on while the motor is stopped; an order option

The need for a bypass should also be discussed from the start. With an induction motor, a bypass contactor can be installed to put the motor straight on the grid if the drive fails; with a magnet synchronous motor this route is usually not possible. That is why a spare drive or spare motor option is assessed on lines that cannot tolerate downtime.

Why should heat and layout inside the panel be calculated in advance?

A drive turns a small but not negligible part of its power into heat, and if this heat is not removed from the panel the drive derates or trips. Panel size and the need for a fan or air conditioner are therefore calculated together with the drive loss figure and the ambient temperature. Hypothetical example: if the drive manual states a loss of a few hundred watts at full load, the panel is chosen so that this heat is removed through the panel surface and by fan air. In a boiler room that exceeds 40 °C in summer, the same panel may not be enough. Place the drive in the panel to suit vertical airflow, do not put heat sources above it, and add maintenance of the filtered fan inlets to the periodic plan.

Example electric motors for drive-fed lines

In panel planning, motor current directly sets the drive size.

The nameplate values of the 4-pole cast iron models below can be used as starting data for selecting the drive and input protection; other power steps are listed in our electric motor shop.

  • 180L-4: 22 kW, 1470 rpm, 39.7 A at 400 V, 142.9 Nm.
  • 225S-4: 37 kW, 1485 rpm, 66.1 A at 400 V, 237.9 Nm.
  • 250M-4: 55 kW, 1485 rpm, 97.6 A at 400 V, 353.7 Nm.

The efficiency class and sensor options in which these models can be supplied are confirmed when ordering. General information on the cast iron family is on the cast iron electric motors page, and thermal relay and breaker logic is explained in our motor protection article.

If you would like to settle the motor's rotor design and drive requirement before your panel project is drawn, share the existing motor nameplate or the project load list through the nameplate submission page, and we will work out the current and sensor details together. All power steps are on the HEM Motor product page.

Frequently Asked Questions

Can I use my existing induction motor drive with an IE5 synchronous motor?

Only if the drive supports permanent magnet synchronous motor control and its current capacity is sufficient. Get written confirmation of motor type support from the drive manufacturer.

Is a thermal relay needed in a drive-fed system?

In most applications the drive's motor overload protection does the thermal relay's job. A PTC or PT100 sensor is still recommended to monitor winding temperature directly.

Can a contactor be placed between the drive and the motor?

It can, but it must not open or close while the drive is running; the interlock is built accordingly. Because a rotating magnet rotor generates voltage, confirm that the motor has stopped before maintenance.

Should harmonic measurement be included in the panel plan?

Yes, in plants where several drives are fed from the same transformer. Measurements before and after commissioning put compensation and filter decisions on a numerical footing.

HEM Motor Models Related to This Article

The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.

22 kW 1500 rpm Cast Iron Frame Electric Motor 180L-4

180L-4

22 kW · 1500 rpm

  • Cast iron frame · IEC 180L
  • 1470 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$901.75 (€825.30)

View product
37 kW 1500 rpm Cast Iron Frame Electric Motor 225S-4

225S-4

37 kW · 1500 rpm

  • Cast iron frame · IEC 225S
  • 1485 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$1,497.78 (€1,370.80)

View product
55 kW 1500 rpm Cast Iron Frame Electric Motor 250M-4

250M-4

55 kW · 1500 rpm

  • Cast iron frame · IEC 250M
  • 1485 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$2,025.96 (€1,854.20)

View product

Similar Articles