There are two classic electrical ways to stop an electric motor quickly: in plugging (reverse-current braking) two supply leads of the running motor are swapped so that the rotating field reverses, while in DC braking the motor is disconnected from the mains and direct current is fed into the stator winding to set up a stationary magnetic field. The first is very fast but puts a heavy load on the rotor and the supply; the second is gentler, generates less heat and carries no risk of the motor starting in the opposite direction once it stops. Which one to choose depends on the inertia of the mass being stopped, the target stopping time, the number of braking cycles per hour and how the control circuit is built.
What happens when the rotating field is reversed in plugging?
The field reverses and the motor slows down hard. In an induction motor the rotor turns slightly below the synchronous speed of the stator field; slip is found with the formula s = (ns − n) / ns. When two phases are swapped at full speed, the field turns the other way and the rotor slips backwards relative to the field at roughly twice the speed, so slip at the start of braking is close to 2. At this moment the voltage and frequency induced in the rotor bars are even higher than at starting.
As a result the motor draws a current in the order of its starting current, or slightly above, and this current lasts until speed reaches zero. Because the torque acts in the opposite direction, the shaft decelerates rapidly. If the contactor does not open the moment speed reaches zero, the motor starts up in reverse; that is why plugging must always be cut off by a zero-speed device (a speed monitor, centrifugal switch or encoder input) or by a safely set timer relay.
Rotor heat calculation: where does braking energy go?
The kinetic energy of the rotating system is calculated as E = ½ · J · ω², where J is the total moment of inertia and ω the angular speed (ω = 2π · n / 60). According to classic motor theory, plugging from synchronous speed to standstill releases heat in the rotor of roughly three times this kinetic energy. With DC braking the rotor loss is roughly equal to the kinetic energy itself; a no-load start also puts about the same amount of heat into the rotor. That is a threefold gap.
A hypothetical example: if a circular saw drum with 20 kJ of kinetic energy is stopped by plugging, the rotor takes a heat load of about 60 kJ; if the same drum is stopped with DC braking, the figure stays around 20 kJ. On a machine that brakes thirty times an hour, this difference directly determines the temperature of the rotor bars and winding overhangs. These ratios are general knowledge; confirm them with the machine manufacturer and the control designer.

Feeding direct current into the stator winding: how is DC braking set up?
In DC braking the main contactor opens and, after a short waiting time, a rectified voltage is applied to two terminals of the stator winding (between two phases in a star connection). The rotor spinning inside a stationary field induces currents in its bars and produces a torque that opposes its own rotation. As speed falls the braking torque also changes; its effect weakens at low speed, so a hard hold right down to zero should not be expected.
The waiting time matters: when the motor is disconnected from the mains, the residual magnetism in the rotor keeps generating voltage in the stator for a while. If the DC voltage is applied before this residual voltage has died away, the rectifier and contactor contacts can be damaged. The braking current is usually chosen in the order of the rated current; the exact value and duration should be taken from the instructions of the braking module or drive manufacturer. There is no risk of a reverse start.
Practical steps for braking current and duration
- Note the rated current and the connection (Δ or Y) from the motor nameplate.
- Measure the resistance between two winding terminals; the DC voltage needed for the desired current is roughly U = I · R.
- Set the braking time according to the machine's real stopping time and do not keep it longer than necessary.
- Watch the frame and winding temperature during the first trials; for frequent braking consider PTC thermistor winding protection as an order option.
How is braking done with a frequency inverter drive?
If the motor is driven by a frequency inverter, braking is normally done by the drive. The drive ramps the frequency down, the motor works as a generator and the energy returns to the DC bus; it is then turned into heat in a braking resistor or fed back to the grid through a regenerative unit. Many drives also offer a DC injection parameter for the last few revolutions.
Our three-phase series are suitable for speed control with a frequency inverter; for long periods at low speed with full torque an external fan may be required; if the drive-to-motor cable is long, a dv/dt or sine filter is considered; these conditions are stated when ordering. We explain step by step how to verify braking parameters at first start-up in our article on commissioning and first start-up checks.