Why Does an Electric Motor Make a Thin Whine When Running on an Inverter?

Why Does an Electric Motor Make a Thin Whine When Running on an Inverter?

The thin, high-pitched sound heard from an electric motor running on a frequency inverter usually comes from the drive's PWM switching frequency: the output voltage is made of pulses switched on and off thousands of times a second, the current carries small ripples at that frequency and the stator lamination stack vibrates at the same frequency. The sound alone is not a fault; the easiest proof is that its tone changes when the carrier frequency changes.

Why does the same motor whistle on a drive when it is quiet on the mains?

The current of a mains-fed motor is a smooth 50 Hz sine wave; at the drive output, the current carries a jagged ripple riding at the carrier frequency. The magnetic forces in the stator follow this ripple.

The electrical steel in the lamination stack changes its dimensions very slightly under a magnetic field. This effect is called magnetostriction, and every time the field changes, the laminations lengthen and shorten on a microscopic scale. If the carrier frequency is around a few kilohertz, the vibration is at that frequency too, and the frame and fan cover pass it into the air.

The human ear is sensitive in this range. The sound feels far more annoying than the hum on the mains, although the energy it carries is small. The annoyance is real; the damage is not.

How are the sound and the motor affected when carrier frequency is changed?

Raising the carrier frequency makes the sound higher and, beyond a point, brings it close to the hearing limit of most people; lowering it makes the sound deeper and more noticeable. Both directions have a price.

At a high carrier frequency the drive's switching losses increase; many drives then reduce the continuous current they can deliver. Capacitive leakage current in a long motor cable also rises. At a low carrier frequency current ripple grows and the motor runs slightly warmer. Which value suits is read from the derating curve in the drive manual (general information; confirm with the drive manufacturer's instructions).

Trying it on site is simple. Change the carrier frequency step by step within the range the manual allows, listen at each step from the same point about a metre from the motor, and note the drive's output current and heatsink temperature. Some drives have a "random PWM" or "soft sound" setting; it spreads the single tone into a broad hiss that is less piercing to the ear.

Which sound is normal, and which points to a fault?

A high-pitched whistle that stays constant at all speeds and changes tone with the carrier frequency is normal. Sounds that rise at a particular speed, change in proportion to speed or come from a bearing housing are examined separately.

Sound heardProbable sourceCheck to make
Constant high whistle at all speeds, tone changes with carrierPWM switching, lamination stack vibrationCarrier frequency setting; sine filter if needed
Hum that rises and passes within a certain speed bandMechanical resonance in frame, base or machine structureSpeed sweep; skip frequency set in the drive
Grinding from a bearing housing, growing over timeBearing damage, wear caused by bearing currentsListening with a stethoscope, vibration measurement, bearing inspection
Deep growl and heating at low speedExcessive voltage boost or wrong V/f curveDrive parameters, current measurement at low speed
Ticking in proportion to speedLoose fan, coupling play, loose mounting boltHand check at standstill, bolt torque

If the motor has just been replaced and sounds different from the old one, that alone is not a problem, because two motors that differ in lamination quality, slot count, air gap and frame material can sound completely different on the same drive, at the same carrier frequency and under the same load. To compare alternatives of the same power and speed, frame and current values are listed on the product cards in the HEM Motor shop.

Prices and technical data are on the product pages; choose a model and order online.

In what order is the source of the sound isolated on site?

First, separate electromagnetic from mechanical; the fastest way is to cut the drive output while the motor is running and listen for whether the sound disappears at that instant.

  1. With the motor running at medium speed, give the drive a coast-to-stop command. If the whistle ends the moment power is cut and no other sound remains as the shaft slows, the source is electromagnetic.
  2. If the sound continues while coasting, it is mechanical. Listen to the two bearing ends separately, either with a mechanical stethoscope or by resting the tip of a long screwdriver on the bearing housing and its handle against your ear.
  3. Raise speed slowly from minimum to maximum and note the speeds where the sound grows. If it builds up and passes within a narrow band, look for resonance.
  4. If possible, run the motor briefly direct on line or through a bypass. If the sound disappears completely, the motor's mechanical condition is good.
  5. If the bearing side is suspect, take a reading on the bearing housing with a vibration meter and repeat it at the next service.
Foot-mounted aluminium frame three-phase electric motor
On a drive-fed motor, the source of the sound is isolated by listening at the moment of coast-to-stop (representative image).

How do the motor cable and filters affect the sound?

A sine filter brings the voltage reaching the motor closer to a sine wave and so clearly reduces the whistle at carrier frequency; a dv/dt filter mainly protects the winding insulation from voltage peaks and has a limited effect on sound.

In a long motor cable each pulse reflects at the cable end, and the voltage at the motor terminals can reach peaks higher than at the drive output. These peaks stress the inter-turn insulation of the winding, not the sound. The consequence arrives years later. Doing the insulation resistance test with the drive disconnected protects the drive from the megger voltage.

Our three-phase series are suitable for speed control with a frequency inverter; for long periods at low speed with full torque an external fan may be needed; if the drive–motor cable is long, a dv/dt or sine filter is considered; these conditions are stated with the order. If cable length, carrier frequency and drive model are written on the order, the right solution is discussed from the start.

How should a sound requirement be written into a specification?

If a sound value is required, measuring distance, load condition, type of supply and the measurement method to be applied must be written together; if one of them is missing, values taken at different sites cannot be compared.

The IEC 60034-9 family, which defines limits for motor noise, is based on sinusoidal supply (general information; confirm with the current text of the standard). Because sound character changes on a drive supply, the specification should state the drive model, carrier frequency, filter status and whether measurement is on no load or at rated load. Measuring room, microphone position and background noise correction are also part of the method.

Example steps from the 4-pole aluminium series for drive-fed applications:

  • 100L1-4: 2.2 kW, 1450 rpm, 4.52 A at 400 V, 230/400 V connection. Often seen on small fan and pump drives.
  • 112M-4: 4 kW, 1450 rpm, 7.95 A at 400 V, 400/690 V connection.
  • 132M-4: 7.5 kW, 1460 rpm, 14.3 A at 400 V, 400/690 V connection.

All are among the aluminium frame models and come with IP55 and Class F insulation. The commissioning guide lists which measurements to take at the first run after the drive is connected.

If the sound bothers you, send the drive model, carrier frequency setting, cable length and a photo of the motor nameplate through our contact page; add the result of the coast-to-stop test and we will narrow down the source together and, if needed, choose a suitable model from the product list.

Frequently Asked Questions

Does the thin sound shorten motor life?

The PWM-related high-pitched sound itself does not harm the motor. What affects life is voltage peaks on long cables and bearing currents; these are assessed separately from the sound.

Does setting the carrier frequency to maximum solve the problem?

It can reduce the sound, but the drive's continuous current capacity may drop and leakage current rises. The value is chosen from the derating curve in the drive manual.

What should be done if the sound rises only at a certain speed?

This is usually mechanical resonance. The base and mounting bolts are checked; that speed band can be set as a skip frequency in the drive.

The sound changed after the motor was replaced; is the new motor faulty?

Not necessarily. Different lamination and slot designs produce different tones at the same carrier frequency; mechanical condition is confirmed separately with the coast-to-stop test and by listening to the bearings.

HEM Motor Models Related to This Article

The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.

2.2 kW 1500 rpm Aluminium Frame Electric Motor 100L1-4

100L1-4

2.2 kW · 1500 rpm

  • Aluminium frame · IEC 100L
  • 1450 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$176.30 (€161.35)

View product
4 kW 1500 rpm Aluminium Frame Electric Motor 112M-4

112M-4

4 kW · 1500 rpm

  • Aluminium frame · IEC 112M
  • 1450 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$238.15 (€217.96)

View product
7.5 kW 1500 rpm Aluminium Frame Electric Motor 132M-4

132M-4

7.5 kW · 1500 rpm

  • Aluminium frame · IEC 132M
  • 1460 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$369.69 (€338.35)

View product

Similar Articles