Shaft end load on an asynchronous electric motor is the radial force that the belt pull on the pulley places on the shaft and, through it, on the drive-end bearing; the closer the pulley sits to the shaft shoulder, the smaller the force carried by that bearing. A drive set up without considering belt tension, pulley size and the hub position on the shaft together is the most common reason for early overheating of the drive-end bearing.
Below we explain how the force is calculated, how pulley position affects the bearing and which signs reveal excessive load in the field, using a hypothetical example.
Where does shaft end load come from and how does it affect the bearing?
Shaft end load comes from the element through which the motor transmits power, that is the pulley, gear pinion or chain sprocket, and acts perpendicular to the shaft. On a pump connected directly through a flexible coupling this force is very small; on a belt-driven fan, crusher or compressor it reaches a significant value that grows with motor power.
The rotor is carried between two bearings. Because the pulley sits at the shaft end, outside the drive-end bearing, the force acts like a lever: the drive-end bearing carries both the load from the pulley and the extra load produced by this lever, while the non-drive-end bearing takes a light reaction in the opposite direction. That is why most failures in belt drives start at the bearing on the shaft side of the motor. The series on the three-phase asynchronous electric motors page can also be connected to belt drives with a B3 foot-mounted frame; what decides the outcome is the size of the force and the point where it is applied.
How is the radial force calculated in a belt drive?
The radial force is calculated by multiplying the effective pull, found by dividing motor torque by the pulley radius, by a belt factor. The formula is:
Fe = 2 × T / d and Fr ≈ Fe × k
Here T is the motor torque at the shaft (Nm), d is the effective pulley diameter (m) and k is the belt factor that also includes pre-tension. For V-belts k is usually taken between 1.5 and 2.5; it differs for flat and toothed belts (general information; confirm with the belt manufacturer's catalogue).
Hypothetical example: a 7.5 kW, 1460 rpm electric motor delivers about 49.1 Nm of torque at its rated point. Suppose a 125 mm diameter pulley is used at the shaft end. Fe = 2 × 49.1 / 0.125 ≈ 786 N. Taking a belt factor of 2, the radial force on the shaft is about 1570 N.
If the pulley on the same motor is reduced to 100 mm, Fe rises to about 982 N and the radial force to around 1960 N. In other words, shrinking the motor pulley to hit the machine speed directly increases the load on the bearing. Where possible, the drive ratio is achieved by enlarging the pulley on the machine side.
Where should the pulley be fitted on the shaft end?
The pulley should be fitted with its hub as close as possible to the shaft shoulder, seated along the full length of the key, and it must not overhang the shaft end. As the load centre of the pulley (the middle of the belts) moves outward, the load on the drive-end bearing increases.
A simple ratio shows this. If the distance between the bearings is L and the distance from the drive-end bearing to the belt centre is x, the load on the drive-end bearing is approximately:
Ffront ≈ Fr × (L + x) / L
Hypothetically, with x = 0.3 L the drive-end bearing carries 1.3 × Fr. If the pulley hub is turned the wrong way and the belt centre moves to x = 0.6 L, the load rises to 1.6 × Fr. In ball bearings, life is roughly inversely proportional to the cube of the load; since 1.6 / 1.3 ≈ 1.23 and 1.23³ ≈ 1.86, the calculated bearing life drops by nearly half purely because of where the pulley sits (general information; confirm with the bearing manufacturer's calculation method).
The permissible shaft end force published by manufacturers is defined for a load applied at a particular point on the shaft; as the force moves outward, this limit becomes smaller. Shaft end dimensions by frame are on the technical drawings page; do not order without comparing the pulley width with that drawing. You can see how many models are listed for each frame and power in the electric motor shop.
The pulley hub should sit along the full key and stay close to the shaft shoulder (representative image).
Prices and technical data are on the product pages; choose a model and order online.
Decision table by pulley position, diameter and tension
Condition seen on site
Effect on the drive-end bearing
Correction
Pulley hub fitted backwards, belts outside the shaft end
Lever arm lengthens, load rises clearly
Turn the hub round, bring the belt centre towards the shoulder
Small motor pulley, machine pulley not large
High belt pull
Achieve the ratio by enlarging both pulleys together
Belt does not deflect at all when pressed by hand
Excess pre-tension, constant load
Reduce to the manufacturer's value with a tension gauge
Belt squeals and slips on start-up
Low tension, belt heats up
Increase tension, check the pulley grooves
Pulleys not in the same plane
Axial force and edge wear
Align with a straightedge or laser
Belt tension should not be set by eye. Two methods are used in practice: pressing the middle of the span with a set force and measuring the deflection, or using a tension gauge that reads the belt's vibration frequency. The belt manufacturer's table tells you which force and deflection are correct. New belts stretch during their first running hours, so tension is checked again after a while.
What signs reveal excessive radial load in the field?
The clearest sign is that the bearing housing on the shaft side runs noticeably hotter than the one on the fan side. Once the motor has reached thermal equilibrium, measure both end shields with a non-contact thermometer; if the difference is large and the fan side is normal, the first suspect is the load on the pulley side.
The second indicator is the vibration picture. If vibration measured radially on the shaft side is higher than on the fan side and bearing frequencies begin to appear in the spectrum, the bearing is under strain. Grease leaking from the end shield, a shiny wear mark on the belt edge and stepped wear in the pulley grooves complete the same picture.
A mistake made during fitting gives a similar result: hammering the pulley onto the shaft causes the balls to leave marks in the bearing raceway, and the motor runs noisily from day one. The pulley should be fitted by heating it or with a puller tool screwed into the centre hole at the shaft end. Other points to check at first start-up are listed in the electric motor commissioning guide.
Example electric motors that fit this calculation
Cast iron frames in the 1500 rpm class are common on belt-driven fans, compressors and crushers. Models that match the power range of the example calculation:
132M-4, 7.5 kW, 1460 rpm, 49.1 Nm; 400/690 V. The torque value in the worked example is taken from this model.
160M-4, 11 kW, 1465 rpm, 71.7 Nm. With the same pulley diameter, the radial force grows in proportion to torque, so the pulley is selected again accordingly.
180M-4, 18.5 kW, 1470 rpm, 120.2 Nm; an example of the next step up for heavy belt drives.
B3, B5, B14, B34, B35 and vertical V1/V3/V5/V6/V15 are offered depending on the frame; flange size is confirmed when ordering. The permissible radial load value, and whether a different drive-end bearing option is possible for high belt loads, are confirmed when ordering. The series is offered in IE3, IE4 and IE5 efficiency classes; the class of the model is also settled at the order stage.
If you share a photo showing the pulley diameter, belt type and number of belts, the machine speed and where the pulley sits on the shaft, together with the existing motor's nameplate, through the find an equivalent from the nameplate page, we can calculate the radial force with you and check the frame choice. Alternatives by power and speed sit side by side in the HEM Motor model list.
Frequently Asked Questions
Does a larger pulley relieve the motor bearing?
Yes. If torque stays the same and the pulley grows, the belt pull falls and so does the force carried by the shaft-side bearing. To keep the machine speed, the opposite pulley is enlarged in the same ratio.
Is it enough to set belt tension by pressing it by hand?
It is not; a setting made by hand is usually tighter than necessary. Use a deflection force table or a tension gauge that reads frequency.
Should shaft end load be considered with a coupling connection?
With a flexible coupling the radial load is small, but shaft misalignment adds load to the bearing. That is why alignment is also done by measurement on coupled drives.
The drive-end bearing is hot but the current is normal; is the problem in the motor?
Normal current suggests the mechanical load is coming from the shaft end. First check belt tension, pulley position and alignment, then inspect the bearing.
HEM Motor Models Related to This Article
The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.
In an asynchronous electric motor, slip grows roughly in proportion to load across the normal operating range: the rotor, which turns just below synchronous speed at no load, falls... More Details
An asynchronous electric motor is an AC machine whose rotor turns because the rotating field set up by the stator windings induces current in the rotor bars, so the shaft always ru... More Details
When selecting an asynchronous electric motor for a heavy inertia load, the deciding factor is not continuous running power but whether the motor can bring the load up to rated spe... More Details
The five operating mistakes that age an asynchronous electric motor early are: forcing a motor chosen for continuous duty into frequent starts, running it on unbalanced or low volt... More Details
To verify the values on an asynchronous electric motor nameplate in the field, you turn the nameplate into a measurement plan: voltage and connection type are checked in the termin... More Details
In an asynchronous electric motor, most of the no-load current is magnetising current and is almost independent of load; the part that grows as load is applied is the active compon... More Details