Detecting Turn-to-Turn Shorts in an Electric Motor with a Surge (Impulse) Test

Detecting Turn-to-Turn Shorts in an Electric Motor with a Surge (Impulse) Test

The surge (impulse) test applies short, high-voltage, very fast-rising pulses to an electric motor winding and compares the damped oscillation wave the winding returns in order to detect turn-to-turn short circuits. Insulation resistance and winding resistance measurements often cannot see this kind of fault, because the insulation between turns looks sound at low voltage but breaks down during mains switching or inverter pulses. The surge test catches this weak point before the motor starts running and before the fault turns into a phase-to-phase or phase-to-earth short circuit.

Why is turn-to-turn insulation the first weak link?

Between neighbouring wires in a coil there is only the enamel layer and the varnish. In normal 50 Hz operation the voltage between two adjacent turns is small. But during starting, contactor switching or the fast switching of a frequency inverter, the voltage is not distributed evenly across the coil but piles up on its first turns. A small scratch in the enamel, a wire crushed during winding or varnish that has absorbed moisture breaks down under this build-up.

The breakdown point first short-circuits a few turns. By transformer action a large current circulates in the shorted turns, the area heats rapidly and burns the surrounding insulation. The result is usually a phase-to-earth or phase-to-phase fault within a few hours or days. That is why early detection is cheap and late detection costs the entire winding.

What does the impulse wave tell you about the winding?

The tester charges a capacitor to a high voltage and discharges it rapidly through the winding under test. The capacitor and the winding inductance form an LC circuit and a damped sine wave appears on the screen. The oscillation frequency is given approximately by f = 1 / (2π · √(L · C)), where L is the winding inductance and C the tester's capacitor.

If there is a short between turns, the shorted turns reduce the effective inductance of the winding and increase losses. This has two visible consequences. The wave frequency rises, so the wave shifts to the left. Damping also speeds up, and the wave amplitude shrinks faster. In a sound winding, the waves of the three phases of the same motor lie almost exactly on top of each other.

A hypothetical frequency shift example

Let the sound phase oscillate at around 10 kHz. When a few turns are shorted in one phase, the effective inductance drops by a few per cent; because of the square-root relationship the frequency rises by less than that, but clearly enough to be visible on the screen. For example, if inductance drops by about 4%, frequency rises by about 2% and the wave shifts a few hundred hertz to the left. These ratios are general knowledge; follow the test equipment manufacturer's instructions for interpretation.

How is the test voltage selected?

The impulse voltage must be high enough to represent the worst voltage stress the winding will face in service, and limited enough not to overstress sound insulation. In practice the test voltage is set according to the motor's rated voltage and whether the winding is new or used; a higher value is chosen for a new winding and a lower one for an old winding from the field. For the numerical value, follow the test equipment manufacturer's table and the workshop's written procedure.

The rise time of the pulse also matters. A very fast voltage rise concentrates the stress on the first turns of the coil and creates a situation similar to inverter pulses in the field. The voltage is increased in steps and the wave is recorded at each step. If a fault suddenly appears at a certain voltage, that voltage shows the real withstand limit of the insulation.

Three-phase electric motor being prepared for a winding test on a workshop bench
The surge test is usually carried out from the terminal box, with the motor on the bench or installed and the cable connection removed (representative image).

How is the impulse test applied step by step?

  1. Disconnect the motor completely from the mains and the drive, and remove the links and supply cables in the terminal box.
  2. First measure insulation resistance; if phase-to-earth insulation is weak, do not proceed to the impulse test.
  3. Measure the winding resistance of all three phases; note any marked imbalance, as it will be interpreted together with the surge result.
  4. Connect the tester between the first phase and the others and increase the voltage in steps, starting low.
  5. Record the wave of each phase at the same voltage and overlay them on the screen for comparison.
  6. If a difference appears, repeat the measurement; if the shift remains, write the faulty phase and the voltage value in the report.

On installed motors the rotor position can slightly affect the wave; in a doubtful case, turning the shaft a little and repeating the measurement separates a rotor-related difference from a turn fault. In measurements made through a long supply cable, cable capacitance changes the wave, so where possible the test should be done directly at the terminals.

Prices and technical data are on the product pages; choose a model and order online.

How is the wave comparison interpreted?

Appearance on screenPossible meaningAction
Three phase waves overlapTurn-to-turn insulation soundRecord it, put the motor into service
One phase shifted left, fast dampingTurn-to-turn short circuitWinding repair or motor replacement
Sudden jump at a certain voltage, sparkingInsulation breakdown at that voltageStop the test, plan to strip the winding
Slight, constant difference between phasesCoil connection layout or rotor positionTurn the shaft and measure again
Change in the same direction on all phasesTest lead or connection problemCheck the connections

What are the limits of the test, and does it harm the winding?

The surge test reveals turn-to-turn and phase-to-phase weakness, but it does not show the moisture condition of slot insulation or bearing problems. A test at the appropriate voltage does not wear sound insulation; it may, however, turn a borderline weak point into a permanent fault.

That is the purpose of the test: the weak point shows up in the workshop, not in production.

For small and medium power motors with a turn-to-turn short, the choice between rewinding and a new motor comes down to time and cost. You can browse new motor options by power and speed in our electric motor shop.

Our three-phase series are suitable for speed control with a frequency inverter; for long periods at low speed with full torque an external fan may be required; if the drive-to-motor cable is long, a dv/dt or sine filter is considered; these conditions are stated when ordering.

Which models can replace a motor whose winding failed the impulse test?

The pairings below are hypothetical; they must be compared with the existing motor's nameplate and connection dimensions.

  • For a 2.2 kW inverter-driven conveyor, the 4-pole aluminium-frame 100L1-4; 1450 rpm, 230/400 V.
  • For a 4 kW pump with frequent starts, the cast iron 112M-4; rated current 7.95 A.
  • For an 11 kW fan drive, the aluminium-frame 160M-4; 1465 rpm, 400/690 V.

The features of the general series these models belong to can be found on the general-purpose industrial motors page.

How do you decide after the impulse test?

The test report should include the voltage value, the faulty phase, screenshots of the waves and the insulation resistance result together; this document also becomes the reference for later measurements. If you are considering a new motor to replace the faulty one, send the wave screenshot from the report and a photo of the motor nameplate via the find an equivalent from the nameplate page; add the drive and cable conditions and we will settle on the right model together. Other power options are listed on the HEM Motor product page.

Frequently Asked Questions

Why carry out a surge test on a motor that passed the insulation resistance test?

The insulation resistance test measures insulation between phase and frame; it does not see the insulation between adjacent turns of the same coil. Turn-to-turn weakness only shows up under impulse voltage.

Does a surge test damage a sound winding?

A test at a voltage in line with the manufacturer's procedure does not wear a sound winding. It may, however, break through a point that is already borderline and make it visible.

Can the test be done with the rotor in place?

Yes, but the rotor position can change the wave slightly. If a difference looks suspicious, turning the shaft and repeating the test clarifies the result.

Are turn-to-turn faults more common in inverter-driven motors?

The risk increases because fast-rising pulses and reflections in long cables put more voltage on the first turns. On long cables a dv/dt or sine filter reduces this stress.

HEM Motor Models Related to This Article

The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.

2.2 kW 1500 rpm Aluminium Frame Electric Motor 100L1-4

100L1-4

2.2 kW · 1500 rpm

  • Aluminium frame · IEC 100L
  • 1450 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$176.30 (€161.35)

View product
4 kW 1500 rpm Cast Iron Frame Electric Motor 112M-4

112M-4

4 kW · 1500 rpm

  • Cast iron frame · IEC 112M
  • 1450 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$249.49 (€228.34)

View product
11 kW 1500 rpm Aluminium Frame Electric Motor 160M-4

160M-4

11 kW · 1500 rpm

  • Aluminium frame · IEC 160M
  • 1465 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$532.46 (€487.32)

View product

Similar Articles