The quickest way to tell an open circuit from overtemperature in an electric motor's PTC circuit is to measure the resistance of the PTC leads while the motor is cold: if the cold winding reads somewhere around a few hundred ohms, the sensor is healthy and the earlier trip came from real heating; if the multimeter shows infinity (OL), the circuit is broken. The distinction is confirmed by watching how resistance behaves as the motor cools.
How does a PTC sensor report temperature?
A PTC thermistor shows a low, almost constant resistance up to a certain threshold temperature; near the threshold its resistance rises steeply within a few degrees. Three sensors embedded in the winding are connected in series and their two ends come out to a separate terminal in the terminal box.
The motor itself does not interpret this resistance. The leads go to the thermistor relay in the panel; the relay sends a small measuring current, opens its contact when resistance passes the threshold and drops out the main contactor. For the relay both situations are the same: whether the winding overheats or the cable breaks, what it sees is high resistance. That is why the technician has to make the distinction.
The sensor's threshold temperature is chosen according to the insulation class and is written in the motor's winding data. At HEM Motor, PTC and PT100 winding sensors are an order option; which threshold temperature is applied is confirmed with the order.
What does a resistance measurement on a cold motor show?
When the motor has stood for at least a few hours and cooled to ambient temperature, the total resistance of the three series PTCs should be low; typically each sensor reads between tens and a few hundred ohms (general information; confirm with the sensor and relay manufacturer's data sheet). If this value is seen, the sensor chain is intact.
The measuring order should be as follows:
- Isolate and lock off the supply, and also disconnect the thermistor relay's supply voltage.
- Remove the PTC leads at the relay end; measure first in the panel, including the cable.
- Set the multimeter to a low ohms range and read between the two ends.
- If the value is infinite, open the motor terminal box and repeat the same measurement directly on the PTC terminals.
A panel reading of infinity together with low resistance at the motor puts the break in the cable.
When the motor also reads infinity, the sensor chain has opened inside the winding.
Never connect an insulation tester (megger) to the PTC leads. The high test voltage destroys the thermistor within a second, makes a healthy sensor read open at the next measurement and also hides the original fault. The measuring instrument's test voltage must be low; many manufacturers limit it to a few volts.
How are an open circuit and real heating told apart on site?
With an open circuit the relay stays open even when the motor is cold and will not reset; with real heating, resistance falls as the motor cools and the relay can reset automatically or by hand. Time is the most reliable witness for this distinction.
| Observation | Open circuit | Overtemperature |
|---|---|---|
| When did the relay open? | At start-up or at a moment of vibration, motor cold | After running under load for a while |
| Frame temperature | Close to ambient | So hot a hand cannot stay on it even for a few seconds |
| Cold resistance reading | Infinite or unstable | Low, normal value |
| As the motor cools | No change, relay does not reset | Resistance falls, relay resets |
| When the cable is moved slightly | Value jumps (loose end) | Value does not change |
An unstable reading is especially important. If the value on the multimeter display jumps between infinity and low when the cable or terminal screw is touched, the problem is a loose connection or a broken conductor. Vibration from the fan end exposes this kind of break during running, the contact closes again when the motor stops, and the fault looks as if it "cleared itself".
If overtemperature is confirmed, where is the cause looked for?
When the PTC really reported heating, the sensor has worked correctly and the problem lies in the motor's cooling or load balance. The checks fall under four headings: current, voltage, cooling air and duty pattern.
The clamp meter is placed on the three phases in turn and the readings are compared with the plate value; line-to-line voltage is measured at the same time, because low voltage and phase imbalance raise current. Then the fan cover is inspected from outside without removing it. If dust, fibre or oily dirt has built up on the cover grille and the gaps between the frame fins are packed, the motor cannot draw its own air.
In textile and flour mills, a grille that clogs within a few weeks is the most frequent cause of PTC trips.
The same result is seen on motors driven at low frequency by a converter for many hours, because the shaft-mounted fan slows down and airflow drops. Our three-phase ranges are suitable for speed control with a frequency converter; for long periods at low speed with full torque an external fan may be needed; if the drive-to-motor cable is long, a dv/dt or sine filter is considered; these conditions are stated with the order.
Frequent stop-start is another overlooked cause. Every start heats the winding with a current several times rated current; if the permitted number of starts per hour is exceeded, the winding heats up even when average current looks normal. A conveyor on a packaging line that stops for every product, or a pump that switches on and off according to temperature, can make hundreds of starts a day, and at the end of the shift its frame is noticeably hotter than a motor of the same power running continuously; in that case blaming the sensor without comparing the number of starts with the machine manufacturer's data is a mistake. Models for similar duties are listed by power and frame in the store.