Which Causes Are Investigated If an Electric Motor's Coupling Element Fails Often?

Which Causes Are Investigated If an Electric Motor's Coupling Element Fails Often?

If an electric motor's coupling element fails often, the first thing to investigate is shaft misalignment, followed by coupling selection, starting and shock loads, environmental effects such as heat and oil, and whether the motor or machine has shifted. The rubber element is usually not the problem itself but the first part to report another fault; simply renewing the element postpones the failure by a few weeks.

What does the coupling element do in a drive?

In a flexible coupling, the rubber or polyurethane element transmits the torque from the motor shaft to the machine shaft while damping small alignment differences and shocks. This flexing part absorbs faults between the two shafts up to a point. Beyond that point the load is still carried by the element. Flexing and recovering on every turn, it heats up, hardens, cracks and finally breaks apart. The life of the element therefore reveals how well the drive has been set up.

What does the appearance of a failed element tell you?

The surface of the removed element gives the first clue to where the fault comes from. Photographing the element before throwing it away and laying the pieces side by side makes diagnosis easier.

AppearanceLikely sourceWhere to look first
Heavy wear on one side, black dust aroundAngular or parallel misalignmentAlignment measurement
Cuts and breaks in the teethShock load, frequent starts, excessive torqueNumber of starts and load type
Surface hardening and fine cracksExcessive heat or ageingTemperature around the coupling
Swelling, softening, stickinessContact with oil, fuel or chemicalsSource of the leak
Element displaced, hubs touchingWrong axial gap or shaft movingDistance between hubs

The matches in the table are not definitive; more than one cause may be present at the same time (general information; confirm with the coupling manufacturer's technical documentation).

Why is shaft misalignment checked first?

On site, the most common source of coupling element failures is the motor shaft and machine shaft not lying on the same axis. Misalignment appears in two forms. In parallel misalignment the axes are parallel but offset; in angular misalignment one is tilted relative to the other.

Alignment by eye or with a straightedge often cannot meet the limits given by coupling manufacturers. Measurement is taken with a dial indicator or a laser alignment tool; values are corrected with shims under the motor feet and horizontal shifting.

Alignment is done on a cold machine, but the machine warms up when running. If a pump casing expands with hot liquid or the motor and machine reach different temperatures, the axes shift again in hot running. In this case a deliberate offset is given to the cold alignment; its value is obtained from the machine manufacturer.

A gap under a foot also spoils alignment.

If one of the feet does not sit on the base, the housing is strained when the bolt is tightened and the shaft axis moves. On site this is called soft foot. It is found by loosening each foot in turn and watching shaft movement with a dial indicator, and corrected with shims.

Could the coupling selection be wrong?

It could. A coupling is selected by applying a service factor to the motor's rated torque; the factor varies with the load type. A smoothly running centrifugal pump and a crusher with shock loads cannot use the same coupling.

The motor's rated torque is found from nameplate power and speed: T = 9550 × P / n. Here T is in newton-metres, P in kilowatts and n the speed per minute. For a 2-pole 11 kW motor this value is about 35.7 Nm. The torque value in the coupling catalogue must be greater than this number multiplied by the factor for the load type.

Speed is also a limit, and it should not be skipped. Each coupling size has a maximum permitted speed, and 2-pole motors can approach this limit. The shaft diameter must also fit within the bore range of the coupling hub; motors can be viewed side by side by power and speed step on the shop page.

Prices and technical data are on the product pages; choose a model and order online.

How do starting, stopping and shock loads affect the element?

A motor started direct-on-line can deliver several times its rated torque for a short time at the moment of starting. This peak passes through the element at every start. In a drive starting many times an hour, the element is fatigued by these peaks more than by continuous running.

The ways to limit starting torque are star-delta connection, a soft starter and a frequency inverter. Our three-phase series are suitable for speed control with a frequency inverter; long operation at low speed with full torque may require a separate fan; if the drive-to-motor cable is long, a dv/dt or sine filter is considered; these conditions are stated with the order.

Sudden reverse stopping, backflow caused by a check valve closing on a pump line and the machine jamming also reach the element as shocks.

Keyed shaft end of a three-phase electric motor
The coupling hub is fixed to the shaft end with a key; shaft end size and key seating are checked when selecting the coupling (representative image).

What are the environmental conditions and installation errors?

Rubber and polyurethane elements have an operating temperature range. A coupling that heats up near a furnace, on a pump delivering hot liquid or inside an enclosed guard causes the element to harden sooner than expected. Oil leakage is another enemy. Oil leaking from a gearbox or pump seal swells and softens some elastomers. Renewing the element without fixing the leak changes nothing; if necessary, an element of oil-resistant material is chosen.

If the axial distance between the hubs is not set to the catalogue during installation, the element either gets squeezed or runs loose. A hub loosening on the shaft, key play and a forgotten set screw also make the element run with shocks.

What is checked on the motor side?

The motor shaft itself is on the checklist too. If the shaft end has runout, meaning its tip draws a circle while turning, it crushes the element at the same point on every turn. Runout is measured at the shaft end with a dial indicator. A motor with increased bearing clearance allows the shaft to move under load. If the foot bolts are loose or the base is cracked, alignment breaks down by itself during operation. Vibration measurement helps tell these faults apart.

The motor's nameplate, shaft end size and speed are also needed to choose a new coupling during replacement.

Which HEM Motor motors can be considered for a direct-coupled drive?

Three two-pole cast iron housing options preferred in drives coupled directly, such as pumps and fans: 160M1-2 (11 kW; rated torque 35.7 Nm; rated current 19.6 A at 400 V; 2945 rpm), 160L-2 (18.5 kW; 60.1 Nm; 32.5 A; 2940 rpm) and 180M-2 (22 kW; 71.1 Nm; 38.5 A; 2955 rpm). These models are 400/690 V, IP55 with class F insulation; for shaft end dimensions see the 2D technical drawings.

The family's other frames are on the cast iron electric motors page. B3, B5, B14, B34, B35 and vertical V1/V3/V5/V6/V15 are offered according to frame; the flange size is confirmed with the order.

If you send a photo of the failed element, the coupling type, the motor nameplate and the load type through our contact page, we will review the possible causes on the motor side together. For current prices, the HEM Motor product list can be opened.

Frequently Asked Questions

How often should a coupling element be replaced?

There is no fixed interval; in a correctly aligned and correctly selected coupling the element lasts a long time. If the element fails at short intervals, this is a fault symptom, not a replacement schedule.

Does fitting a harder element solve the problem?

A hard element absorbs less misalignment and passes the load to the bearings. If a hard element is fitted without correcting misalignment, the bearing may fail instead of the element.

When should alignment be checked again?

It is checked when the motor or machine has been removed, when work has been done on the base and when the machine has warmed up after the first start. The measurement is also repeated in periodic maintenance.

Does the element give warning before it fails?

Black dust collecting around the coupling, a change in sound and rising vibration are early signs. Looking at the element surface when the coupling guard is opened also gives an idea of its condition.

HEM Motor Models Related to This Article

The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.

11 kW 3000 rpm Cast Iron Frame Electric Motor 160M1-2

160M1-2

11 kW · 3000 rpm

  • Cast iron frame · IEC 160M
  • 2945 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$517.78 (€473.89)

View product
18.5 kW 3000 rpm Cast Iron Frame Electric Motor 160L-2

160L-2

18.5 kW · 3000 rpm

  • Cast iron frame · IEC 160L
  • 2940 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$700.26 (€640.89)

View product
22 kW 3000 rpm Cast Iron Frame Electric Motor 180M-2

180M-2

22 kW · 3000 rpm

  • Cast iron frame · IEC 180M
  • 2955 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$841.02 (€769.72)

View product

Similar Articles