Workshop Return Acceptance Measurements for an Electric Motor

Workshop Return Acceptance Measurements for an Electric Motor

When an electric motor comes back from the workshop with a new winding, new bearings or a repaired frame, it should pass four measurements before it is fitted to the machine: insulation resistance, phase winding resistance balance, no-load current, and vibration together with bearing temperature. Placed side by side with the values in the workshop's handover report, these readings show on site, before any load is applied, whether the repair has really been completed. If acceptance testing is skipped, the fault usually appears during the first shift, with the machine loaded and at a far more expensive moment.

Which values should the workshop report contain?

The first step of acceptance is not a meter but a sheet of paper. After a rewind or overhaul, the workshop report should include at least the following: phase resistances before and after rewinding with the measuring temperature, the insulation test voltage applied and the value read, the surge test result if one was done, the type of bearings fitted, and the no-load trial current.

If the report does not state that the wire cross-section, coil pitch and number of turns were kept the same as the old winding, ask about it. An electric motor whose turn count has changed by a few turns runs normally at first glance. But its no-load current and heating will be different.

The nameplate values (kW, voltage, connection, speed) must remain legible on the motor. If the plate has been lost, ask the workshop for a re-engraved one.

What should be checked by eye and by hand before measuring?

Before taking any readings, put the motor on the bench and turn the shaft by hand. It should rotate without catching, without rubbing noises and without a noticeable increase in axial play. Look for broken fan blades, a dented fan cover and a torn terminal box gasket. Check that the terminal links are in place and their nuts are tight.

Rust that has been painted over rather than cleaned, missing or mismatched bolts on the end shields, and impact marks on the shaft end are signs that deserve attention. The keyway and key must be sound; if an old coupling half was pulled off in the workshop, make sure the shaft was not damaged during pulling.

How do you read insulation resistance and the polarization index?

Insulation resistance is measured with an insulation tester (megger) that applies DC voltage between the winding and the frame. For low-voltage motors, a test voltage of 500 V or 1000 V DC is commonly used on site. Which one to choose depends on the motor's rated voltage and the instrument manufacturer's instructions. Before testing, the motor is isolated from the supply, the cables are removed from the terminals, and when the test is finished the winding is discharged by earthing it.

A time-based reading says more than a single value. The polarization index (PI) is the ratio of the resistance at the 10th minute to the resistance at the 1st minute:

PI = R(10 min) / R(1 min)

In a dry, clean winding the resistance rises clearly over time. In a damp or dirty winding the curve stays flat. On site, a PI below 2 is usually taken as a sign of moisture or contamination (general information; confirm with the instrument manufacturer's instructions). Because insulation resistance changes strongly with temperature, always note the measuring temperature. The same motor gives a different result straight from a cold store than on a warm bench.

How is phase winding resistance balance measured?

The resistance of the three phase windings is measured with a micro-ohmmeter of milliohm resolution or an instrument using four-wire (Kelvin) measurement. The terminal links are removed and each phase is read at its own leads. A simple multimeter gives an idea on small motors, but on large frames the winding resistance is so low that it falls short.

The imbalance is calculated as follows:

Imbalance (%) = (largest deviation / average of the three phases) × 100

Take a hypothetical example. 0.412 Ω, 0.418 Ω and 0.409 Ω were read on phases U, V and W. The average is 0.413 Ω and the largest deviation from the average is 0.005 Ω; the imbalance comes out at about 1.2%. If this value agrees with the workshop's own measurement it is a good sign.

If one phase stands clearly apart, look for a loose connection, a faulty brazed joint or a difference in turns.

Since resistance varies with temperature, reduce both readings to the same reference temperature before comparing them with the workshop value. The general formula for copper is R₂ = R₁ × (235 + t₂) / (235 + t₁) (general information; confirm with the instrument instructions).

Three-phase electric motor waiting for acceptance measurements on a test bench
An electric motor back from the workshop is measured on the bench before any load is connected (representative image).

How are current, noise and temperature monitored in the no-load trial run?

If the electrical measurements are clean, the motor is run uncoupled at rated voltage and with the connection on the nameplate (Δ or Y). The no-load current of all three phases is read with a clamp meter. The current difference between phases usually looks larger than the winding resistance imbalance, because it also carries the supply voltage imbalance. So measure the phase-to-phase voltages at the same time.

The ratio of no-load current to rated current varies with the motor's number of poles and power; it is higher in small and multi-pole motors. Instead of a fixed threshold, compare with the same motor's no-load current before rewinding or with the value in the workshop report. A no-load current clearly higher than before suggests that the number of turns has been reduced or that there is a problem in the air gap.

While the trial runs for 15–30 minutes, the bearing housings are monitored by hand and with a non-contact thermometer. The temperature should rise smoothly and then settle. A bearing temperature that keeps climbing points to the wrong amount of grease, a tight fit or an end shield fitted out of line.

Prices and technical data are on the product pages; choose a model and order online.

How are vibration and direction of rotation checked?

During the no-load run, vibration is measured at both bearing housings in the horizontal, vertical and axial directions. The motor must stand on a resilient pad or be fixed to a rigid base; a motor sitting loose gives misleadingly high values. Take the readings at the points recommended by the instrument manufacturer and with the same method, so that they can be compared later.

The key in the shaft end must match the half-key method used during balancing; note whether the key was left in place during the no-load trial.

Finally, check the direction of rotation. The phase sequence may have been changed in the workshop. On direction-sensitive machines such as pumps and fans, the direction must be verified before the coupling is connected.

Decision table for acceptance measurements

MeasurementInstrumentWhat to look forIf the finding is suspicious
Insulation resistance and PIInsulation testerRise over time, temperature noteDrying, repeat measurement
Phase winding resistanceMicro-ohmmeterThree-phase balance, agreement with workshop valueCheck connections and joints
No-load currentClamp meterCloseness to old value, phase differenceCompare winding data with the workshop
Bearing temperatureNon-contact thermometerRises and then settlesCheck grease quantity and fit
VibrationVibration meterValues in three directions at both bearingsInspect base, balance, bearings

Repair or a new electric motor?

If acceptance testing produces recurring findings, or the motor is going for its second or third rewind, it makes sense to compare it with a new electric motor. In a motor rewound many times the lamination stack may have been damaged by heat; these losses show up in the measurements as an increase in no-load current. Spare motors are listed by power and frame in our electric motor shop; for spares that will work in vibrating and dusty locations, the cast iron frame electric motors family is also worth a look.

Hypothetically, if a 4-pole line motor is to be replaced, the cast iron 132M-4 for 7.5 kW (1460 rpm, 14.3 A), the aluminium-frame 160M-4 for 11 kW (1465 rpm, 20.4 A) and the cast iron 160L-4 for 15 kW (1465 rpm, 400/690 V) can be compared. The IEC frame number is the first clue to compatibility; mounting type, shaft, foot holes and flange are checked against the technical drawings.

A new motor should go through the same set of measurements at commissioning; these first values become the reference point for the next time the motor comes back from the workshop. For the first start-up steps, see the commissioning checklist.

Filing the acceptance record

The value of the measurements grows with how well they can be compared with the next set. For each motor, prepare a one-page record containing the date, ambient temperature, insulation value and PI, the three phase resistances, no-load currents, vibration values and the name of the person who measured. If you give the motor an inventory number on its frame and keep the record under that number, you will be able to see the trend when the same motor goes back to the workshop years later.

If the repair is not economical or the measurements are borderline, share the measurement record together with the existing motor's nameplate through the find an equivalent from the nameplate page; we will review the values and discuss the model that can take its place. Other options by power and frame can be seen in the HEM Motor product list.

Frequently Asked Questions

Insulation resistance is high but the PI is low; can the motor be used?

A high one-minute value may only reflect a dry surface, while a low PI suggests there may be moisture or dirt inside the winding. Drying the motor, measuring again at the same temperature and sharing the result with the workshop is the safest route.

The phase resistances are balanced but the no-load current is higher than before; why?

Winding all three phases differently (a change in turns or connection) can raise the current without upsetting the balance. Heat damage to the lamination stack gives the same result; ask the workshop for the winding data.

Can acceptance measurements be done while the motor is connected to the machine?

Insulation and resistance measurements can be done with the cables disconnected from the terminals. No-load current and vibration, however, must be measured with the coupling removed and no load; otherwise the machine's influence mixes with the motor's.

How long does it take for the temperature to settle after a bearing change?

With freshly greased bearings, the temperature rises somewhat in the first minutes, then falls and settles. If you see a steady increase lasting more than half an hour, stop the motor and have the grease quantity and end shield seating checked.

HEM Motor Models Related to This Article

The cards show example models related to the topic. A suitable motor is not chosen by power alone: compare speed, voltage, mounting, shaft and connection dimensions on the product page; if unsure, send a photo of the existing motor’s nameplate on WhatsApp.

7.5 kW 1500 rpm Cast Iron Frame Electric Motor 132M-4

132M-4

7.5 kW · 1500 rpm

  • Cast iron frame · IEC 132M
  • 1460 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$387.29 (€354.46)

View product
11 kW 1500 rpm Aluminium Frame Electric Motor 160M-4

160M-4

11 kW · 1500 rpm

  • Aluminium frame · IEC 160M
  • 1465 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$532.46 (€487.32)

View product
15 kW 1500 rpm Cast Iron Frame Electric Motor 160L-4

160L-4

15 kW · 1500 rpm

  • Cast iron frame · IEC 160L
  • 1465 rpm · IP55
  • Mounting: B3 foot; flange (B5/B14/B35) depending on frame, confirmed with the order

US$665.08 (€608.69)

View product

Similar Articles