If you are researching the 132 kW electric motor price and ready-stock sales options for your high-power drive systems, you are in the right place. At HEM Motor we supply 132 kW three-phase asynchronous motors usually in a 315 frame size; in 2-pole (3000 rpm) and 4-pole (1500 rpm) options, in IE3 and IE4 efficiency classes. For a motor of this size, ready-stock sales means both a clear price-performance balance and a planned delivery. In this article we share pole-speed selection, efficiency class, high-power starting and the fast quotation process in detail.

132 kW is one of the heavy drive steps for large centrifugal pumps, main-line compressors, crushing-screening plants and high-capacity fan systems. Motor selection at this rating directly concerns project items such as starting, shipping, commissioning and spare planning. To clarify the right configuration and stock status, reach us through the HEM Motor electric motor prices page and request a fast quotation by sharing your requirement.

When buying a high-power motor, the label rating alone is not a sufficient criterion. The real value of a 132 kW motor emerges through its pole count, efficiency class, winding quality, bearing choice and mounting type. Working with the ready-stock sales advantage lets you configure these details correctly and reach the most suitable configuration without unnecessary intermediate cost. In the sections below we share a roadmap for selecting the right 132 kW motor.

Large grey 132 kW electric motor

Pole, Speed and Torque Relationship in a 132 kW Motor

Speed selection in a 132 kW motor is determined by your drive's torque and speed needs. A 2-pole 132 kW motor offers high speed around 3000 rpm and is preferred in large centrifugal pumps and high-flow turbo compressors. A 4-pole 132 kW motor at 1500 rpm delivers higher starting torque and is common in conveyors, crushers, mixers and large fan systems. The speed choice directly affects frame weight, cooling need and therefore the price-performance balance.

Pole / SpeedTypical ApplicationKey Feature
2-pole (3000 rpm)Large centrifugal pump, turbo compressorHigh speed, high flow capacity
4-pole (1500 rpm)Conveyor, crusher, large fan, mixerHigh starting torque, balanced running
6-pole (1000 rpm)Heavy drive, low-speed processHigh torque, gearless option

If you are unsure which speed suits your drive, simply share the speed value on your machine nameplate. For more, see our 90-132 kW high-power 2/4-pole selection guide and our 160 and 200 kW high-power motor supply article.

Efficiency Class at 132 kW: IE3 vs IE4

At high powers like 132 kW, the efficiency class is the most important item directly determining the motor's annual energy bill. IE3 is the minimum standard in this band; however, in continuous processes running long hours per day, the IE4 super premium efficiency class quickly pays for itself through the difference in energy cost. As HEM Motor, we can supply both our IE3 electric motors and IE4 electric motors from stock.

  • IE3 premium efficiency: A balanced price-performance start for medium-intensity plants.
  • IE4 super premium efficiency: Markedly lowers total cost of ownership in three-shift and continuous processes.
  • Copper winding, F/H insulation: At high powers like 132 kW, winding and insulation quality determine hot-ambient endurance and life.

To see the efficiency class impact on the investment decision, we recommend our part-load efficiency curve article and the general electric motors category.

Large grey 132 kW electric motor

High-Power Starting: Softstarter and VFD

At 132 kW, direct-on-line (DOL) starting is not preferred in most plants due to the high inrush current. In this power band, a soft starter or variable frequency drive (VFD) is almost a standard requirement. Correct starting both protects the grid and transformer and extends motor and coupling life by reducing mechanical stress.

Starting MethodSuitable ApplicationAdvantage
SoftstarterLarge pump, fan, compressorLimits inrush, shock-free start
VFD (frequency inverter)Variable-flow pump and fanSpeed control and energy saving
Automatic star-deltaHeavy drives starting unloadedClassic and economical solution

In VFD operation at high powers, bearing current, grounding and winding insulation gain importance. On this topic we recommend our motor protection and thermal relay selection article and, for commissioning planning, the high-power supply guide.

Mounting Type, Weight and Shipping Planning

A 132 kW motor requires careful planning for mounting and shipping due to its frame size and weight. The foot-mounted (B3) frame is fixed to the floor, while the flange-mounted (B5) frame is used in pump and reducer connections; B35 combines both. At this rating the motor is usually shipped on a pallet or in a crate, lifted by crane using lifting eyebolts.

  • B3 foot mounting: Fixed floor mounting for large conveyors, crushers and fan systems.
  • B5 flange mounting: Connects directly to a pump or reducer body with axial precision.
  • B35 foot + flange: Combines both mounting options; provides flexibility in replacement orders.

To compare mounting types, review our B5 flange electric motors and B3 mounted electric motors pages. By planning the shipping and commissioning of the heavy motor together, we eliminate surprise delays.

Large red 132 kW electric motor on a pallet in the warehouse

Where the 132 kW Motor Is Most Used

The 132 kW band appears in the large drives forming the backbone of heavy industry. Motor selection at this rating requires accounting not only for power but also for duty type, ambient temperature and continuous/intermittent operating regime.

Sector / ApplicationTypical DrivePriority Feature
Water and wastewaterLarge lift and distribution pumpHigh efficiency in continuous running
Mining and aggregateCrusher, screen, main belt conveyorHigh torque, robust bearings
Compressed airLarge screw compressorThermal endurance under continuous load
Industrial fanForced-draft and exhaust fansLow vibration, balanced running

To see options for your application, review our pump electric motors, compressor electric motors and stone crushing plant motors pages.

Ready-Stock Sales and Fast Quotation Process

Our biggest advantage in 132 kW motors is the planned ready-stock sales model. We supply the most demanded 2- and 4-pole configurations with B3/B5/B35 mounting options. You can view standard-frame high-power motor options on our standard electric motors page.

The most common problem in high-power motor purchasing is the unexpected supply delay that appears in the middle of the project. To minimise this risk, we plan the most demanded configurations in advance at critical ratings like 132 kW and also raise the value of keeping a spare motor for critical production lines; a line stoppage often costs far more than the motor itself.

To define your need, three pieces of information are enough: power (132 kW), speed/pole and mounting type (B3, B5 or B35). With these three headings we offer you the most accurate price-performance recommendation and a fast quotation. Simply contact us for current electric motor prices and stock status.

Frequently Asked Questions

What determines the 132 kW electric motor price?

Pole count (speed), efficiency class (IE3/IE4), mounting type and requested options are the main factors. In ready-stock sales, with no intermediary cost, the price-performance balance is often more favourable.

What is the delivery time for a 132 kW motor?

We supply the most demanded 2- and 4-pole configurations on a planned basis. If the configuration is ready, delivery is fast; special options and shipping details are clarified during the fast quotation stage.

Is it sensible to move to IE4 in a 132 kW motor?

If your daily operating hours are high and continuous, IE4 super premium efficiency pays for itself quickly through the difference in energy cost. For medium-intensity plants, IE3 is a balanced choice.

Which frame size is used for a 132 kW motor?

132 kW motors are typically built in a 315 frame size. The frame detail may change with speed and efficiency class; for a correct replacement the existing motor's nameplate data is enough.

Does a 132 kW motor need a softstarter or a VFD?

A softstarter is recommended for constant-speed pumps, fans and compressors; a VFD for applications requiring variable flow. We determine the most suitable starting method for your application together during the fast quotation process.

To source the right 132 kW motor for your high-power drive at the best price-performance from stock, contact the HEM Motor team; send us your requirement and let us prepare a tailored fast quotation.