Electric Motor Rotor Balancing: Single-Plane vs Two-Plane Balancing

Electric Motor Rotor Balancing: Single-Plane vs Two-Plane Balancing

Electric motor rotor balancing is the process of reducing the centrifugal force caused by uneven mass distribution around the shaft to an acceptable limit. Single-plane balancing corrects the unbalance in one section of the rotor and removes only static unbalance; two-plane balancing corrects in two separate sections and removes static and couple (moment) unbalance together. Which method is sufficient depends on the rotor's length-to-diameter ratio, the speed and the phase relationship seen in the vibration measurement. Below we explain the types of unbalance, the permissible residual unbalance calculation and which balancing to choose in which situation in the field.

Why does unbalance produce vibration?

If the rotor's centre of mass is offset from the axis of rotation by e, this rotating mass produces a force that changes direction once per revolution: F = m × e × ω². Because the force grows with the square of angular speed, the same offset produces four times the force at 3000 rpm compared with 1500 rpm. Speed multiplies the effect of unbalance. Consequently, on two-pole, i.e. fast-running machines, how well the rotor is balanced affects the vibration level far more noticeably than on four- or six-pole ones.

The vibration signature of unbalance is typical: the dominant component in the spectrum is at 1× running frequency (a 2-pole motor on a 50 Hz supply turns at about 49 Hz), it is pronounced in the radial direction and the amplitude hardly changes with load. Dominant vibration in the axial direction points rather to other causes such as misalignment or a bent shaft. This distinction matters in diagnosis.

What types of unbalance are there?

Unbalance appears in three forms depending on the position of the centre of mass and the principal axis of inertia relative to the axis of rotation:

  • Static unbalance: The principal axis is parallel to the axis of rotation but displaced. When the rotor is placed on two knife-edge rails, the heavy side turns downwards. Vibration at both bearings is in phase.
  • Couple (moment) unbalance: The centre of mass lies on the axis but the principal axis crosses the axis of rotation at the centre; the rotor behaves as if there were equal weights in opposite directions at its two ends. It cannot be noticed at standstill and only appears when rotating. Vibration at the two bearings is about 180° out of phase.
  • Dynamic unbalance: The general case where static and couple unbalance occur together; the vast majority of real rotors are in this class. The phase difference between bearings can take any value between 0° and 180°.

Single-plane correction can only eliminate the static component. Because the couple component is a moment, it can only be balanced by placing weights in opposite directions in two planes far apart along the axis.

Should you choose single-plane or two-plane balancing?

In practice the choice rests on three pieces of information: the rotor's length-to-diameter ratio, the operating speed and the measured phase relationship. The table below summarises the general trend; for a firm decision the rotor geometry and vibration data are assessed together.

SituationUsually sufficientReason
Disc-shaped part (fan impeller, pulley, thin wheel), length-to-diameter ratio below about 0.5Single-planeMass is concentrated along a short axis, so the couple component stays small
Long cylindrical rotor (motor rotor, long drum), length similar to or greater than diameterTwo-planeMass is spread along the axis; couple unbalance is significant
Low speed (below about 1000 rpm), short rotorOften single-planeCentrifugal force is small, moment effect limited
High speed (2-pole, around 3000 rpm)Two-planeForce grows with the square of speed; even a small couple unbalance loads the bearings
Vibration at the bearings in phaseSingle-plane can be triedStatic component dominant
Clear phase difference between bearings (over 90°)Two-planeCouple component present

Because the length of an electric motor rotor is usually close to or greater than its diameter, it is balanced in two planes during manufacture; correction is usually made by removing material from, or adding weight to, the short-circuit rings at the two ends of the rotor core. A thin pulley or fan wheel fitted to the shaft afterwards can, in most cases, be balanced in a single plane.

Shaft end and keyway of a three-phase electric motor
The pulley or coupling fitted to the shaft forms a balanced system together with the rotor (illustrative image).

How is permissible residual unbalance calculated?

Permissible residual unbalance is calculated from the balance quality grade G, the rotor mass and the operating speed. No rotor can be made with zero unbalance; the aim is to bring the remaining (residual) unbalance below an acceptable limit. ISO 21940-11 (formerly ISO 1940-1) defines this limit with the balance quality grade G. The grade gives the product of the centre-of-mass offset and angular speed in mm/s; the common grade for electric motors is G 2.5, and G 1 may be requested for more sensitive applications (general knowledge; refer to the relevant standard for details and the grade table).

The total permissible residual unbalance is found as follows: Uper [g·mm] ≈ 9549 × G × m / n. Here G is the balance grade in mm/s, m the rotor mass in kilograms and n the operating speed in rpm.

A hypothetical example: a rotor with a mass of 30 kilograms is to be balanced to grade G 2.5 at 3000 rpm. Uper ≈ 9549 × 2.5 × 30 / 3000 ≈ 239 g·mm. On a symmetrical rotor this value is shared roughly equally between the two planes; about 120 g·mm per plane. With a correction radius of 60 mm, the maximum unbalance that may remain in each plane corresponds to an equivalent mass of 120 / 60 ≈ 2 grams. If the same rotor ran at 1500 rpm the permissible value would double; this shows why balancing must be more precise on high-speed motors.

Prices and technical data are on the product pages; choose a model and order online.

What is the half-key rule, and how are motor and pulley matched?

The half-key rule means a keyed-shaft motor is balanced with a key filling the keyway to half depth. The pulley should be balanced the same way. When the rotor of a motor with a keyed shaft is balanced, the empty keyway is also a source of unbalance. In international practice electric motors are generally balanced with a "half key": a key filling the keyway to half depth is fitted (ISO 21940-32 describes the key convention; IEC 60034-14 takes half-key balancing as the basis for motors). Motors balanced with a half key may carry an "H" mark on the shaft end or nameplate; those balanced with a full key are marked "F".

A common mistake in the field is fitting a pulley balanced with a full key to a motor balanced with a half key. The key allowance is counted twice or not at all, and the system vibrates even though both parts are well balanced individually. Balancing the pulley with the half-key method too, or shortening the part of the key projecting beyond the pulley length, prevents this problem.

How is field balancing done?

If the motor is to be balanced in place together with the driven machine, the influence coefficient method is used with a portable vibration analyser and a phase reference (optical tachometer). The general sequence is:

  1. Initial measurement: The 1× vibration amplitude and phase at both bearings are recorded at operating speed.
  2. Trial weight: A trial weight of known mass and angle is fitted in the first plane and the measurement is repeated. After the trial weight is removed, the same is done for the second plane.
  3. Influence coefficients: The change in amplitude and phase at both bearings caused by each trial weight gives one influence coefficient per plane.
  4. Correction: The analyser solves the two-unknown equation system and calculates the correction mass and angle for each plane.
  5. Verification: After fitting the correction weights a final measurement is made; fine adjustment is repeated if needed.

In single-plane field balancing the same procedure is done with one trial weight. However, balancing done without eliminating causes other than unbalance (soft foot, misalignment, bearing damage) gives no lasting result. These causes must be ruled out first.

How is a motor selected for applications with high balancing demands?

When a fan impeller, centrifugal pump or screw compressor is coupled directly to the motor, the motor's balance quality forms the basis of system vibration. For such jobs you can compare different power and speed alternatives in the electric motor shop. When choosing couplings and pulleys to suit motor dimensions, the shaft diameter and length values in the IEC frame size table are useful. The common features of the series are summarised on the general-purpose industrial motors page. Example models:

  • 160M1-2: 11 kW, 2945 rpm, aluminium frame; common in fan and pump applications and, because of the high speed, a class sensitive to balance quality.
  • 200L2-2: 37 kW, 2960 rpm, cast iron frame; a power range used in directly coupled centrifugal pumps and blowers.
  • 280M-2: 90 kW, 2975 rpm; at this size rotor mass is high, and two-plane balancing and bearing vibration monitoring become important.

All options are listed on the purchase page. If the motor will run at different speeds with a frequency inverter, check during commissioning with a vibration measurement whether any speed in the range coincides with a resonance.

If you have a motor with high vibration, send us the nameplate data and the bearing vibration values you measured (amplitude and phase if possible) via the nameplate submission page; together we will assess whether balancing, alignment or a motor replacement is needed.

Frequently Asked Questions

What happens if a motor rotor is balanced in a single plane?

The static component is removed but the couple unbalance remains. The rotor may look balanced when turned slowly; at operating speed, however, anti-phase vibration continues at the two bearings.

Vibration increased after the pulley was changed; is the motor faulty?

First check the pulley balance and the key arrangement. Fitting a full-key-balanced pulley to a half-key-balanced motor, or a projecting key length, increases 1× vibration even when the motor is sound.

Is the difference between G 2.5 and G 1 noticeable in the field?

It can be on high-speed and precision machines. G 1 reduces the permissible residual unbalance by about 2.5 times compared with G 2.5; but if installation, coupling and foundation quality are poor, the benefit of this difference may not show in the vibration.

Does the motor have to be dismantled for balancing?

Removal depends on the rotor's condition. Field balancing can be done with the motor in place, together with the driven machine. If the rotor itself has serious unbalance or the correction planes are not accessible, balancing on a balancing machine in a workshop is required.

HEM Motor Models Related to This Article

The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.

11 kW 3000 rpm Aluminium Frame Electric Motor 160M1-2

160M1-2

11 kW · 3000 rpm

  • Aluminium frame · IEC 160M
  • 2945 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$494.25 (€452.35)

View product
37 kW 3000 rpm Cast Iron Frame Electric Motor 200L2-2

200L2-2

37 kW · 3000 rpm

  • Cast iron frame · IEC 200L
  • 2960 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$1,455.48 (€1,332.09)

View product
90 kW 3000 rpm Cast Iron Frame Electric Motor 280M-2

280M-2

90 kW · 3000 rpm

  • Cast iron frame · IEC 280M
  • 2975 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$3,264.82 (€2,988.03)

View product

Similar Articles