Core Loss Test (Loop Test) on an Electric Motor

Core Loss Test (Loop Test) on an Electric Motor

The core loss test (loop test) is a workshop test that magnetises the stator lamination stack of an electric motor to a level close to rated flux using a temporary excitation winding, measures the power the stack absorbs and searches for hot spots with a thermal camera. Its purpose is to establish whether the insulation between laminations is sound, whether the stack was damaged while the old winding was removed, and whether the new winding will sit in a healthy core.

The test shows its real value when repeated before and after stripping: the difference between the two measurements tells you in advance whether a rewind will bring the motor back to its former performance.

Why does lamination stack loss decide the fate of a rewind?

The stator core consists of silicon steel laminations separated from one another by a thin insulating coating, and this coating prevents the alternating flux from driving large eddy currents through the stack. If the interlaminar insulation breaks down at some point, several laminations become short-circuited, a local current loop forms there and that area heats up in operation.

The heating reaches the winding. The slot insulation above the hot spot ages faster, and the motor's no-load current and total losses rise. Even if the rewinder does a perfect job, a coil placed in a damaged stack runs hotter than the old motor at the same load. Serious workshops therefore record the stack before stripping the winding.

How is the number of turns for the excitation winding calculated?

In the test, a heavy cable passed through the stator bore and wrapped around the outside of the frame magnetises the stack like the core of a transformer. The required number of turns is derived from the transformer equation: N = U / (4.44 · f · B · A), where U is the applied voltage, f the supply frequency, B the target flux density and A the net cross-sectional area of the yoke (the section between slot bottom and outer diameter).

The net section is found by multiplying yoke height, stack length and lamination stacking factor. If there are cooling ducts, their length is deducted from the stack length. The target flux density is chosen close to the yoke flux in normal operation; for the exact value, follow the procedure of the test equipment manufacturer or the rewinding workshop. The calculation is general knowledge. Confirm it with the measuring instrument manufacturer's instructions.

Hypothetical calculation example

Consider a stator with a net yoke section of 0.012 m²; let the target flux density be 1.5 T and the frequency 50 Hz. The voltage per turn comes out at 4.44 · 50 · 1.5 · 0.012 ≈ 4 V. If a 230 V source is used in the workshop, about 58 turns are needed. With fewer turns the flux rises, the stack approaches saturation and the measured loss grows misleadingly. With too many turns the flux drops. A faulty area then does not heat up enough.

How is the loop test carried out step by step?

  1. Place the stator frame on an insulating surface and remove the rotor and end shields.
  2. Wind the calculated number of turns through the bore and around the outside of the frame using cable with adequate current capacity; spread the turns as evenly as possible around the circumference.
  3. Verify the actual flux in the stack with a separate search coil (a few turns of thin wire); take readings from this coil, not from the excitation voltage.
  4. Record active power, voltage and current with a power analyser; the measurement should be taken once the flux has stabilised.
  5. Leave the stack energised for a set time (as long as the workshop procedure requires) and scan the slot teeth, yoke and bore surface with a thermal camera.
  6. Divide the total loss by the mass of the stack to obtain the specific loss and compare it with the previous measurement of the same stator.

Keep the search coil separate. The voltage drop in the excitation cable makes the real flux in the stack appear higher than it is. If results are not compared at the same flux value, the figures from before and after stripping cannot be compared with each other.

Three-phase electric motor being prepared for measurement on a workshop test bench
The lamination stack test is carried out on the rewinding shop's test bench with the rotor and end shields removed (representative image).

How do you read a hot spot on the thermal camera?

In a sound stack the surface temperature rises slowly and evenly during the test; small, consistent differences appear between yoke and teeth. An area with interlaminar short circuits, however, heats up noticeably faster than its surroundings and shows up in the image as a narrow band or a single bright spot. The hot spot is usually found at the tip of a slot tooth, in the area of the earlier fault, or at a slot edge that was forced while the winding was being removed.

The acceptance decision takes into account not only the size of the temperature difference but also how fast and how persistently the spot spreads. A slight difference that disappears after a short time is often a surface reflection. A stable, growing spot is real damage. Having the workshop define its own acceptance criterion in writing makes measurements consistent from job to job.

Prices and technical data are on the product pages; choose a model and order online.

How do the burn-off oven and mechanical work damage the stack?

If the temperature in the burn-off oven used to free the old winding from its varnish rises uncontrolled, the insulating coating of the laminations is damaged and the stack loss increases permanently. The same effect occurs when tooth tips are bent while coils are forced out with a chisel or crowbar. The oven temperature should therefore be logged and a second loop test carried out after stripping.

If the damaged area is limited, the laminations can be separated and re-insulated, or burred tooth tips can be carefully cleaned. Repeat the test after every intervention. If a loss increase is seen over a wide area of the stack, replacing the motor is often the safer route than rewinding.

Rewind or replace, depending on the test result?

Test findingLikely interpretationRecommended route
Loss close to previous, no hot spotStack is soundRewinding can proceed
Loss slightly higher, one small spotLocal lamination short circuitLocal repair and retest
Loss clearly higher, several spotsOven or stripping damageStack repair or motor replacement
Mechanical crushing at tooth tipsHistory of rotor rubBearings and air gap must also be checked

In small and medium power ratings, buying a new motor instead of repairing a damaged stack often comes out ahead in terms of both time and risk. For the decision you can compare power, speed and frame options in our electric motor shop.

Example replacement models for motors with stack damage

The pairings below are hypothetical; they must be confirmed by comparison with the existing motor's nameplate, mounting type and connection dimensions.

  • For a 22 kW, 4-pole fan or pump motor, the cast iron 180L-4; 1470 rpm, 400/690 V.
  • For a crusher or compressor drive in the 45 kW class, the 225M-4; rated current 80.2 A.
  • To replace a 75 kW motor whose winding has been renewed several times, the 280S-4; 1486 rpm, rated torque 482 Nm.

The general features of the series to which these models belong are collected on the asynchronous electric motors page.

What are the limits of the loop test and what does safety require?

The test evaluates only the stator stack; it gives no information about the condition of the rotor bars, the bearing housings or the shaft. The excitation winding carries a high current. A voltage is induced in every conductor passing through the stack. So no metal tools should be left in the bore, the test area should be fenced off and the cables monitored for heating. Whatever the result, the measured values should be written on the motor's maintenance card together with the date and the flux value.

When putting a rewound motor back into service after the workshop, monitoring no-load current and winding temperature during the first operating hours catches an overlooked stack problem early. If after the test you decide to replace the motor, share a photo of the existing nameplate and terminal connection via the find an equivalent from the nameplate page; add your stack measurement and we will choose the right counterpart together. Other power steps are listed on the HEM Motor product pages.

Frequently Asked Questions

For which motor sizes is a loop test meaningful?

The test can be done at any size, but it is more decisive in medium and large ratings where rewinding is expensive. For small motors the cost of a new motor usually does not exceed the cost of testing and repair.

Can the result be interpreted if no measurement was taken before stripping?

Yes, but for comparison you need a sound stator of the same type or a reference value from the manufacturer. The hot spot scan with a thermal camera is valuable on its own even without a previous measurement.

Do low-flux electronic core testers replace the loop test?

They help find interlaminar defects and need far less power. To see how total loss behaves at rated flux, however, the classic high-flux test gives a more direct result.

What happens if a motor is rewound while the stack has a hot spot?

The motor will run, but the slot insulation above the hot area ages faster and the same fault may recur sooner. No-load current and losses also stay higher than with a sound stack.

HEM Motor Models Related to This Article

The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.

22 kW 1500 rpm Cast Iron Frame Electric Motor 180L-4

180L-4

22 kW · 1500 rpm

  • Cast iron frame · IEC 180L
  • 1470 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$901.75 (€825.30)

View product
45 kW 1500 rpm Cast Iron Frame Electric Motor 225M-4

225M-4

45 kW · 1500 rpm

  • Cast iron frame · IEC 225M
  • 1485 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$1,656.00 (€1,515.60)

View product
75 kW 1500 rpm Cast Iron Frame Electric Motor 280S-4

280S-4

75 kW · 1500 rpm

  • Cast iron frame · IEC 280S
  • 1486 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$2,860.77 (€2,618.24)

View product

Similar Articles