When an electric motor is transported, the shaft end and the flange face are protected separately against impact, scratches, rust and vibration marks. Rust preventive is applied to the shaft end and a protective sleeve or tape is fitted with the key left in place; the flange face and spigot are covered with a clean cover, and the motor is carried and secured by its feet or lifting eye, never on the shaft end or flange.
Why are the shaft end and flange so sensitive?
The shaft end is a ground surface on which the coupling or pulley hub sits. A small dent on it makes fitting the hub difficult; a hub driven on by force passes the blow to the bearing. If the edge of the keyway is crushed, the key either does not seat or seats with play.
On the flange, the sensitive areas are the spigot and the mounting face. The motor sits on the gearbox or machine with this surface and axial alignment comes from here. A burr or scratch on the face stops the flange bedding fully. The result is a small angular deviation of the shaft axis.
These small defects may go unnoticed at the first start. Within weeks they come back as bearing noise, coupling wear or a leak at the gearbox input seal. The mounting type of each frame is shown separately on the model cards of the motor sales page.
Which damage is most common during transport?
Most damage comes from loading, unloading and sliding in the truck bed.
Damage
How it happens
How it is noticed on site
Dent on the shaft end
The motor tips onto its shaft end or the shaft hits another load
Hub jams when fitting, a raised spot felt by finger
Crushed keyway edge
The key is removed and left loose, takes a knock
Key will not seat by hand
Scratch on the flange face
Motor laid on its flange face, rubs on the pallet
Shiny lines when held to the light
Rust on the shaft end
Protective oil wiped off, motor waits in a damp place
Brown stains, hub jams
Bearing marks
Vibration on a stationary shaft over a long journey
Hum or irregular noise at first start
Broken terminal box
Motor lifted by the box or load placed on it
Cracked cover, broken cable entry
The last two rows lie outside shaft and flange but come from the same handling mistake. That is why the protection plan covers the whole motor.
How is the shaft end prepared for transport?
On motors leaving the factory, the shaft end usually comes with protective oil and a plastic sleeve. If a motor is removed and shipped again, this protection is rebuilt.
Wipe the shaft end with a clean cloth; remove old grease, dust and metal particles.
Apply a thin layer of rust preventive oil or wax-based protector.
Refit the key and secure it with tape; a loose key gets lost or crushes the keyway.
Fit a plastic sleeve, thick cardboard tube or several layers of foam over the shaft end; cover the tip too.
Secure the sleeve with tape; try not to stick tape directly on the ground surface, it may leave residue.
If a pulley or coupling hub is to be shipped fitted on the shaft, the hub is protected as well, and the motor is placed horizontally with the hub side supported so the hub does not bend the shaft.
In crated shipments the motor is secured by its feet; forklift tines go under the crate base, not under the motor frame (representative image).
How is the surface protected on a flange motor?
On B5 and B14 flange motors, the flange face and spigot are the main surfaces to protect. In the foot-and-flange B35 design, both feet and flange need care.
A workable method: the flange face is wiped, a thin rust preventive applied, and a hard cardboard or plywood cover cut to the flange diameter is placed over it and secured with a few bolts through the mounting holes or with tape. The cover must not press on the flange spigot.
A flange motor is never laid on its flange face. If it is to stand vertically with the flange facing down, a soft board goes underneath and the motor is tied so it cannot tip over. The safest position is horizontal, supported under the feet or frame.
The motor is lifted by the lifting eye on its frame or from under its feet. The lifting eye is for the motor alone; if a gearbox, pump or base is attached, the whole group is not lifted by the eye.
On a pallet or in a crate, the motor is fixed through its foot bolt holes to timber blocks or to the pallet. Lashing straps are not passed over the shaft end, fan cover or terminal box. Spacers go between motors; two motors are not stacked with shaft ends facing each other.
In the truck the pallet is secured to the bed; a pallet that slides under braking can drive the motor's shaft end into the side wall. Forklift tines go under the pallet or crate base, not under the motor frame.
Are extra measures needed for long journeys and long storage?
Yes. On a long journey, while the shaft stands still, vehicle vibration can make the bearing balls strike the same spot in the races. This is called false brinelling. The symptom is a hum heard when the motor is first started.
On large frame motors, the manufacturer sometimes locks the shaft with a transport lock. If there is such a lock, it must be removed before installation; a motor run with the lock in place strains the bearing. Without a lock, carrying the pallet on a vibration-damping base helps.
Motors that will wait long in storage are kept in a dry, enclosed place. Every few months the shaft is turned by hand a few revolutions; this redistributes the grease and lets the balls settle in a different spot. In damp stores, winding insulation resistance is measured before installation.
What should be checked on receipt?
A check at the moment of receipt makes it possible to tell whether damage occurred in transport or during installation.
Is there a dent, wet patch or hole on the outside of the packaging?
Is the shaft end sleeve in place, is the key present?
Is the flange cover in place, is there a scratch on the flange face?
Is the fan guard or terminal box cracked?
Does the shaft turn freely and quietly by hand?
If damage is seen, photos are taken and a note made on the delivery document. If there is adhesive or rust residue on the shaft end at installation, it is cleaned with a fine cloth; abrasive paper is not used, as it spoils the shaft size.
Medium frame motors such as the cast iron 112M-4 (4 kW), 132M-4 (7.5 kW) and 160M-4 (11 kW) are among the models often shipped in foot or flange designs. B3, B5, B14, B34, B35 and vertical V1/V3/V5/V6/V15 are offered depending on frame; flange size is confirmed with the order. For other power steps, browse the electric motor shop.
The general purpose series is grouped under the industrial motor family. Stating the mounting type, the equipment the motor will be fitted to and the transport conditions with your order makes it easier to prepare the packaging accordingly.
If you have any doubt about the shaft end or flange of a motor you received, send the photos through our contact page; we will look at it together before installation. For model and frame comparison you can use the HEM Motor product list.
Frequently Asked Questions
Should the protective oil on the shaft end be cleaned off before installation?
Yes. It is wiped with a clean cloth; no thick oil or adhesive should remain on the surface where the hub sits. If a solvent is used, it should not touch seals or lip seals.
Can the motor be lifted together with the gearbox by its lifting eye?
No. The eye is designed only to lift the motor itself. For lifting as a group, the lifting points of the gearbox or base are used.
What if the motor hums at first start after transport?
Stop the motor and listen while turning the shaft by hand. If the hum persists, there may be bearing damage; contact us with photos and a sound recording.
Does a light scratch on the flange face affect installation?
A scratch or burr that raises the surface stops the flange bedding fully. A slight burr can be carefully removed with a flat oilstone; if the scratch is deep, consult the manufacturer before installation.
HEM Motor Models Related to This Article
The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.
In an electric motor renewal, production downtime is costed by multiplying the number of hours stopped by that line's hourly downtime cost; the hourly cost in turn is the sum of it... More Details
A no-load run during electric motor acceptance reveals wrong connection, reverse rotation, current imbalance between phases, bearing noise, vibration and mechanical damage from tra... More Details
Turning the shaft by hand when an electric motor is delivered is the fastest check for damage to the bearings, shaft or rotor during transport: the shaft of a healthy motor should ... More Details
In electric motor procurement, model revisions are tracked by recording in the order, beside the motor's power and speed, its model code, housing material, mounting arrangement, an... More Details
In a framework purchase agreement for electric motors, delivery call-offs are planned once the annual total quantity and price terms are fixed, so that motors are requested in port... More Details
In an electric motor requirements list, annual quantity is defined as the total 12-month consumption for each model, and batch size as the quantity delivered at once in one order, ... More Details
We use necessary and optional cookies to improve your experience, enhance content and analyse traffic. Under the GDPR, optional (analytics/marketing) cookies are only used with your explicit consent. Please choose your preference below.