How Is the Permissible Radial Load Queried When Ordering an Electric Motor?

How Is the Permissible Radial Load Queried When Ordering an Electric Motor?

When ordering an electric motor, the permissible radial load is queried by stating together the size of the belt or chain force, the distance from the shaft end at which it acts and the required bearing life. Without these three pieces of information the supplier cannot give a single figure; the quotation should also state which distance and life the given value applies to.

Where does radial load on the shaft come from?

Radial load is the force that pushes the shaft sideways and acts perpendicular to its axis. In a pulley belt drive it is the belt tension, on a chain sprocket the chain pull, on a pinion the gear force that pulls the shaft sideways.

On a pump connected directly with a coupling this load is small, whereas on a pulley-driven fan, a belt-driven jaw crusher or a chain-pulled conveyor radial load becomes the item that alone decides the life of the front bearing and overshadows the rest of the motor selection.

This force is carried by the front bearing.

The further from the shaft end it acts, the more the moment on the bearing increases. Geometry dictates this; the same belt tension strains the bearing little when the pulley sits close to the shaft shoulder and much more when it is slid towards the shaft end.

What data are used to estimate belt force?

In a belt drive the radial force is found roughly by dividing the transmitted torque by the pulley radius and multiplying by a tension factor: F ≈ (2 × T / d) × k. Here T is motor torque, d the pulley diameter and k a factor depending on belt type and tensioning method (general information; the belt manufacturer's catalogue is the basis for the factor).

What the formula tells the site is simple. Small pulley, big force.

A hypothetical example: on a machine of 15 kW running at 1465 rpm, shaft torque is around 98 Nm. If the same torque is transmitted through a pulley of half the diameter, belt force roughly doubles; the machine builder who picks a small pulley to save space strains the bearing without realising it.

On chains the tension factor is usually smaller than on belts, but because sprocket diameter is small the force can still come out high. On a pinion connection the radial and axial components of the gear force are calculated separately. All suitable steps can be seen in the HEM Motor store.

Why is the distance at which the force acts asked separately?

The manufacturer's permissible radial load value is given for a specific point; usually the middle of the shaft extension or a set distance from the shaft shoulder. If the pulley's real position differs from that point, the permissible value changes too.

The most common error on site is sliding the pulley outwards on the shaft. When belt alignment does not line up, the pulley is loosened and pushed towards the shaft end; the force stays the same but the load on the bearing rises. The error is invisible. The noise only comes months later.

So the order states the pulley hub width and the distance from the shaft shoulder to the pulley centre. Shaft dimensions and key data by frame are in the technical drawings, general data in the 2026 catalogue.

How does bearing life enter the query?

Permissible radial load is defined for a given bearing life. As the life expectation lengthens, the permissible load decreases; if a shorter life is accepted, a higher load is allowed.

Life is usually given in hours with a statistical definition (general information; the definition and calculation method vary with the bearing standard). How many hours in total the pump turns in a year and how many years the bearing is to be left untouched are the inputs to this calculation.

A fan running day and night and a conveyor working a few hours per shift see very different lives at the same radial load. When the order states daily operating hours and the expected maintenance interval, the supplier can use the right life value.

Which bearing type and brand HEM motors use and whether the bearings are regreasable has not been verified in this article; it must be confirmed with the order.

Three-phase electric motor with keyed shaft end visible
Radial load changes with the pulley's position on the shaft; distance and key size are read from the technical drawing (representative image).

Prices and technical data are on the product pages; choose a model and order online.

What information should go on the query form?

The information the supplier needs to answer correctly in one go fits in a short table:

InformationWhere is it taken from?Why is it needed?
Drive type (belt, chain, pinion)Machine drawingSets the tension factor
Pulley or sprocket diameterDimension on the pulleyChanges the force directly
Distance from shaft shoulder to pulley centreMounting dimensionChanges the moment on the bearing
Direction of force (up, down, horizontal)Machine layoutAffects bearing and frame loading
Daily operating hours and expected lifeOperating planSets the permissible load value

Once this table is filled in, the supplier's answer of "standard bearing is enough" or "a reinforced front bearing may be needed" rests on concrete data. The guide on information to give when requesting a quote follows the same logic for order preparation.

Which options are considered if radial load comes out high?

The first option is mechanical: moving the pulley closer to the shaft shoulder or increasing pulley diameter, because both reduce the load on the bearing without changing the motor at all and are often solved with a pulley order.

The second option is one frame up.

As the frame number grows, the shaft thickens and the front bearing grows too; permissible radial load usually rises noticeably. The price is size. Foot spacing and shaft height change. On an existing machine this switch may require redrilling the base or fitting an adaptor plate in between; on a newly designed machine deciding at the drawing stage keeps the job simple. That is why the radial load question should be asked at the machine builder's design desk, while the pulley diameter is being chosen.

The third option is separate bearing support. On crushers and mills with heavy belt loads, the pulley is mounted not on the motor shaft but on a jackshaft with its own bearings, and the motor is connected to the jackshaft with a flexible coupling.

Mounting style also matters. On a foot-mounted motor the frame transfers the force to the chassis; with flange-only mounting the flange and its bolts must carry the load as well. Mounting arrangements (foot, flange, vertical) are offered according to frame; the actual flange size is matched with the drawing at order.

Which motors are often queried for belt drives?

4-pole cast iron steps often met on pulley-driven fans, crushers and conveyors (all 400/690 V):

  • 160L-4: 15 kW; 97.8 Nm at the shaft, 1465 rpm.
  • 180L-4: 22 kW; 142.9 Nm at the shaft, 1470 rpm.
  • 225S-4: 37 kW; 237.9 Nm at the shaft, 1485 rpm.

The torque in the list is the starting point for the belt force calculation; frame and shaft options are gathered on the asynchronous electric motors page. The permissible radial load of these models is confirmed together with the distance and life data on the query form.

Send the pulley diameter, hub width, distance from shaft shoulder to pulley centre and daily operating hours through the contact page; we will check the radial load together and settle the right frame from the sales list. Overload relay setting is a separate topic; the motor protection guide covers it.

Frequently Asked Questions

What if the catalogue does not state radial load?

Ask the manufacturer, stating pulley diameter, distance, direction of force and expected life. A single figure given without this information does not represent the real application.

Is it a problem to slide the pulley towards the shaft end?

Even if the force stays the same, the moment on the bearing rises and life shortens. Belt alignment should be corrected by aligning the motor on its base, not by sliding the pulley.

Does a chain drive create less radial load than a belt?

The tension factor is usually lower, but because sprocket diameter is small the force can still be high. In both cases the calculation is made with torque and diameter.

HEM Motor Models Related to This Article

The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.

15 kW 1500 rpm Cast Iron Frame Electric Motor 160L-4

160L-4

15 kW · 1500 rpm

  • Cast iron frame · IEC 160L
  • 1465 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$665.08 (€608.69)

View product
22 kW 1500 rpm Cast Iron Frame Electric Motor 180L-4

180L-4

22 kW · 1500 rpm

  • Cast iron frame · IEC 180L
  • 1470 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$901.75 (€825.30)

View product
37 kW 1500 rpm Cast Iron Frame Electric Motor 225S-4

225S-4

37 kW · 1500 rpm

  • Cast iron frame · IEC 225S
  • 1485 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$1,497.78 (€1,370.80)

View product