In an electric motor's technical drawing, overall length is the largest dimension the motor occupies from one end to the other: it is usually measured from the rear face of the fan cover to the face of the shaft end. Mounting length, on the other hand, is the distance between the references that attach the motor to the machine; on a foot-mounted motor the foot holes and shaft shoulder are used, on a flange motor the flange face and the shaft end. One tells you the space the motor will fill, the other where the connection points will fall.
Which dimension on the drawing represents what?
On IEC motor dimension drawings each dimension is shown with a letter code, and the meaning of the letters is given in the key table at the front of the manufacturer's catalogue. In most catalogues overall length appears as a single letter, as the outermost dimension from the fan cover to the shaft end. Shaft length, the distance from shaft shoulder to foot hole, the longitudinal distance between foot holes and the flange dimensions are shown with separate letters (general information; confirm the letter meanings in the key table of the catalogue you use).
A common mistake is to assume the letters mean the same thing from one manufacturer to another. The basic connection dimensions are defined in the IEC standard, but outer frame dimensions such as overall length and terminal box position can vary by manufacturer. Two motors with the same frame number may fit the base exactly while one is longer than the other.
Why does overall length matter on site?
It is a matter of space. If the motor is squeezed between a cabinet, guard or wall and a coupling, the decisive dimension is overall length, even when all connection dimensions fit. There is one more condition. Space must remain behind the fan cover for air intake, because a motor with its cover against a wall cannot draw cooling air and soon overheats.
On site this dimension causes most trouble in renewals. The old motor is removed, the new motor sits on the base, the foot holes line up; but the fan cover touches the guard plate behind. Or the shaft end is in the right place but the terminal box hits the cable tray on the side wall. That is why overall length is read not alone but together with terminal box height and position. Is the box on top or at the side? The drawing shows this, which way the cover opens and where the cable entry faces.
From which references is mounting length measured?
On a foot-mounted (B3) motor the reference is the foot holes. The distance from the shaft shoulder to the nearest foot hole axis determines where the shaft end will fall relative to the coupling or pulley. Whoever drills the base will also ask for the longitudinal distance between foot holes.
On a flange (B5) motor the reference is the flange contact face. The distance from the flange face to the shaft end shows how far the shaft will enter the gearbox or pump hub. The frame length behind the flange stays outside the machine and matters only for total clearance.
On a foot-and-flange (B35) motor both references apply together. The positional relationship between foot and flange is taken from the drawing. Both are fixed. The frame must not be stressed.
Frame length and overall length can change within the same power family (representative image).
Prices and technical data are on the product pages; choose a model and order online.
How do the S, M and L frame letters affect length?
In an IEC frame number the figure defines the shaft height, and the following letter S, M or L defines the longitudinal distance between foot holes: short, medium, long. At the same shaft height, an S frame motor has a shorter foot span than an L frame motor.
When the letter changes, overall length usually changes too, because a longer foot span generally means a longer core and frame. Shaft end dimensions, on the other hand, are usually kept within the same shaft height; most renewal cases where the coupling side fits perfectly but the fan cover presses against the plate or wall behind arise from exactly this difference.
Dimension
What does it determine?
When is it checked?
Overall length
The largest length the motor occupies
Fitting between cabinet, guard plate or wall, fan air intake
Longitudinal distance between foot holes
Position of base holes
Making a new base, reusing the same base in a renewal
Shaft shoulder to foot hole distance
Position of the shaft end relative to coupling or pulley
Coupling gap, belt alignment
Flange face to shaft end distance
Insertion length of the shaft into the mating hub
Gearbox and pump connections
Terminal box position and height
Side and top clearance
Cable tray, cover opening direction
How can dimension confusion be avoided in purchasing?
Power and speed are not enough. Frame number, mounting type and the limiting dimensions in the machine should be stated together. If the existing motor is on site, a photo of its nameplate plus the overall length and base hole spacing taken with a tape measure make things much easier.
There is one detail to watch when measuring: overall length is taken from the face of the shaft end to the rearmost point of the fan cover; projections on the cover and any separate fan are included. If a pulley or coupling is fitted on the shaft, its length is noted separately. For the machine builder things are a little different. At the design stage the manufacturer's technical drawing is the basis and a small margin is added to overall length; the drawing of the model ordered is approved by comparing it with the preliminary information.
Which example models illustrate these dimensions?
Three cast iron models are listed below to show the effect of a different frame letter at the same shaft height and of the next frame up. IP55 protection and class F insulation are common to all three. For the meanings of the dimension letters, see the 2D technical drawings page and for the whole series the 2026 technical and product catalogue; other power steps are listed in the HEM Motor shop.
90S-4: 1.1 kW, 1445 rpm, 2.48 A at 400 V, rated torque 7.27 Nm. The short (S) foot span version of frame 90.
90L-4: 1.5 kW, 1445 rpm, 3.30 A at 400 V, rated torque 9.91 Nm. Long (L) foot span at the same shaft height; the base hole spacing differs from the 90S-4.
100L-6: 1.5 kW, 949 rpm, 3.59 A at 400 V, rated torque 15.1 Nm. The next frame up for lower speed at the same power; shaft height and overall length change.
If you send the dimensions of the space in your machine and the nameplate of the existing motor via our contact page, we can decide together which model's drawing you should look at. The current model information is on our sales page.
Frequently Asked Questions
Do two motors with the same frame number have the same overall length?
Not always. Connection dimensions are standard, but fan cover, terminal box and outer frame shape can vary by manufacturer. Overall length must always be checked on the drawing of the chosen model.
Does overall length include a pulley or coupling?
The overall length in the catalogue shows the bare motor. The length of elements fitted on the shaft, such as a pulley, coupling or brake, is added separately.
Which dimension matters for a gearbox connection on a flange motor?
The distance from the flange contact face to the shaft end and the flange spigot dimensions. These values are compared with the gearbox manufacturer's input dimensions.
Where can I find the dimensions on the technical drawing?
For HEM Motor models, 2D technical drawings prepared by frame and the 2026 catalogue are on the website; the relevant drawing is approved before ordering.
HEM Motor Models Related to This Article
The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.
In an electric motor renewal, production downtime is costed by multiplying the number of hours stopped by that line's hourly downtime cost; the hourly cost in turn is the sum of it... More Details
A no-load run during electric motor acceptance reveals wrong connection, reverse rotation, current imbalance between phases, bearing noise, vibration and mechanical damage from tra... More Details
Turning the shaft by hand when an electric motor is delivered is the fastest check for damage to the bearings, shaft or rotor during transport: the shaft of a healthy motor should ... More Details
When an electric motor is transported, the shaft end and the flange face are protected separately against impact, scratches, rust and vibration marks. Rust preventive is applied to... More Details
In electric motor procurement, model revisions are tracked by recording in the order, beside the motor's power and speed, its model code, housing material, mounting arrangement, an... More Details
In a framework purchase agreement for electric motors, delivery call-offs are planned once the annual total quantity and price terms are fixed, so that motors are requested in port... More Details