Why Should You Ask for a Starting Torque Table When Buying an Electric Motor?

Why Should You Ask for a Starting Torque Table When Buying an Electric Motor?

When buying an electric motor you should ask for the starting torque table, because the kW and speed on the nameplate only describe the motor's power in continuous operation; whether the machine can move from standstill is decided by starting torque, minimum torque and breakdown torque. Two motors of the same power can have different values here, and on a hard-starting machine the wrong choice means the motor does not turn at all or the protection keeps tripping.

Which values are in a starting torque table?

In the manufacturer's catalogue, torque values for each model are usually given as a ratio of rated torque. A typical table contains these columns:

ValueSymbolWhat it describes
Rated torqueTNTorque that can be delivered continuously at plate power and speed
Starting (locked rotor) torqueTA/TNTorque at the shaft at zero speed and full voltage
Minimum (pull-up) torqueTS/TNLowest point of the torque curve during acceleration
Breakdown (maximum) torqueTK/TNHighest torque the motor can give without stalling
Starting currentIA/INCurrent drawn from the supply at the first moment divided by plate current

Rated torque is calculated with this relation:

TN [Nm] = 9550 × P [kW] / n [rpm]

The ratios are multiplied by this value to convert them to Nm (general information; confirm the ratios on the model's catalogue page).

Why is plate power not enough?

The nameplate shows the load the motor can carry continuously in thermal terms. Starting, on the other hand, is a short but demanding moment. At this moment the machine has to overcome static friction, inertia and sometimes the weight of a full hopper.

Consider an example. A loaded conveyor, a jammed mixer or a piston compressor under pressure needs torque clearly above rated torque at start. If the motor's starting torque is below this, the rotor does not turn; the winding quickly overheats under locked rotor current and the thermal relay or breaker cuts the line.

Two motors with identical nameplates can differ in cage bars, slot shape and rotor resistance. One may be optimised for high starting torque, the other for high efficiency. In a selection made without asking for the table, this difference only becomes clear on site.

Cast iron electric motor for a hard-starting drive
On hard-starting machines the motor is chosen by its torque table as much as by plate power (representative image).

Why does minimum torque matter?

The torque curve of an induction motor is not flat. It starts at a certain value at standstill, sags somewhat while accelerating, then climbs to its peak and comes back down as it approaches rated speed. The dip in the middle is called pull-up torque.

If the torque the load demands rises above this dip, the motor cannot complete acceleration. It hangs at some speed halfway; the current it draws does not fall and the coils get hotter every second. Such hanging is seen especially with high-inertia loads such as fans and mills and on sites where voltage drops.

A mill example makes this easier to picture. The heavy stone accelerates slowly at start; the motor turns easily in the first second, but when the curve enters the dip at a few hundred rpm the resistance of the load may exceed the torque curve. All the operator sees is the machine grumbling for a while and then tripping.

A motor with a seemingly high starting torque can still cause trouble if its pull-up torque is low. That is why the table is read for minimum torque as well as starting torque.

How does voltage drop change the table?

The torque ratios in the catalogue apply at rated voltage. In an induction motor torque changes with the square of the applied voltage. If voltage drops by 10% at start, torque falls by about 19%.

On sites with long cables, plants with weak transformers or systems fed by a generator, starting current can lower voltage noticeably. If this condition is reported at the purchasing stage, the motor is chosen with a torque margin.

The starting method has the same effect. In star-delta, torque drops to roughly one third in the star position. With a soft starter, torque falls together with voltage. When reading the table, the starting arrangement in the panel must be taken into account too.

Prices and technical data are on the product pages; choose a model and order online.

How is the table used in purchasing?

  1. Find out the torque the machine needs at start from the machine manufacturer or a similar application.
  2. Calculate the motor's starting and minimum torque in Nm.
  3. Reduce these values for voltage drop and starting method.
  4. If the remaining value is above the torque the load needs with a reasonable margin, the motor is suitable.
  5. Assess the starting current ratio together with the supply and protective devices.

On the protection side, starting current and duration directly affect the choice of thermal relay and breaker. This topic is covered separately in the motor protection guide. The torque and current values of all models are gathered in the technical and product catalogue; to compare by power and speed you can use the electric motor shop.

For which applications must the table be requested?

  • Belt and bucket conveyors that stand loaded,
  • Machines that break stone, grind or knead dough,
  • Piston compressors and positive displacement pumps,
  • High-inertia fans and centrifuges,
  • Sites fed by a generator or a long line.

In these applications an order given with power and speed alone is the main cause of the most frequent site complaint: "the motor will not start".

Example models and their rated torques

Three four-pole cast iron steps often found on hard-starting drives:

  • 180M-4: 18.5 kW, 1470 rpm, 33.5 A at 400 V, 120.2 Nm.
  • 200L-4: 30 kW, 1475 rpm, 53.8 A at 400 V, 194.2 Nm.
  • 225M-4: 45 kW, 1485 rpm, 80.2 A at 400 V, 289.4 Nm.

Rated torques are given here; the three torque ratios and the current factor are read on each product's own catalogue page. The models have 400/690 V Δ/Y windings, IP55 protection and insulation class F. For every step of the cast iron series see the cast iron frame models category. For frame dimensions see the technical drawings.

If you share the machine type, the load condition at start, the starting method and the supply condition via our contact page, we will choose the suitable motor together using the torque table. Current prices by model are listed on the HEM Motor sales page.

Frequently Asked Questions

Is a motor with high starting torque always better?

No. High starting torque often comes with higher starting current and is unnecessary for light-starting loads. The choice is made according to the load's needs.

What should be done if there is no torque table?

Ask the manufacturer for a data sheet for the model. If data cannot be obtained, calculate with standard values for similar power and pole number, but keep the margin wide.

Does a frequency converter solve the starting torque problem?

In most cases yes; a converter can give torque around rated torque at low frequency. However, the converter's current capacity must also be chosen for the starting need.

What does breakdown torque show?

It shows the highest momentary strain the motor can withstand before stalling. It helps to understand how much margin the motor leaves during short load surges.

HEM Motor Models Related to This Article

The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.

18.5 kW 1500 rpm Cast Iron Frame Electric Motor 180M-4

180M-4

18.5 kW · 1500 rpm

  • Cast iron frame · IEC 180M
  • 1470 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$856.68 (€784.05)

View product
30 kW 1500 rpm Cast Iron Frame Electric Motor 200L-4

200L-4

30 kW · 1500 rpm

  • Cast iron frame · IEC 200L
  • 1475 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$1,211.23 (€1,108.54)

View product
45 kW 1500 rpm Cast Iron Frame Electric Motor 225M-4

225M-4

45 kW · 1500 rpm

  • Cast iron frame · IEC 225M
  • 1485 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$1,656.00 (€1,515.60)

View product

Similar Articles