Telling Electrical Hum from Mechanical Noise in an Electric Motor

Telling Electrical Hum from Mechanical Noise in an Electric Motor

The quickest way to separate the source of a noise from an electric motor is to cut the power and listen: if the sound disappears the moment the switch opens, it originates in the magnetic field; if it continues while the motor coasts down and fades with speed, it is mechanical. Electrical hum is usually a steady buzz at twice the supply frequency, around 100 Hz on a 50 Hz network; mechanical noise comes from the bearings, cooling fan, coupling, belt or a loosened part, and its tone changes with speed. Replacing bearings or blaming the winding without making this distinction is often a wasted intervention.

Where do hum and mechanical noise physically come from?

When alternating current flows through the stator winding, the lamination stack is magnetised and released every half cycle. Because the magnetic force depends on the magnitude of the flux rather than its sign, the stack vibrates at twice the supply frequency; magnetostriction, which changes the length of the laminations very slightly, adds to the same frequency. That is why the fundamental tone of electrical hum is around 100 Hz on a 50 Hz supply.

Mechanical noise, by contrast, comes from defects in rotating parts. An unbalanced rotor or pulley makes noise at rotational frequency, a damaged bearing at characteristic frequencies derived from ball and ring geometry, and fan blades at the number of blades multiplied by rotational frequency. All of these frequencies are proportional to speed; as the motor slows down, they all shift downwards together.

Hypothetical calculation: which frequency points to what in a 4-pole motor?

Hypothetical example: a four-pole motor on a 50 Hz supply runs at 1450 rpm under load.

  1. Rotational frequency: fr = 1450 / 60 ≈ 24.2 Hz. Unbalance and misalignment appear at this frequency and its multiples.
  2. Electrical hum: 2 × 50 = 100 Hz. It is independent of speed; while power is applied it stays the same even if the motor slows.
  3. Slip: s = (1500 − 1450) / 1500 ≈ 0.033; slip frequency s × 50 ≈ 1.67 Hz.
  4. Pole pass frequency: 4 × 1.67 ≈ 6.7 Hz. A broken rotor bar makes the hum pulsate at this rate; the ear hears a "wow-wow" rising and falling six or seven times a second.

This simple calculation is enough to tell which peak belongs to what in a spectrum taken with a phone app or a handheld vibration meter. For exact bearing frequencies, use the geometry data supplied by the bearing manufacturer (general information; confirm with the bearing manufacturer's calculation).

Separation tests applied in the field

Even without measuring instruments, the source can be narrowed down considerably. The following tests are applied in order:

  1. Cut the power. With the motor at full speed, the switch is opened. A sound that stops with the switch is magnetic in origin. If it continues through the coast-down and its pitch falls, the source is mechanical.
  2. Separate the load. The coupling or belt is removed and the motor run unloaded. If the motor runs quietly unloaded, look for the problem in the driven machine or the connecting element.
  3. The current of the three lines is read with a clamp meter and the line voltages with a multimeter. A clear current difference, a missing phase or unbalanced voltage roughens the hum and heats the motor.
  4. After the motor is locked out and tagged, the shaft is turned by hand. Rough rotation, sticking or axial play points to a mechanical source.
  5. A long screwdriver or mechanical stethoscope is touched in turn to the end shield, the middle of the frame and the fan cover. The point where the sound is strongest locates the source.

A motor that hums loudly at start-up and does not turn, or starts very slowly, has usually lost one of its phases. Starting it again and again will burn the winding quickly; first check the fuses, contactor contacts and terminal connections.

Prices and technical data are on the product pages; choose a model and order online.

Likely cause and first check by type of sound

Turning the description of a noise into a common language on site speeds up diagnosis. When writing down the symptom, always note what the sound does when power is cut, whether it changes with load and where it is heard most strongly. If you decide to renew the motor, models of different kW ratings and pole numbers can be viewed side by side in our electric motor shop.

Description of soundWhen switched offProbable sourceWhere to look first
Steady, deep buzzStops instantlyNormal magnetic hum or supply above nameplateLine voltage, star-delta connection
Harsh, trembling hum, motor heatingStops instantlyMissing phase, unbalanced voltagePhase currents, fuses and contactor
Pulsating "wow-wow" soundStops instantlyRotor bar defectCurrent pulsation and pole pass frequency
Thin, high-pitched whistleStops instantlySwitching noise of the frequency inverterCarrier frequency setting
Grinding, rumbling soundContinues while slowingBearing damage or dried-out greaseBearing temperature and vibration
Rhythmic knockingBecomes slower while coastingUnbalance, loose pulley or couplingKey, pulley and foot bolts
Rustling, wind noiseFades while slowingFan touching the coverFan cover and blade condition

The power-cut column of the table is the most reliable discriminator. However, a loose lamination stack or foot bolt can amplify magnetic vibration and spread the sound through the frame; in that case the source is electrical and the amplifying factor mechanical.

Foot-mounted three-phase electric motor with aluminium frame
The source of the sound is localised by touching the listening rod in turn to the front end shield, the middle of the frame and the fan cover (representative image).

Why does the sound change in inverter-driven systems?

Motors fed by an inverter produce two additional sounds. The first is a thin whistle from the switching frequency; a carrier frequency of a few kHz creates an audible tone in the winding and the lamination stack. Raising the carrier frequency reduces the noise but increases inverter losses; adjust it within the limits set by the inverter manufacturer.

The second is a resonance noise that rises at certain speeds. Vibration grows at a speed that coincides with the natural frequency of the motor or its base; this speed band can be skipped with the inverter's skip frequency parameter. If a rhythmic sound starts coming from the bearing of an inverter-driven motor, the possibility of bearing currents should also be investigated.

After diagnosis: repair or replacement?

Most electrically caused hum is solved outside the motor: a loose terminal is tightened, a missing phase is restored, voltage balance is corrected. For mechanical sources, replacing a bearing, fan or coupling is usually enough. A rotor bar defect, a loosened lamination stack or a housing that has eaten bearings repeatedly, however, brings repair cost close to that of a new motor. The checks before restarting are given step by step in the first start-up checklist.

Examples from our aluminium frame electric motors where replacement is needed (pairings are hypothetical):

  • For a small fan or mixer, the 1.1 kW, 4-pole 90S-4: 1445 rpm, 7.27 Nm.
  • For a lightly loaded belt conveyor or centrifugal pump, the 3 kW 100L2-4: 1450 rpm, 19.8 Nm.
  • For a medium-power extractor or compressor, the 7.5 kW 132M-4: 1460 rpm, 49.1 Nm.

If you share a recording of the sound, a photo of the motor nameplate and the phase currents you measured through the nameplate submission page, we will assess the source together and, if necessary, identify a suitable equivalent. The information requested at quotation stage is summarised in the article information to provide when requesting a quote; all options by frame and power are in the HEM Motor product list.

Frequently Asked Questions

Is a slight hum from a running motor normal?

Yes. A steady, low-level hum caused by magnetic vibration of the lamination stack is normal. If the sound becomes harsh, pulsates or the motor heats up, a check is needed.

What does it mean if the hum increases with load?

Hum that grows with load is related to current; investigate unbalanced voltage, a missing phase or a rotor bar defect. Measuring the phase currents is the first step.

Can bearing noise and magnetic noise be told apart with a phone?

An app that shows a spectrum gives a rough idea. A steady peak around 100 Hz points to a magnetic source, peaks that shift with speed to a mechanical one.

What should be done if the motor hums at start-up but does not turn?

Stop the motor immediately. The most common cause is a missing phase; do not restart it before checking the fuses, contactor and terminal connections.

HEM Motor Models Related to This Article

The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.

1.1 kW 1500 rpm Aluminium Frame Electric Motor 90S-4

90S-4

1.1 kW · 1500 rpm

  • Aluminium frame · IEC 90S
  • 1445 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$116.16 (€106.32)

View product
3 kW 1500 rpm Aluminium Frame Electric Motor 100L2-4

100L2-4

3 kW · 1500 rpm

  • Aluminium frame · IEC 100L
  • 1450 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$190.83 (€174.65)

View product
7.5 kW 1500 rpm Aluminium Frame Electric Motor 132M-4

132M-4

7.5 kW · 1500 rpm

  • Aluminium frame · IEC 132M
  • 1460 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$369.69 (€338.35)

View product

Similar Articles